Laserfiche WebLink
TO TOP OF CABINET OR SINKWHICHEVER IS HIGHERNOTES:1.PROVIDE SIDES AND BACK.DELETE FRONT DOORS.2.EXTEND FLOORING ANDBASE INTO CABINET.3.INSULATE WATER SUPPLYPIPES AND DRAIN PIPESUNDER ACCESSIBLEFIXTURES TYP.4.SEE DETAILS ON SHEET A0.1FOR ACCESSIBLE SINKCLEARANCE REQUIREMENTS.4" @ 2'-0" DEEP & DEEPER #10x2" F.H.W.S. @ 12" O.C. 2" @ 1'-0" DEEP CASEWORKCASEWORK DOOR OR DRAWERRUBBER BASEFINISH FLOOR2x4 PPT WOOD NAILER - FULL WIDTH OFCASEWORK FRONT6d FIN. NAILS @ 6"O.C.CASEWORKCASEWORK UNIT1"x3" WOOD NAILER, TYP.FINISHED FACE OF WALLSCRIBE BACKSPLASH TO WALLWOOD SHIM TYP.BACKSPLASH & COUNTERTOP ASOCCURS, SEE INTERIOR ELEVATIONS-TOP OF CABINET ORSUB-TOP WHERE OCCURSCAULK SPLASH TO WALL4 X BLOCKING PER DETAIL 8/A0.1HILTI X-CP PDF (0.145" Ø x 2 78") @ 24" O.C.(1 38" MIN. EMBED) WITH 78" Ø WASHERWOOD/MTL STUD WALLS: #14 P.H.W.S. @ 6"FROM EACH END AND 12" O.C. (3 MIN. PERCABINET AT BASE CABINETS) (USE 1-1/2" X 18"CONT. ANGLE AND 4 MIN. AT TALL CABINETS)WITH 1-1/2" MIN. PENTRATION INTO 4XBLOCKING.07DOOR SCHEDULE <br />FINISH SCHEDULEA3.1SHEETSOF730 Howe Avenue, Suite 450 <br />Sacramento, CA 95825 <br />Phone: 916.921.2112 <br />Fax: 916.921.221271KITCHEN RENOVATION <br />HOUSTON (SERNA) SCHOOLSHEET NO.CONSULTANTUPDATEDCADFILECHECKEDDRAWNSCALEPROJECT NO. DATE04/10/2020REVISIONSBY19-32-050SLHSLHFILE NO. 39-50 APP NO. 02-118041WOODWDMATERIAL <br />FINISH FRAMEMARK/TYPEDOOR DOOR SCHEDULEWIDTH X HEIGHTCONSTRUCTIONFINISHGLAZINGHARDWARE <br />DETAILSDOOR SIZEGROUP <br />HEADJAMBSILLDOOR LEGENDTEMPERED SAFETYPAINTSTAINSTPHOLLOW METALHMFIBER GLASSFGDOOR TYPE <br />SOLID CORE WOODSCPREFINISHED METALPMA101DOOR NOTES1.EXTERIOR DOORS SHALL BE WEATHERSTRIPPED AND ALL JOINTS ANDPENETRATIONS SHALL BE CHALKED ANDSEALED.2.PROVIDE TACTILE EXIT SIGN PER DETAIL3/A0.13.PROVIDE ROOM IDENTIFICATION SIGN PERDETAIL 2/A0.1.4.PROVIDE TOILET ROOM IDENTIFICATION SIGNPER DETAIL 2/A0.15.PROVIDE TOILET ROOM DOOR SYMBOLS PERDETAIL 2/A0.1.6.ALL DOORS INTERIOR AND EXTERIOR SHALLHAVE 12" MAXIMUM HIGH THRESHOLD (ABOVEFLOOR AND LANDING ON BOTH SIDES &WHERE REQUIRED BY HARDWARE GROUP),WITH MAXIMUM DOOR OPENING EFFORT OF 5LBS. AT EXTERIOR AND AT INTERIOR DOORSAND ARE EQUIPPED WITH SINGLE-EFFORT,NON-GRASPING TYPE HARDWARE (I.E.LEVER)CENTERED BETWEEN 34" & 44" ABOVE FLOOR.2016 CBC, SECTIONS 11B-404.2.5, 11B-404.2.7,11B-404.2.9.7.REQUIRED EXIT DOORS TO BE EQUIPPEDWITH PANIC HARDWARE8.PROVIDE 1'-6" WIDE X 1'-0" HIGH LOUVER9.ALL EXTERIOR DOOR GLAZING SHALL BEDOUBLE PANE INSULATING GLASS.10.FLOOR DOOR STOPS TO BE LOCATED SO ASNOT TO CAUSE A TRIPPING HAZARD AND 4"MAX. FOR WALL.11.UNDERCUT DOOR FOR 12" MIN. CLEARANCE.12.UNDERCUT DOOR 1" FOR VENTILATION13.DOOR EQUIPPED WITH ELECTRONIC ACCESSCONTROL SYSTEM14.PROVIDE POWER FOR ELECTRIC MOTOROPERATION. VERIFY SWITCH LOCATION.15.SEE ORNAMENTAL METAL FENCE DETAILS.16.RATED OVERHEAD COILING COUNTER DOORTO BE EQUIPPED W/ AUTOMATIC CLOSUREACTIVATED BY CENTRAL FIRE ALARM SYSTEM.SEE SPECIFICATION SECTION 08 33 13 FORADDITIONAL REQUIREMENTS.BUILDING AFIRE RATING <br />FACTORY FINISHFEXISTINGE3'-0" X 7'-0"ADOOR NOTESALUMINUMALTEMPERED CLEART.CLRSTAINLESS STEELSSHMP--HMP1, 2, 3, 6DOOR TYPES4/A8.25/A8.26/A8.2NOTESMATERIAL/FINISH LEGEND1.USE WATER RESISTANT GYPSUM BOARD AT KITCHEN, BATHROOMS AND WET AREAS -TYPICAL.2.INTEGRAL COVE BASE MUST HAVE 38" MINIMUM RADIUS COVING AND SHALL EXTEND ATLEAST 6" UP WALL.3.PROVIDE R-19 BATT INSULATION AT EXTERIOR WOOD STUD WALLS; PROVIDE R-38 BATTINSULATION AT ROOF JOISTS4.EXTERIOR WALL INSULATION SHALL EXTEND TO THE ROOF STRUCTURE AND SHALLCREATE AN ENVELOPE WITH THE ROOF INSULATION.5.BATT INSULATION INSTALLED AT THE ROOF SHALL BE INSTALLED BETWEEN JOISTS.WHERE BATT ROOF INSULATION IS EXPOSED TO OCCUPIED SPACE BELOW, THEINSULATION SHALL BE PAPER FACE AND INSTALLED NEATLY, READY FOR PAINT.6.PROVIDE SOUND INSULATION AT INTERIOR WALLS AND CEILING.7.PATCH AND REPAIR WALLS & CEILING (12x12 ACOUSTICAL TILE OVER GYPSUM BOARD ATCEILING AND GYPSUM BOARD AT WALLS) PRIOR TO PAINTING8.ALL FLOOR FINISH MATERIALS SHALL CONFORM TO CBC SECTION B04 FOR MINIMUMCRITICAL RADIANT FLUX AND OPTICAL DENSITY SMOKE RATING.9.A WALL AND CEILING FINISHES SHALL CONFORM TO CBC SECTION B04 FOR FIREPERFORMANCE AND SMOKE DEVELOPMENT.10.PATCH AND REPAIR (E) WALLS PRIOR TO PAINTING.MATERIAL & FINISH SCHEDULEROOM <br />NUMBER <br />ROOM NAMEMATERIAL <br />FINISH <br />FINISH <br />MATERIAL <br />HEIGHT <br />MATERIAL <br />FINISH <br />MATERIAL NMATERIAL <br />FINISH EFINISH <br />MATERIAL SFINISH <br />MATERIAL WFLOORBASEWAINSCOTWALLSNOTESCEILINGFINISH <br />MATERIAL <br />HEIGHT A1023'-0" X 7'-0"AHMP--HMP3, 62/A8.22/A8.26/A8.2A1033'-0" X 7'-0"AHMP-HMP3, 62/A8.26/A8.2A1043'-0" X 7'-0"AHMP--HMP4, 52/A8.26/A8.2A1054'-0" X 4'-0"BSS--90-Min.SS-14, 167/A8.28/A8.29/A8.22/A8.22/A8.2A101KITCHENRE-6B-FRP19'-0"G1G1PG1PG1P1, 2, 3, 4, 5, 69'-0"A3FA102FOOD LOCKERRE6BFRP19'-0"G1PG1PG1PG1PVARIESG1PA103TEACHER ROOMRT4B--PEPPP9'-0"EPA104STAFF TOILETRE6BFRP19'-0"G1-G1---9'-0"G1PA105JAN/STORRE6BFRP18'-0"E-E-9'-0"A106MP-4B------G1P-----------EG1E---EE-E-P-2, 3, 4, 5, 671, 2, 5, 61010ABLOUVER WHEREOCCURSLOUVER WHEREOCCURS010304020590-Min.10" Clr. Min.OVERHEAD COILINGCOUNTER DOORG14B 4" RUBBER BASE6B 6" INTEGRAL COVE BASE (RESINOUS)C1 CARPET TILEC2 WALK-OFF CARPET TILERT RESILIENT TILE FLOORINGRS RESILIENT SHEET VINYL FLOORINGRE RESINOUS FLOORINGG1 5/8" GYPSUM BOARDG2 5/8" TYPE "X" GYPSUM BOARDGE GYPSUM BOARD EXISTINGCON CONCRETECS CONCRETE SEALP PAINTN NO FINISHE EXISTINGF FACTORYFRP1FIBER REINFORCED PLASTIC PANELFRP2FIBER REINFORCED PLASTIC PANELVWTVINYL WRAPPED TACKBOARDA1 2' X 4' SUSPENDED ACOUSTICAL CEILINGSYSTEM TYPE A1A2 2' X 2' SUSPENDED ACOUSTICAL CEILINGSYSTEM TYPE A1A3 2' X 4' SUSPENDED ACOUSTICAL CEILINGSYSTEM TYPE A2CASEWORK SCHEDULECABINET NUMBER <br />WIDTH <br />HEIGHT <br />PLASTIC LAMINATE <br />DEPTH <br />COUNTERTOPSIZE (INCHES)FINISHNOTES154A154KEYW.I. NUMBER*CASEWORKFINISHPLASTIC LAMINATE363424222A222303424NOTES1.HEIGHT PROVIDED FOR BASE CABINETS IF FROM FINISHED FLOOR TO TOP OFCOUNTER TOP. ACTUAL HEIGHT OF BASE CABINET IS LESS.2.SEE DETAIL 1 THIS SHEET FOR ADA SINK BASE DETAIL.3.SEE DETAIL 2 THIS SHEET FOR CABINET ANCHORAGE.1ACCESSIBLE CASEWORKSCALE: 1/2"=1'-0"2CABINET ANCHORAGESCALE: 3"=1'-0"1, 2, 31, 3PE