Laserfiche WebLink
SCALE : 1/8" = 1'-0"FLOOR PLAN - LIGHTING1E2.133JJJJ(N) PANEL "KP1"EMEMEMKP1-1A52TYPICALB22TYPICAL156(N) PANEL "KP"KCL-GWSH: ("X48" "Y21" "Z63" "Q4" "FW" "P4" "LF" "V2D")X=48.0000 - Y=21.0000 - Z=63.0000KCL-GWSH: ("X48" "Y21" "Z63" "Q4" "FW" "P4" "LF" "V2D")X=48.0000 - Y=21.0000 - Z=63.0000KCL-GWSH: ("X54" "Y21" "Z54" "Q4" "FW" "P4" "LF" "V2D")X=54.0000 - Y=21.0000 - Z=54.0000KCL-GWSH: ("X54" "Y21" "Z54" "Q4" "FW" "P4" "LF" "V2D")X=54.0000 - Y=21.0000 - Z=54.0000KCL-GWSH: ("X48" "Y21" "Z63" "Q4" "FW" "P4" "LF" "V2D")X=48.0000 - Y=21.0000 - Z=63.0000SCALE : 1/8" = 1'-0"FLOOR PLAN - POWER2E2.1(N) PANEL "KP1"(N) PANEL "KP"SHPIA1CEFA1KEFA1SHPIA2SHPIA3SHPOA1SHPOA2SHPOA313/4"C., 3 #10, AND 1 #10G1"C.,3 #6, AND1 #10GKP1-10,12KP1-14,16KP1-18,20233KP1-13444777WPGFIKP1-1538JJGWHA1CPA1JKP1-17HTCA1KP1-19JKP-229IOAFA1CEFA210IOAFA21111KP1-22KP1-22JKP1-2112WPWPWPACA21-1/4" C., 3 #4,AND 1 #8 GND.KP1-26,28,303/4"C., 3 #10, AND 1 #10GJKP1-2313NUMBERED NOTES:1CONNECT EXHAUST FAN INTO LIGHTING CKT. SUCH THAT FAN SWITCHES WITH LIGHT IN R.R.CONNECT VIA EXHAUST HOOD (FANS CONTROLLER SUPPLY) EH3; REFER TO 1/E2.3 ANDFOOD SERVICE PLANS.INDOOR SPLIT SYSTEM UNIT POWERED FROM ASSOCIATED OUTDOOR SPLIT SYSTEM UNIT.PROVIDE CONDUIT, CONDUCTORS, AND CONNECT PER MANUFACTURER REQUIREMENTS.PROVIDE FOR AND CONNECT CONDENSATE PUMP AND CENTRIFUGAL DUCT FAN.COORDINATE WITH MECHANICAL BEFORE ROUGH IN.PROVIDE LINE VOLTAGE DIMMER / ON-OFF SWITCH WITH OCCUPANCY SENSOR.PROVIDE LINE VOLTAGE ON-OFF SWITCH WITH OCCUPANCY SENSOR.MOUNTED ON ROOF. REFER TO MECHANICAL PLANS.ROOF MOUNTED FOR MAINTENANCE. PROVIDE IN WP ENCLOSURE WITH WHILE-IN-USECOVER.PROVIDE FOR AND CONNECT AUTOMATIC GAS SHUTDOWN. RUN THROUGH FIRE ALARMRELAY MODULE, REFER TO 2/E3.0. COORDINATE WITH PLUMBING CONTRACTOR BEFOREROUGH IN.CONNECT FAN INTO (E) LIGHTING CKT. SUCH THAT FAN SWITCHES WITH LIGHT.PROVIDE CONDUIT/CONDUCTORS FROM FAN TO ASSOCIATED SPLIT SYSTEM. COORDINATEWITH MECHANICAL BEFORE ROUGH IN.PROVIDE FOR AND CONNECT OVERHEAD MOTORIZED ROLL UP DOOR. INSTALL SWITCHPROVIDED WITH THE DOOR, COORDINATE EXACT LOCATION WITH THE ARCHITECT PRIOR TOROUGH IN. DOOR SHALL BE CONNECTED SUCH THAT IT ROLLS DOWN IN CASE OF FIREALARM. REFER TO MANUFACTURER INSTRUCTIONS AND FIRE ALARM PLAN FOR ADDITIONALREQUIREMENTS.PROVIDE FOR AND CONNECT FIRE/SMOKE DAMPER. REFER TO 3/E4.0 DIAGRAM FORCONNECTION.2345678910111213UNSWITCHED POWER FROMPANEL KP1, CKT. #1ON/OFF, DIMMINGCONTROLLERON/OFF, DIMMING, LOWVOLTAGE SWITCHOCCUPANCY SENSOR, SYMBOL REPRESENT SPACETO BE CONTROLLED, NOT EXACT LOCATION ANDNUMBER OF THE SENSORS. CONTRACTOR SHALLSUBMIT FLOOR PLAN WITH EXACT LOCATIONS ANDQUANTITIES FOR APPROVAL.LOW VOLTAGEWIRING3ON/OFF 3-wayJN.T.S.LIGHTING SWITCHING DIAGRAMS3E2.1PROVIDE UNSWITCHED "HOT" TO "EM" FIXTURES0-10 V WIRING TO LIGHT FIXTURE DRIVERUNSWITCHED POWER TO OTHERLIGHT FIXTURES__FLOOR PLANS - LIGHTING <br />AND POWERE2.1Electrical Engineers Lighting Designers100 Howe Ave., Suite 235NSacramento, CA 95825-8217Tel: (916) 923-4400 Fax: (916) 923-4410www.mneilsengineering.comPROJECT #: 19276.2104/09/2020SHEETSOF730 Howe Avenue, Suite 450 <br />Sacramento, CA 95825 <br />Phone: 916.921.2112 <br />Fax: 916.921.221268KITCHEN RENOVATION <br />HOUSTON (SERNA) SCHOOLSHEET NO.CONSULTANTUPDATEDCADFILECHECKEDDRAWNSCALEPROJECT NO. DATE04/10/2020REVISIONSBY19-32-050SLHSLHFILE NO. 39-50 APP NO. 02-118041