TEACHERS ROOM <br />JAN/ <br />STOR <br />STAFF <br />TOILET <br />KITCHEN <br />FREEZERCOOLER <br />FOOD <br />LOCKER COMP. & <br />W.H. <br />MULTI-PURPOSE <br />ROOM <br />STAGESTAGE <br />MECHANICAL COMP. <br />RM. <br />FOR DEMO WORK IN <br />THIS AREA, <br />SEE 2 <br />P2.1 <br />1 <br />P2.2 <br />AC/1GG CD <br />(E)4"W <br />FOR DEMO WORK IN <br />THIS AREA, <br />SEE <br />(E)4"W (E)1 1/2" CW <br />1 <br />P1.1 <br />(E)1 1/2" CW <br />1 <br />P1.1 <br />(E)1 1/2" G <br />1 <br />P1.1 <br />(E)1 1/2" CW <br />TEACHERS ROOM <br />JAN/ <br />STORSTAFF <br />TOILET <br />KITCHEN <br />FREEZER <br />COOLER <br />FOOD <br />LOCKER <br />COMP. & <br />W.H. <br />MULTI-PURPOSE <br />ROOM <br />G G <br />(E) 4"VTR <br />(E) 4"W <br />(E) 1 1/2" VTR <br />(E) 1 1/2" G <br />(E) 1 1/4" G <br />BELOW FLOOR <br />(E) 3/4" G,R <br />TO OVEN <br />VALVE <br />(E) 2" VTR <br />(E) 2" VTR <br />(E) 1 1/4" CW <br />(E)1/2" CW <br />(E)FD <br />(E)FD <br />(E)FD <br />(E)FD <br />(E)COTG <br />(E) DISH <br />WASHER <br />(E)FD <br />(E) 2" VTR <br />(E) 3" W(E) 3" W <br />(E) 1 1/4" CW <br />(E) 1/2"HW <br />(E) 3/4" HW <br />(E) DISPOSAL(E) GREASE <br />TRAP <br />1 <br />P1.1 <br />1 <br />P1.1 <br />(E) 1 1/4" VTR <br />(E) 1 1/2" VTR <br />(E) 3/4"HW <br />(E) PIPING IN ATTIC <br />(E) 1 1/2"CW <br />(E) 1"HW <br />(E) 2"V <br />(E) 3"W <br />(E) CAN WASHER <br />1 <br />P1.1(E) 1/2" H&CW PIPING <br />BELOW GRADE <br />(E) 1/2" H&CW PIPING <br />IN ATTIC SPACE <br />(E) 1 1/4"G <br />TO (E)WH. <br />(E) 1 1/4"G <br />(E) 1 1/2"CW <br />(E)HB <br />(E) PIPING <br />IN FURRING <br />(E) HW PIPING <br />BELOW FLOOR <br />(E) 1 1/2" CW,R <br />(E) PIPING <br />IN ATTIC <br />(E) GAS <br />RANGE <br />1 <br />(E)4"SS <br />(E) SINK TO <br />REMAIN <br />4 1 <br />3 <br />7 <br />6 <br />2 <br />2 <br />3 <br />6 <br />3 <br />6 <br />1 2 <br />3 <br />3 <br />2 <br />(E) DF <br />RELOCATE <br />3 FOR NEW DF LOCATION. <br />COORDINATE AMONGST <br />TRADES <br />DEMO SHEET NOTES: <br />1.EXISTING PLUMBING LAYOUT BASED FROM AVAILABLE <br />RECORD DRAWINGS OF UNKNOWN ACCURACY. <br />EXISTING PIPING ESPECIALLY THOSE CONCEALED <br />AND/OR UNDERGROUND MAY HAVE BEEN INSTALLED <br />DIFFERENTLY THAN SHOWN HEREWITH. CONTRACTOR <br />SHALL INVESTIGATE EXISTING PIPE ROUTE, ELEVATION, <br />SIZE AND CONDITION, THRU VISUAL OBSERVATIONS, <br />POT-HOLING, RADAR INSPECTION OR OTHER MEANS <br />NECESSARY, PRIOR TO ANY NEW PIPE INSTALLATION. <br />REFLECT ALL FINDINGS ON SHOP DRAWINGS FOR <br />COORDINATION AMONGST TRADES. REFLECT EXISTING <br />ROUTE, ELEVATION AND OTHER OBSERVATIONS ON <br />AS-BUILT DRAWING IF DIFFERENT FROM SHOWN <br />HEREWITH. <br />2.CONTRACTOR TO REMOVE ALL PIPING NOT <br />CONNECTED TO PLUMBING FIXTURES. REFLECT ON <br />AS-BUILT DRAWINGS. <br />3.CONTRACTOR SHALL REFLECT EXISTING AND/OR <br />ABANDONED PIPING ON THE AS-BUILT DRAWINGS IF <br />FOUND DIFFERENTLY FROM DESIGN PLANS FOR <br />OWNER'S REFERENCE AND RECORD KEEPING. <br />4.PATCH ALL UNUSED ROOF PENETRATIONS TO MATCH <br />EXISTING. SEE ARCHITECTURAL DRAWINGS FOR MORE <br />INFORMATION. <br />5.PROVIDE SLAB DEMOLITION WORK AS NECESSARY TO <br />REMOVE, REPLACE, REROUTE OR ADD UNDERGROUND <br />PIPING. PATCH BACK TO MATCH SURROUNDING <br />FLOOR/PAVEMENT. <br />PROVIDE TEMPORARY CAP ON (E) PIPING. PREPARE FOR <br />RECONNECTION TO NEW PIPE <br />VERIFY EXACT SIZE AND LOCATION OF EXISTING PIPE. <br />REFLECT VERIFIED INFORMATION ON SHOP DRAWINGS FOR <br />COORDINATION AMONGST TRADES PRIOR TO ANY PIPE <br />INSTALLATION. REFLECT ON AS-BUILT DRAWING IF <br />DIFFERENT FROM HEREWITH. <br />VERIFY EXACT LOCATION OF ALL BUILDING COMPONENTS <br />THAT MAY OBSTRUCT PATH OF NEW PIPING. REFLECT <br />VERIFIED INFORMATION ON SHOP DRAWINGS FOR <br />COORDINATION AMONGST TRADES PRIOR TO ANY PIPE <br />INSTALLATION. REROUTE PIPING IF REQUIRED, REFLECT <br />ON AS-BUILT DRAWINGS IF DIFFERENT FROM HEREWITH. <br />SEE PLUMBING SHEET P2.2 FOR NEW PIPING. <br />PROTECT FIXTURE TO REMAIN IN PLACE DURING <br />DEMO/CONSTRUCTION WORK. PROVIDE TEMPORARY <br />UTILITIES WHEN NEEDED. COORDINATE SERVICE <br />INTERRUPTIONS WITH SCHOOL DISTRICT. <br />REMOVE EXISTING PLUMBING FIXTURE/EQUIPMENT. <br />UNLESS SHOWN OTHERWISE, CAP UNUSED PIPING ABOVE, <br />BELOW OR BEHIND ARCHITECTURAL FINISHES. SEE <br />ARCHITECTURAL SHEETS FOR MORE INFORMATION <br />REMOVE ALL UNUSED EXISTING WASTE, VENT, WATER, <br />CONDENSATE DRAIN & GAS PIPING ABOVE GROUND WITHIN <br />WORK AREA. CAP BEHIND ARCHITECTURAL FINISH. <br />CAREFULLY REMOVE AND SALVAGE EXISTING DRINKING <br />FOUNTAIN WITH BOTTLE FILLER FOR REINSTALLATION AT A <br />DIFFERENT LOCATION. <br />REMOVE (E) VTR. PATCH ROOF TO MATCH EXISTING. SEE <br />1 <br />DEMO KEYNOTES: <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />SHEETSOF730 Howe Avenue, Suite 450Sacramento, CA 95825Phone: 916.921.2112Fax: 916.921.2212XXKITCHEN RENOVATIONJOE SERNA SCHOOLSHEET NO. <br />CONSULTANT <br />UPDATED <br />CADFILE <br />CHECKED <br />DRAWN <br />SCALE <br />PROJECT NO. <br />DATE <br />12/11/2019 <br />REVISIONS BY <br />19-32-050 <br />RL <br />TD <br />FILE NO. 39-50 APP NO. 02- <br />XX <br />AS NOTED <br />191009.00 <br />PM - DESIGN TEAM PROJECT NO. <br />MCM - RL/SL <br />C A <br />RANCHO CORDOVA,CALIFORNIA <br />ENGINEERING CONSULTANTS, INC. <br />P I T A L <br />\\capsac.lan\network\Project_Docs\2019\191009.00\1200 Drawings\1205 AutoCAD Project Files\P2.1.dwg - December 12, 2019 03:15 AM - Joel ValenciaP2.1 PLUMBING FLOOR PLAN &DEMO FLOOR PLAN