__FIRE ALARM DETAILS, <br />DIAGRAMS, MATRIXE4.0Electrical Engineers Lighting Designers100 Howe Ave., Suite 235NSacramento, CA 95825-8217Tel: (916) 923-4400 Fax: (916) 923-4410www.mneilsengineering.comPROJECT #: 19276.2104/09/2020SHEETSOF730 Howe Avenue, Suite 450 <br />Sacramento, CA 95825 <br />Phone: 916.921.2112 <br />Fax: 916.921.221268KITCHEN RENOVATION <br />HOUSTON (SERNA) SCHOOLSHEET NO.CONSULTANTUPDATEDCADFILECHECKEDDRAWNSCALEPROJECT NO. DATE04/10/2020REVISIONSBY19-32-050SLHSLHFILE NO. 39-50 APP NO. 02-118041EST3XFIRE ALARM EQUIPMENT SCHEDULESYMBOLCATALOG NO.DESCRIPTIONLISTING No.CSFMFACPEST E-RLED-CANN(E) REMOTE ANNUNCIATORSPEAKER/STROBE, WALL MOUNTEDWHEELOCK LSPSTR7125-0785:0175MONITOR MODULEEST SIGA-MM17300-1657:0121MM7270-1657:0109HEAT DETECTOR - FIXED TEMP 194°AND RATE-OF RISEEDWARDS SIGNALING 282B-PLSTROBE, WALL MOUNTEDWHEELOCK LST7125-0785:0169(E) FIRE ALARM CONTROL PANEL W/VOICE EVACUATION CAPABILITIESFIRE LITE FCPS-24FS6FAPS(E) FIRE ALARM POWER SUPPLY7270-1657:0125HEAT DETECTOR - FIXED TEMP 135°AND RATE-OF RISEEST-HRSSLC TO FROM24 VDCDIAGRAM IS GENERIC THEREFORE CONTRACTOR SHALL COORDINATE WORK FOR SPECIFIC DEVICES USED.REFER TO MANUFACTURER INFORMATION FOR TYPE OF CABLE, MAX. LENGTH, T-TAPING, GROUNDING, ETC.DRAIN WIRE TO BE CAPPED ANDTAPED AT EACH DEVICE(WHERE SHIELDED CABLE IS USED).GROUND SHIELD AT FACP ONLY.FACPNOTE:SHLDDEVICENEXTMONITOR MODULEADDRESSABLE INITIATION DEVICENON-ADDRESSIBLEINITIATIONDEVICETO NEXT HEAT DET. OREND-OF-LINE RESISTOR24 VDCSTROBESPEAKEREVAC, FROM25 VrmsTO NEXTOR EOLDEVICERESISTORNACFROMAMP.SHLDTO NEXT DEVICEOR EOL RESISTORTAPE OFF AT LAST SPEAKERN.T.S.FIRE ALARM DEVICES DIAGRAM1E4.0TYPICAL INITIATION AND NOTIFICATION A/C SUPPLY DIFFUSER4"MIN24" MIN HANDICAPBEDROOM STROBE5' MAX3'MINSTROBE15' MAX WITHINEND OF CORRIDOR100'MAX SPACINGNEVERHEREWALL MOUNTEDSMOKE/HEATDETECTORCEILING MOUNTEDSMOKE/HEATDETECTORFINISHEDWALLAUDIBLE ONLY DEVICES:MOUNT AT 90" MINIMUM,AND NOT LESS THAN 6"BELOW CEILINGCEILINGNO SCALEAPPLIANCE ELEVATION DETAIL2E4.04"12"MAXAUDIBLE/VISIBLE ONLY DEVICES:MOUNT AT 80" MINIMUM, TO TOP OF LENS96" MAXIMUM TO BOTTOM OF LENS.PULL STATIONMOUNT AT 48" MAX.TO TOP OF LEVER OROPERABLE PARTFLOOR96"MAX.80"MIN.90"NOTE: BLANK MEANS NOT APPLICABLELOSS OF CARRIEROPEN WIREOPEN & GROUNDWIRE TO WIRE (SHORT & OPEN) GROUNDED WIREGROUNDED WIRESHORTED WIRESSIGNALING LINE CIRCUITCLASS BOPEN WIRENOTIFICATION CIRCUIT CLASS BPOWER FAILURER = REQUIRED ACTIONXXXXXXXXXXXXXXXXXXRRFIRE ALARM SEQUENCE OF OPERATION MATRIXXXWIRE TO WIRE (SHORT & GROUND) ACTIVATE AUDIO/VISUAL <br />THROUGHOUT <br />ANNUNCIATE ALARM AT REMOTE <br />ANNUNCIATORAREA SMOKE DETECTORXXXXXFACP ALARM <br />FACP TROUBLE <br />ALARM SIGNAL OFF-SITE <br />TROUBLE SIGNAL OFF-SITE <br />ALARM RECEIPT CAPABILITY <br />DURING ABNORMAL CONDITIONSX <br />1.REVISE EXISTING FIRE ALARM IN MODERNIZED PORTION OF THE BUILDING.2.(E) FIRE ALARM CONTROL PANEL IS CAPABLE OF AUTOMATICALLY TESTING SMOKE DETECTORS ANDPRINTING A REPORT OF THE TEST.3.(E) FIRE ALARM CONTROL PANEL INCLUDES AUTOMATIC DIALING CAPABILITY FOR SENDING ASUPERVISORY SIGNAL, A TROUBLE SIGNAL, AND AN ALARM SIGNAL TO AN APPROVED SUPERVISINGOFF-SITE MONITORING STATION IN ACCORDANCE WITH NFPA 72. THE SUPERVISING STATIONSSHALL BE LISTED AS EITHER UUFX (CENTRAL STATION) OR UUJS (REMOTE AND PROPRIETARY) BYUL, OR SHALL COMPLY WITH THE REQUIREMENTS OF STANDARD FM 3011. DIALER SHALL BECAPABLE OF "GRABBING" A PHONE LINE FOR AN ALARM SIGNAL IF PHONE LINE IS ALREADY IN USE.4.UPON COMPLETION OF FIRE ALARM SYSTEM REVISION, A SATISFACTORY TEST OF THE ENTIRESYSTEM SHALL BE MADE WITH THE LOCAL FIRE MARSHALL AND THE PROJECT INSPECTOR OFRECORD AS WITNESSES.5.THE FIRE ALARM SYSTEM SHALL CONFORM TO THE CALIFORNIA BUILDING CODE, CALIFORNIAELECTRICAL CODE, ARTICLE 760, AND THE CALIFORNIA FIRE CODE.6.REVISION TO THE FIRE ALARM SYSTEM SHALL HAVE AUTOMATIC INITIATION DEVICES, AND FULLCOVERAGE.7.PROVIDE "FIRE WATCH" DURING CONSTRUCTION WHEN EXISTING FIRE ALARM SYSTEM IF TURNEDOFF, OR OFF LINE.8.THE FIRE ALARM WIRING SHALL BE RUN IN CONDUITS.9.DO NOT START INSTALLATION OF THE FIRE ALARM SYSTEM UNTIL DETAILED PLANS,SPECIFICATIONS AND CALIFORNIA STATE FIRE MARSHAL LISTING NUMBERS FOR EACH COMPONENTOF THE SYSTEM HAVE BEEN APPROVED BY THE DEPARTMENT OF STATE ARCHITECTS.10.PER NFPA 72 2016, SECTIONS 10.6.5.2.2 AND 10.6.5.2.3, CIRCUITS FOR FIRE ALARM SYSTEMS SHALLBE IDENTIFIED AS "FIRE ALARM / ECS CIRCUIT", AND THE DISCONNECTING MEANS FOR THE CIRCUITSHALL HAVE A RED MARKING, BE ACCESSIBLE ONLY TO AUTHORIZED PERSONNEL AND SHALL BEMECHANICALLY PROTECTED. LOCATION OF THE DISCONNECT SHALL BE PERMANENTLY IDENTIFIEDAT THE FIRE ALARM CONTROL UNIT. THE CIRCUITS FOR FIRE ALARM SYSTEMS SHALL BEDEDICATED TO FIRE ALARM EQUIPMENT.11.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE ON THE JOB SITE AND USED FORINSTALLATION. ANY DEVIATION FROM THE APPROVED PLANS, INCLUDING THE SUBSTITUTION OFDEVICES, SHALL BE APPROVED BY THE DEPARTMENT OF STATE ARCHITECTS.12.13. A FIRE ALARM ACCEPTANCE TEST OF ALL DEVICES AND APPLIANCES, INCLUDING THE BACKUPBATTERY(IES), SHALL BE PERFORMED. ALL MANUFACTURER OPERATING RANGES SHALL BE MET.TESTING OF THE SUPERVISING STATION SIGNALS, AS WELL AS RELAY TO THE APPROPRIATERESPONDING AGENCY, SHALL BE INCLUDED IN THE ACCEPTANCE TESTING. THE PROJECTINSPECTOR SHALL WITNESS THE ACCEPTANCE INSPECTION AND SHALL SIGN AS THE AHJREPRESENTATIVE ON THE "SYSTEM RECORD OF COMPLETION" AT SECTION 12.3 (NFAP 72, FIGURE7.8.2(a)). ALL SUPPLEMENTARY RECORDS SHALL BE ATTACHED AS APPLICABLE. THE PROJECTINSPECTOR SHALL VERIFY THAT THE FIRE ALARM SYSTEM IS IN SERVICE PRIOR TO COMPLETION OFTHE "SYSTEM RECORD OF COMPLETION" FORM. ALL ORIGINAL DECANTATION SHALL BE RETAINEDIN THE REQUIRED DOCUMENTATION CABINET (NFPA 72, 7,7,2).13.A CERTIFICATE OF COMPLIANCE SHALL BE PREPARED BY THE INSTALLER AND GIVEN TO THECALIFORNIA STATE FIRE MARSHAL UPON COMPLETION OF THE INSTALLATION.FIRE ALARM GENERAL NOTESSMOKE PHOTOELECTRIC DETECTOREST SIGA-PS7272-1657:0126HEAT DETECTORSXXXXKITCHEN HOOD FIRESUPPRESSION SYSTEMXXXXSHUT OFF POWER TO DEVICES <br />UNDER KITCHEN HOODX <br />SEND SIGNAL TO MECHANICAL <br />CONTROLS TO INITIATE REQUIRED <br />ACTIONS BY MECHANICAL CONTROLSXSHUT OFF GAS SUPPLY TO <br />KITCHENXNO SCALE(E) FIRE / SMOKE DAMPER DIAGRAM3E4.0RMFA INITIATION CKT.FIRE / SMOKE DAMPERREFER TO MECHANICALPLANS120V CKT. FOR CLOSINGDAMPER UPON FA CONDITION.CONNECT THROUGH RELAY IN(N) FA RELAY MODULE, REFERTO FLOOR PLAN POWER.FA RELAY MODULEDUCT DETECTORXXXXXRELAY MODULEEST SIGA-CR7300-1657:0121RM3242-1657:0223DUCT DETECTOREDWARDS SIGA-SD