FREEJOINTATTACHEDJOINTCROSS RUNNERSTYP.BRACINGWIRELOCATION-TYP.STABILIZER BARS,CROSS TEES ORSTRUTS 8" MAX. FROMWALL TYP. ALONG FREEJOINTS CONT ANGLE @PERIMETERFREEJOINTNOTEMAINRUNNERS2.604'-0"MAX8'-0"MAX4'-0"MAX4'-0" <br />MAX <br />8'-0" <br />MAX <br />ATTACHEDJOINT2.602.60ATTACHEDJOINT4'-0" <br />MAX <br />64 SQ FTMAX2.60FREEJOINTTypical2.35[WHERE A PROPRIETARYSEISMIC CLIP IS SPECIFIED,RDP TO REMOVE THESTABILIZER BARS SHOWNON THE PLAN AND THEABOVE STABILIZER BARNOTE]BRACING WIRES AND COMP. STRUT SHALL OCCURAT EVERY 64 SQ. FT. MAX. IN ROOMS OVER 144 SQ.FT.FREEJOINTATTACHED JOINTCROSS RUNNERSTYP.BRACINGWIRELOCATION-TYP.CONT ANGLE @ PERIMETERNOTEMAINRUNNERS2.602.60STABILIZER BARS,CROSS TEES ORSTRUTS 8" MAX.FROM WALL TYP.ALONG FREE JOINTS96 SQFTMAX4'-0"MAX8'-0"MAX4'-0"MAXATTACHED JOINT6'-0" <br />MAX <br />12'-0" <br />MAX <br />6'-0" <br />MAX <br />FREEJOINT2.60FREEJOINT2.60ATTACHED JOINTTypical2.35[WHERE A PROPRIETARYSEISMIC CLIP IS SPECIFIED,RDP TO REMOVE THESTABILIZER BARS SHOWNON THE PLAN AND THEABOVE STABILIZER BARNOTE]BRACING WIRES AND COMP. STRUT SHALL OCCUR ATEVERY 96 SQ. FT. MAX. IN ROOMS OVER 144 SQ. FT.FREEJOINTATTACHEDJOINTCROSS RUNNERSTYP.BRACINGWIRELOCATION-TYP.CONT ANGLE @ PERIMETERNOTEMAINRUNNERS6'-0"MAX12'-0"MAX6'-0"MAX6'-0" <br />MAX <br />12'-0" <br />MAX <br />6'-0" <br />MAX <br />2.602.60ATTACHEDJOINTFREEJOINT2.60FREEJOINT2.60ATTACHEDJOINT144 SQFT MAXTypical2.35BRACING WIRES AND COMP. STRUT SHALL OCCUR AT EVERY 144SQ. FT. MAX. IN ROOMS OVER 144 SQ. FT.2.602.602.402.40EXPANSIONJOINTATTACHED JOINTFREEJOINTATTACHEDJOINTATTACHED JOINTCONNECTED TOWALLLOCATION OF EXPANSION/SLIP JOINTS INCORRIDORSO.H.12'-0" MAX (TYP)"L/2" MAX"L/2" MAX.FREE JOINT4'-0" MAX.(TYP.)"L" MAX.(TYP)TYPICALSTRUT ANDBRACING2.35NOTES:STABILIZER BARS, CROSS TEES OR STRUTS8" MAX. FROM WALL TYP. ALONG FREEJOINTS[WHERE A PROPRIETARY SEISMIC CLIP ISSPECIFIED, RDP TO REMOVE THESTABILIZER BARS SHOWN ON THE PLANAND THE ABOVE STABILIZER BAR NOTE]************* <br />** <br />* <br />* <br />* <br />*1."L"IS MAX. BRACE ASSEMBLY SPACING PER CEILING PLANDETAIL, FOR EXAMPLE, WHERE 8' x 12' SPACING IS SPECIFIED,USE "L" = 8'.FREEJOINTFREEJOINT[IF THE "ATTACHED JOINT" WALLS AREDESIGNED TO RESIST PERPENDICULARLATERAL LOAD FROM THE CEILING, THERDP SHALL REMOVE THE STRUTBRACING ONLY IN THE DIRECTIONPERPENDICULAR TO THE CORRIDORMARKED WITH AN ASTERISK (*) ANDALSO THE ASTERISK (*) FROM THE PLAN,OTHERWISE REMOVE ONLY THEASTERISK (*).]2.502.502.412.41EXPANSIONJOINTATTACHED JOINTFREEJOINTATTACHEDJOINTATTACHED JOINTCONNECTED TOWALL12'-0" MAX (TYP)4'-0" MAX4'-0" MAXFREE JOINT4'-0" MAX(TYP)8'-0" MAX(TYP)STRUTANDBRACINGTYP.2.352.60@ NON-EXITWAYS@EXITWAYS@ EXITWAYS2.60@ NON-EXITWAYS** <br />* <br />*****************STABILIZER BARS, CROSS TEES OR STRUTS8" MAX. FROM WALL TYP. ALONG FREEJOINTS AT NON-EXITWAYS.[AT NON-EXITWAYS WHERE A PROPRIETARYSEISMIC CLIP IS SPECIFIED, RDP TOREMOVE THE STABILIZER BARS SHOWN ONTHE PLAN AND THE ABOVE STABILIZER BARNOTE][IF THE "ATTACHED JOINT" WALLS ARE DESIGNED TORESIST PERPENDICULAR LATERAL LOAD FROM THECEILING, THE RDP SHALL REMOVE THE STRUT BRACINGONLY IN THE DIRECTION PERPENDICULAR TO THECORRIDOR MARKED WITH AN ASTERISK (*) AND ALSO THEASTERISK (*) FROM THE PLAN, OTHERWISE REMOVE ONLYTHE ASTERISK (*).]FREEJOINTFREEJOINTLOCATION OFEXPANSION/SLIP JOINTSIN CORRIDORS3.103.204.10STRUTS SHALL NOT REPLACE HANGER WIRES.THE MINIMUM ACCEPTABLE ANGLE IS DETERMINED SUCH THATTHE WIRES DO NOT INTERFERE WITH THE RUNNERS, LIGHTFIXTURES, ETC. AND REMAIN STRAIGHT AND UNOBSTRUCTED.NOTESOR4.1012 GA VERTICAL HANGERS AT4'-0" O.C. EACH WAY AT MAINRUNNER WITH MINIMUM 3-TIGHT TURNS IN 3" AT BOTHENDS, SEE12 GA. BRACING WIREW/MIN. 4-TIGHT TURNS IN 11/2" BOTH ENDS OF WIRECONNECTED TO MAINRUNNERS 90º APART, 4-TOTAL AT EACH STRUT(U.N.O.) SEESEE DETAIL 3.10 & 3.20FOR LOCATION OFBRACING WIRES ANDSTRUT MAINRUNNERCROSSRUNNER1..6 MIN10° TO 45°(NOTE 2)2'-0" TYP4'-0"2' <br />-0 <br />" <br /> TYP2.RIGID VERT.STRUT SEEDET.STEEL POPRIVETSTEEL POP RIVETCONT. RUNNERS(SPLICE ALLJOINTS)TYP. HANGERWIRES @ 4'-0"O.C.EXPANSION JOINT ALTERNATE8" MAX.8" MAX.COVER PLATE WITH 1"FLEXIBILITY MINIMUM INALL DIRECTIONS1" CLEAR(SEE NOTE 1BELOW)(SEE NOTE 1BELOW)POP RIVET @EACH RUNNER(TYP.)STEEL POP RIVETWALL MOULDINGHANGERWIRE @EACHRUNNER8" MAX.8" MAX.CONTINUOS WALL MOULDING1" CLEAR(SEE NOTE 1BELOW)(SEE NOTE 1BELOW)EXPOSEDCEILING TEESFIELD CUT TOLENGTHSPLICE WALLMOULDING BYCLIPPINGHORIZONTAL LEG,LAP VERTICAL LEG& INSTALL (3)- #8SMS (TYP.)EXPANSION JOINTEXPANSION JOINTS AT THE INTERSECTION OFCORRIDORS AND AT JUNCTIONS OF CORRIDORS ANDLOBBIES OR OTHER SIMILAR AREASNOTES:1.PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSSRUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH(1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR THEPERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIREDWHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS.TYPICAL SPLICE @CROSS RUNNERSTYP.HANGERWIRES@ 4'-0"O.C.RUNNER SPLICEMAINRUNNERCROSSRUNNERSTEEL POPRIVETSTEEL POP RIVETCONT. RUNNERS(SPLICE ALLJOINTS)TYP. HANGERWIRES @ 4'-0"O.C.EXPANSION JOINT8" MAX.8" MAX.COVER PLATE WITH 1"FLEXIBILITY MINIMUM INALL DIRECTIONS1" CLEAR(SEE NOTE 1BELOW)(SEE NOTE 1BELOW)EXPANSION JOINTS AT THE INTERSECTION OFCORRIDORS AND AT JUNCTIONS OF CORRIDORS ANDLOBBIES OR OTHER SIMILAR AREASNOTES:1. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAINAND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORTOR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE,WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA.PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OF THEEND TEE IS EIGHT (8) INCHES OR LESS.SEISMIC SEPARATION JOINTSTEEL POPRIVETSTEEL POP RIVETCONT. RUNNERS(SPLICE ALLJOINTS)TYP. HANGERWIRES @ 4'-0"O.C.8" MAX.8" MAX.COVER PLATE WITH 1"FLEXIBILITY MINIMUM INALL DIRECTIONS1" CLEAR(SEE NOTE 1BELOW)(SEE NOTE 1BELOW)POP RIVET @EACH RUNNER(TYP.)STEEL POP RIVETWALL MOULDINGHANGERWIRE @EACHRUNNER8" MAX.8" MAX.CONTINUOS WALL MOULDING1" CLEAR(SEE NOTE 1BELOW)(SEE NOTE 1BELOW)EXPOSEDCEILING TEESFIELD CUT TOLENGTHSPLICE WALLMOULDING BYCLIPPINGHORIZONTAL LEG,LAPVERTICAL LEG &INSTALL (3)- #8 SMS(TYP.)ALTERNATE SEISMIC SEPARATION JOINTNOTES:1.PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHINEIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE ENDTEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARENOT REQUIRED WHEN THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS.SEISMIC SEPARATION JOINT AT CONTINUOUS CEILING AREASEXCEEDING 2500 SQ. FT. SEE CEILING PLANS FOR LOCATION13INTERIOR DETAILSA8.3SHEETSOF730 Howe Avenue, Suite 450 <br />Sacramento, CA 95825 <br />Phone: 916.921.2112 <br />Fax: 916.921.221271KITCHEN RENOVATION <br />HOUSTON (SERNA) SCHOOLSHEET NO.CONSULTANTUPDATEDCADFILECHECKEDDRAWNSCALEPROJECT NO. DATE04/10/2020REVISIONSBY19-32-050SLHSLHFILE NO. 39-50 APP NO. 02-1180412.10SCALE: 1/8" = 1'-0"TYPICAL CEILING PLAN FOR 8' X 8' BRACE ASSEMBLY SPACINGSCALE: 1/8" = 1'-0"TYPICAL CEILING PLAN FOR 8' X 12' BRACE ASSEMBLY SPACING2.11SCALE: N.T.SSUSPENDED ACOUSTICAL CEILING-CORRIDOR CEILING PLAN (SCHOOLS)2.30SCALE: 1/8" = 1'-0"TYPICAL CEILING PLAN FOR 12' X 12' BRACE ASSEMBLY SPACING2.12(ESSENTIAL SERVICE BUILDINGS)SUSPENDED ACOUSTICAL CEILING-CORRIDOR CEILING PLANSCALE: N.T.S2.31SCALE: N.T.S.SUSPENDED CEILING - SUSPENSION AND BRACING ASSEMBLY2.35SCALE: N.T.S.SUSPENDED ACOUSTICAL CEILING - EXPANSION JOINT AT INTERSECTIONS2.40SUSPENDED ACOUSTICAL CEILING - EXPANSION JOINT AT INTERSECTIONS(ESSENTIAL SERVICE BUILDINGS)SCALE: N.T.S2.41SCALE: N.T.S.SUSPENDED ACOUSTICAL CEILING - SEISMIC SEPARATION JOINT2.451.CEILING SYSTEM GENERAL NOTES:1.01 Ceiling system components shall complywith ASTM C635-07 and Section 5.1 of ASTME580-10a.1.02 The ceiling grid system must be rated heavyduty as defined by ASTM C635-08.1.03 Ceiling systems. The following ceilingsystem(s) is/are part of the scope of this project:Manufacturer's Name: Certainteed Ceilings.Product Evaluation Report Type and Number:ICC-ES Evaluation Report ESR-3336.Manufacturer's Model Number - Main Runners:9/16" Elite Narrow Stab System-ES 12-12-1915/16" Classic Stab System-CS 12-12-20Manufacturer's catalog number - Cross Runners:9/16" Elite Narrow Stab System-ES 2-12-19-ES 4-12-1915/16" Classic Stab System-CS 2-12-20-CS 4-12-201.04 Seismic Wall Clip: Manufacturer's ModelNumber CertainteedCTSPC-21.05 Ceiling panels shall not support any lightfixtures, air terminals or devices.1.06 For ceiling installations utilizing acousticaltile panels of mineral or glass fiber, it is notmandatory to provide ¾” clearance between theacoustical tile panels and the wall on the sides ofthe ceiling which are free to slip. For all otherceiling panel types, provide ¾” clearancebetween the ceiling panel and the wall on thesides of the ceiling free to slip.·MATERIALS:2.01 Ceiling wire shall be Class 1 zinccoated (galvanized) carbon steel conforming toASTM A641-09a. Wire shallbe #12 gage (0.106” diameter) with soft temperand minimum tensile strength = 70 ksi.2.02 Galvanized sheet steel (including that usedfor metal stud and track compressionstruts/post) shall conform to ASTM A653-11, orother equivalent sheet steel listed in Section A2.1of the North American Specification for theDesign of Cold-Formed Steel Structural Members2012, including supplement dated 2014 (AISIS100-12). Material 43 mil (18 gage) and lightershall have minimum yield strength of 33 ksi.Material 54 mil (16 gage) and heavier shall havea minimum yield strength of 50 ksi.2.03 Electrical metallic tube (EMT) shall be ANSIC80.3/UL 797 carbon steel with G90 galvanizing.EMT shall have minimum yield strength (Fy) of30 ksi and minimum ultimate strength (Fu) of 48ksi.·ATTACHMENT OF HANGER ANDBRACING WIRES:3.01 Separate all ceiling hanger and bracingwires at least six (6) inches from all unbracedducts, pipes, conduit, etc.3.02 Hanger and bracing wires shall not attach toor bend around obstructions including but notlimited to: piping, ductwork, conduit andequipment.3.03 Hanger wires that are more than one(horizontal) in six (vertical) out of plumb shallhave counter-sloping wires.3.04 Slack safety wires shall be consideredhanger wires for installation and testingrequirements.3.05 Hanger and bracing wire anchorage to thestructure shall be installed in such a manner thatthe direction of the anchorage aligns closely withthe direction of the wire. (e.g. bracing wireceiling clips must be bent as shown in the detailsand rotated as required to align closely with thedirection of the wire, screw eyes in wood must beinstalled so they align closely with the directionof the wire, etc.)·FASTENERS AND WELDING:4.01 Sheet metal screws shall comply with ASTMC1513-10, ASME B18.6.4-98 (R2005).Penetration of screws through joined materialshall not be less than three exposed threads.4.02 Expansion anchors shall be: [Notapplicable to project]4.03 Power-Actuated Fasteners shall be: [Notapplicable to project]4.04 If not otherwise specified in the evaluationreport, power-actuated fasteners installed insteel shall be installed so the entire pointed endof the fastener is driven through the steelmember.4.05 Power-actuated fasteners in concrete arenot permitted for bracing wires.4.06 Concrete reinforcement and prestressingtendons shall be located by non-destructivemeans prior to installing post - installed anchor.4.07 Welding shall be in accordance with AWSD1.3 using E60XX series electrodes.·TESTING: All field testing must beperformed in the presence of the projectinspector.5.01 Post-installed anchors in concrete used tosupport hanger wires shall be tested at afrequency of 10 percent. Power actuatedfasteners in concrete shall be field tested for 200lbs. in tension. All other post-installed anchors inconcrete shall be tested in accordance with CBCSection 1910A.5.5.02 Post-installed anchors in concrete used toattach bracing wires shall be tested at afrequency of 50 percent in accordance with CBCSection 1910A.5.·LIGHT FIXTURES:6.01 All light fixtures shall be positively attachedto the ceiling suspension systems by mechanicalmeans to resist a horizontal force equal to theweight of the fixture. A minimum of two screwsor approved fasteners are required at each lightfixture, per ASTM E580, Section 5.3.1.6.02 Surface-mounted light fixtures shall beattached to the main runner with at least twopositive clamping devices. The clamping deviceshall completely surround the supporting ceilingrunner and be made of steel with a minimumthickness of #14 gage. Rotational spring catchesdo not comply. A #12 gage slack safety wireshall be connected from each clamping device tothe structure above. Provide additional supportswhen light fixtures are eight (8) feet or longer orexceed 56 lb. Maximum spacing betweensupports shall not exceed eight (8) feet.6.03 Not used.6.04 Light fixtures weighing less than or equal to10 lb. shall have a minimum of one (1) #12 gageslack safety wire connected from the fixturehousing to the structure above.6.05 Light fixtures weighing greater than 10 lb.but less than or equal to 56 lbs. may besupported directly on the ceiling runners, butthey shall have a minimum of two (2) #12 gageslack safety wires connected from the fixturehousing at diagonal corners to the structureabove.Exception: All light fixtures greater thantwo by four feet weighing less than 56 lbs.shall have a #12 gage slack safety wire at eachcorner.6.06 All Light fixtures weighing greater than 56lb. shall be independently supported by not lessthan four (4) taut #12 gage hanger wires (one ateach corner) attached from the fixture housing tothe structure above or other approved hangers.The four (4) taut #12 gage wires or otherapproved hangers, including their attachment tothe structure above, shall be capable ofsupporting four (4) times the weight of thefixture.·SERVICES WITHIN THE CEILING:7.01 All flexible sprinkler hose fitting mountingbrackets, ceiling-mounted air terminals or otherservices shall be positively attached to the ceilingsuspension systems by mechanical means.Screws or approved fasteners are required. Aminimum of two attachments are required ateach component.7.02 Ceiling-mounted air terminals or otherservices weighing less than or equal to 20 lb.shall have one (1) #12 gage slack safety wireattached from the terminal or service to thestructure above.7.03 Flexible sprinkler hose fittings,ceiling-mounted air terminals or other servicesweighing more than 20 lb. but less than or equalto 56 lb. shall have two (2) #12 gage slacksafety wires (at diagonal corners) connectedfrom the terminal or service to the structureabove.7.04 Flexible sprinkler hose fittings,ceiling-mounted air terminals or other servicesweighing more than 56 lb. shall be supporteddirectly from the structure above by not less thanfour (4) taut #12 gage hanger wires attachedfrom the terminal or service to the structureabove or other approved hangers.·OTHER DEVICES WITHIN THECEILING:8.01 All lightweight miscellaneous devices, suchas strobe lights, occupancy sensors, speakers,exit signs, etc., shall be attached to the ceilinggrid. In addition, devices weighing more than 10lbs. shall have a #12 gage slack safety wireanchored to the structure above. Devicesweighing more than 20 lb. shall be supportedindependently from the structure above.NOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USEDNOT USED