Laserfiche WebLink
Typical of AC-F1 <br />EC <br />1 <br />A1 <br />A2 <br />E <br />C <br />S1 <br />S2 <br />D <br />C <br />R <br />Rc <br />Y <br />W <br />G <br />ACT <br />AUX <br />ENA <br />COM <br />POS <br />EXT <br />T1 T2T3SAT (T1) <br />RAT (T2) <br />OAT (T3) <br />DATA <br />COM <br />PWR <br />Pearl Economizer <br />Controller <br />2 <br />3 To Economizer <br />Actuator <br />To Return Air Sensor <br />Y <br />O <br />G <br />To Conventional Unit <br />Thermostat Connections <br />To Supply Air Sensor <br />To Outside Air Sensor <br />ZC <br />1 <br />TS250 <br />Conventional Unit <br />R RC O/BC YGCD Aux <br />C C <br />W2 <br />Y2 <br />AUX <br />Y2 <br />SAOA <br />RA <br />R O/B W2 <br />Au/E Y GY2 <br />GY2YAux/EW2WRCConventional Unit <br />To Pearl <br />Thermostat <br />Connections <br />DA <br />1 <br />1 <br />2 <br />3Pearl Controller A1 <br />24VAC <br />24H <br />RC/C XXXXTo T1 TerminalsSA <br />1 <br />XXXXTo T3 TerminalsOA <br />1 <br />XX <br />XX <br />To T2 TerminalsRA <br />1 <br />TYP. OF KEF-A1 <br />EA <br />24VAC <br />D <br />CS <br />1 <br />SPLIT SYSTEM AC <br />UNIT UTY-TTRX <br />INTERFACE <br />BOARD <br />BY OTHERS <br />VFD <br />NOTE: EXISTING AC-UNIT THERMOSTAT MUST BE <br />CONFIGURED TO TURN ON WHEN KEF-A1 IS ON.L1 L3L2 <br />208VAC,3Ø <br />EA <br />BY <br />OTHERS <br />TC <br />C <br />TR <br />R <br />G3 <br />G2 <br />G1 <br />TC <br />1 TS250 <br />Y1 <br />Y2 <br />Y3 <br />Y2 <br />Y1 <br />W2 <br />W1 <br />G <br />WIRING TO BE <br />DETERMINED BY <br />INSTALLER <br />W/B <br />W/Y <br />RC W1 W2 Y1 Y2 G <br />RIB <br />1 <br />OrnR1-1 <br />R1 <br />Yel 120VAC POWER <br />46W 1PH <br />C R RC W W2 Y Y2 G <br />Conventional <br />No practical limits to the number of <br />Thermostats that can be supported by a <br />Gateway. Multiple Gateways can be used <br />to support a site. <br />INTERLOCK UNITS SHPI-A1 & <br />SHPI-A3 WITH CEF-A1 <br />CEF-A1 <br />TA1 Sensor, <br />With External Dry Contact <br />D C <br />24VAC Power <br />24VAC Common <br />R <br />C <br />D <br />Dry Input <br />T <br />T <br />Pelican <br />Wireless Systems <br />TS-1 <br />TAG QTY <br />X <br />RC W1 W2 Y1 Y2 G Unit Terminal Board <br />R RC W1 W2 Y1 Y2 G <br />TO FUJITSU <br />INDOOR UNIT <br />WIRELESS COMPONENTS <br />PEL TS250 Wireless Thermostat <br />PART NUMBER DESCRIPTION <br />FIELD COMPONENTS <br />WIRELESS COMPONENTS <br />TAG QTY <br />TA1 <br />PART NUMBER <br />X PEL TA1 <br />DESCRIPTION <br />SENSOR WITH EXTERNAL DRY CONTACT <br />FIELD COMPONENTS <br />TAG QTY <br />CS-1 <br />PART NUMBER <br />X FUN RIBXGTF CURRENT SENSOR <br />DESCRIPTION <br />TAG QTY <br />RIB-1 <br />PART NUMBER <br />X FUN RIBU1C <br />DESCRIPTION <br />24 VAC, SPDT RIB RELAY, 10A CONTACT RATING <br />CP-X <br />1. CIRCULATING PUMP SHALL RUN DURING OCCUPIED HOURS. <br />2. SET AQUASTAT TO SHUT OFF PUMP WHEN RETURN WATER <br />TEMPERATURE REACHES 140 DEG F. <br />3. SEE PLUMBING PLANS FOR LOCATION. <br />120 VAC <br />BY E.C. <br />AQUASTAT <br />RIB-1 <br />BLK <br />24 <br />WHT <br />TO PELICAN <br />DEVICE <br />RA SADX <br />C <br />SAOA <br />CT Relay <br />W/ CO2 <br />W/ CO2 <br />W/ CO2 <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XXKITCHEN RENOVATIONJOE SERNA SCHOOLSHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />12/11/2019 <br />REVISIONS BY <br />19-32-050 <br />RL <br />TD <br />FILE NO. 39-50 APP NO. 02- <br />XX <br />AS NOTED <br />L:\2019\191009.00\1200 Drawings\1205 AutoCAD Project Files\M6.2.dwg - December 12, 2019 06:06 PM - Richard LingoM6.2 MECHANICAL CONTROLS