7 1. LAVATORY OR SINK IDENTIFICATION STAMP <br /> 1 1 2. COUNTER 1 2 3 4 5 DIV. OF THE STATE ARCHITECT <br /> 1. HOT WATER RETURN 2 3. SLIP-JOINT FITTING APP. 02-117806 INC: 3 <br /> 16 4. TRAP <br /> 2. AQUASTAT MH N0. AQS-3/4 SET TO 5 5. WALL REVIEWED FOR <br /> START AT 125°F AND STOP AT 135°F. 2 <br /> r 8 6. FINISHED FLOOR SS p FLS 0 ACS <br /> LOCATE MIN. 10'-0" UP STREAM FROM 7. 3/4" CONDENSATE DRAIN ° <br /> WATER HEATER. 14 ° ° DATE: 03/03/2020 <br /> 3. CIRCULATING PUMP - SEE FIXTURE I IN WALL. _IIII _= <br /> 8. NEOPRENE HOSE & CLAMPS <br /> SCHEDULE. I 9. ESCUTCHEON PLATE IIII=III III=_IIII - <br /> 4. CHECK VALVE _ � I 3 <br /> 5. HOT WATER OUTLET - / I IIII=I =IIII 1 . FINISHED FLOOR OR <br /> 6. GATE VALVE (TYPICAL) � 3 I 9 SIDEWALK. <br /> 7. ASME TEMP. & PRESSURE RELIEF VALVE. I 2. PRE-CAST CONCRETE BOX <br /> 8. FULL SIZE RELIEF TO JAN SINK. WITH CAST IRON COVER. <br /> 9. COLD WATER INLET 6 4 I 4 Cr LABEL THE COVER <br /> 10. MAGNESIUM ANODE ` <br /> "WATER". <br /> 11. SECURE WATER HEATER W/ (2) 16 GA. x 7 _ 15 I 3. 18"08" CAST CONIC. <br /> 2" SHEET METAL STRAPS TO MINIMUM 4x <br /> BLOCKING IN WALL. ATTACH 4x BLOCKING 9 I 6 AROUND UNPAVED AREA. <br /> TO STUDS w SIMPSON A34 TOP & � I 5 4. 1I 2" SLOPE. w <br /> / I 5. FINISHED GRADE. ro <br /> BOTTOM EACH END. 3 - 8d NAILS PER 6 6. VIT CLAY OR PVC <br /> A34 LEG. LOCATE STRAPS ON TOP AND 1 p I EXTENSION SLEEVE. <br /> BOTTOM THIRD OF WATER HEATER. 8 I ` 7 7. UNION (TYP). o <br /> BOTTOM STRAP TO BE LOCATED OF 4" o N <br /> ABOVE CONTROLS. 3/8"x3" LAG BOLT FOR <br /> WOOD FRAMING, 2" EMBEDMENT. <br /> 12. DRAIN COCK 11 13 <br /> 13. 2"x2%3/16" WASHER EACH END. WH NTS NTS 0 <br /> 14. EXPANSION TANK, SEE SCHED. 1 o CONDENSATE TO TAILPIECE DETAIL rj CW SHUT-OFF VALVE W <br /> 15. HOSE BIBB FOR SYSTEM PRIMING. <br /> 16. MANUAL AIR VENT. r 1 v <br /> 17. 22 GA. GALVANIZED PAN WITH 2" LIP, <br /> 18. 3/4" DRAIN - ROUTE TO OUTSIDE, SEE <br /> PLAN 1. CAST IRON CLEANOUT <br /> 121. VENT STACK IN DOUBLE FLANGED ° <br /> � <br /> c 1 2. FACE OF WALL HOUSING WITH HEAVY <br /> NOTE: <br /> \ DUTY CAST IRON rL•i <br /> A. PIPE SIZES TO BE SHOWN ON PLANS & ? 3. SANITARY TEE COVER (TYP 2) O b <br /> EXTENDED FULL SIZE TO WH CONNECTIONO2 4. CHROME PLATED COVER & 2. CONCRETE SURFACE, 1 2 6 3 v a <br /> B. WH IS GROUND SUPPORTED AND PRESSED 17 18 SCREW MIN. 4" THICK V--1 <br /> TIGHT AGAINST WALL. 5. THREADED PLUG 3. FINISHED GRADE <br /> 6. NO-HUB COUPLING 4. NO-HUB COUPLING <br /> 3 ° <br /> STAINLESS STEEL COVER 5. MIN. 18"X18"X4" <br /> 7. DRAIN LINE THICK CONCRETE <br /> NTS 4 COLLAR (OMIT WHERE - - .' III =III= 1 <br /> ELECTRIC WATER HEATER DETAIL 10 SURFACE CONCRETE =III=III III= a-III= <br /> GQ " <br /> OCCURS) <br /> 5 6. CLEAN-OUT PLUG " <br /> (TYP 2) =1 111 1111 o <br /> 6 II 1 1I I- IIIIIII 1I I Q o a <br /> �IIIII�IIIII�III II�IIIII�IIIII_IIIII�III IIII� IIIFI b <br /> 1. FACE OF WALL 1 ^/ <br /> 2. 3/4" CW 2 04 <br /> 3. 1/2" GV 5 H <br /> 4. UNION 3 7 4 r <br /> 5. 1/2" CW DOWN <br /> 6. SEAL WATERTIGHT 12 NOTE: SEE SPECIFICATIONS <br /> 7. 1/2" CW BELOW CAST IRON PIPE FOR PIPE MATERIAL Z{ <br /> FLOOR � ^ � 0 <br /> 8. 1/2" CW TRAP, 4 H <br /> CONNECT AS <br /> REQ'D. 1 z <br /> 9. FINISH FLOOR <br /> 10. FLOOR DRAIN NTS PPIC003A NTS r■1••1 ° <br /> 11. ACCESS PANEL <br /> (STAINLESS STEEL) WALL CLEANOUT 6 TWO-WAY CLEANOUT (COTG) 2 <br /> 12. TRAP PRIMER 9 1 p 6 r--I <br /> " <br /> � ro <br /> �y •;'�°•~° iJ•.i:.• •�• •ter. ••� �~° •r�•�•• •j <br /> 1. MECHANICAL ° <br /> EQUIPMENT2. <br /> b <br /> 7 1 1. ROUND ADJUSTABLE CAST 1 3. TRAPNVENT, DO NOT <br /> 8 IRON TOP, TRACTOR 5 CAP CLOSED <br /> COVER. SET TOP FLUSH 2 4. SLOPE CONDENSATE <br /> WITH CONCRETE. DRAIN AT 1/8" PER <br /> 2 2. TOP OF CONCRETE FLOOR. FOOT, MIN. SEE PLAN <br /> 3. CAULK JOINT WITH LEAD, FOR SIZE AND ROUTING <br /> NO WATER TO STAND ON 5. CLEAN-OUT PLUG <br /> PPIEQ42ALIP. <br /> NITS PRIMER PIPING DETAIL _ 4. S.S. RETAINING CLAMP. <br /> IIII-IIII-_=_ ° =_IIII-IIII 5. C.I. 1/8 BEND. 3 <br /> IIII-IIII-IIII- IIII-IIII 6. C.I. DRAIN LINE. <br /> 4" MIN. <br /> ° <br /> 4 <br /> 3 <br /> 1. PIPING, SEE PLAN FOR SIZE AND ROUTING 4 <br /> 2. PIPE INSULATION WHERE REQUIRED <br /> 3. INSULATION PROTECTION SHIELD FOR INSULATED PIPING 5 o <br /> 4. STANDARD CLEVIS HANGER UNLESS OTHERWISE NOTED IN SPECIFICATIONS <br /> 5. MASON INDUSTRIES SEISMIC SOLID BRACE SWIVEL ANCHOR 2-3/4" MIN. <br /> 6. B-LINE B22 CHANNEL, SECURE TO SEISMIC BRACE ANCHOR WITH NUTS, WASHERS AND 6 <br /> CHANNEL NUTS <br /> 7. 3/8"0 THREADED ROD WITH MIN. (3) SEISMIC ROD CLAMPS, PROVIDE ADDITIONAL ROD <br /> CLAMPS PER MFR RECOMMENDATIONS NOTE: SEE SPECIFICATIONS <br /> 8. 3/8"0 NUT AND WASHER, TOP AND BOTTOM. TYP. CAST IRON PIPE FOR PIPE MATERIAL <br /> 9. B-LINE 83224-3/8 HANGER ADJUSTER, ATTACH TO ANGLE CLIP WITH 3/8"0 NUTS AND MEEHLEIS <br /> WASHER MODULAR <br /> 10. 2"x2'x1/4" ANGLE CLIP, SECURE TO CHANNEL WITH NUT, WASHER AND CHANNEL NUT BUILDINGS INC. <br /> 11. B-LINE B22 CHANNEL, ATTACH TO MIN. (2) ZEE PURLINS WITH 3/8"0 NUTS AND WASHER <br /> 12. PURLIN, SEE METAL BUILDING DRAWINGS PURLINS TO BE 14 GA. C SHAPED CHANNELS TYP. A DESIGN BUILD <br /> FLOOR CLEANOUT NITS7 CONDENSATE DRAIN CONNECTION NITSCOMPANY <br /> 1303 E. LODI AVE. <br /> 12 LODI, CA. 95240 <br /> (209) 334-4637 <br /> 1. STORM DRAIN PIPING UP TO CA. LIC. NO. 473488 <br /> Coordinate structural. ROOF DRAIN. NV. LIC. NO. 37887 <br /> shape with sttruct1 p 2. FACE OF EXTERIOR WALL <br /> C-shaped? 3. SANITARY TEE <br /> 1 <br /> ° 4. KARP MODEL DSC-214M <br /> 11 7 FLUSH 12"X12" ACCESS <br /> 9 2 <br /> ��� -O DOOR. PAINT, COLOR BY <br /> 8 1. WATER INLET. ARCHITECT. <br /> TEL AMO+NT BO -OMOF - - - <br /> g 3 <br /> 2. RECESSED WALL BOX. 5. THREADED PLUG 0- <br /> 3. BALL VALVE. 6. NO-HUB COUPLING <br /> 4. WATER HAMMER STAINLESS STEEL COVER 4 <br /> 4 ARREST. PDI-A 7. STORM DRAIN LINE TO <br /> OUTSIDE. <br /> i 5 <br /> 6 o II <br /> 1 4 <br /> 5 „ 6 <br /> 2 <br /> SEISMIC BRACING PLAN 3 7 <br /> 1 1± <br /> DRAWN: AT <br /> PRISM 0C TYP SEISMIC PIPE SUPPORT NITS12 WATER SUPPLY BOX NITSw PPIC004A STORM DRAIN WALL CLEANOUT NITS4 CHECKED: JD <br /> vj REVISIONS: <br /> 01/03/20 DSA CORRECTIONS <br /> 1. PIPING ON ROOF. NOTE: <br /> 2. PVC SINGLE PLY PROTECTION 1. PROVIDE PIPE SUPPORT AT MAXIMUM SPACING OF 8FT. <br /> MATERIAL. <br /> 3. ROOFING MATERIAL. 6 1 <br /> 4. 'B-LINE' 'DURA-BLOK' ROOTOP <br /> PIPE SUPPORT OR EQUAL. WOOD 1 . FINISHED GRADE <br /> BLOCKING NOT ACCEPTABLE. 1 2 3 2. CAST CONCRETE <br /> 5. 'B-LINE' 14 GA. GALVANIZED AROUND UNPAVED <br /> SLOTTED 1" CHANNEL. AREA. <br /> WITH THRU-BOLT. <br /> 6. LINE' SERIES PIPE CLASP 3/4 3. SOLID CAST IRON LID DATE MAY 1312019 <br /> WITH <br /> 7. PROVIDE (2) 'B-LINE' 1/2" W/ RETAINING BOLTS <br /> ADJUSTABLE THREADED ROD RISERS LN 4. BELL OF 24" DIA CONIC. JOB NO. 19720 <br /> WITH NUTS. PIPE <br /> 5 5. SEAL AROUND PIPE <br /> SHEET TITLE <br /> 6. CONDENSATE DRAIN <br /> 7 Z 5 LINE. PITCH 1/8"/LIN. <br /> FT BELOW GRADE. LINE <br /> F6 SHALL ENTER DRYWELL PLUMBING <br /> 4 M A MIN. OF 3" ABOVE <br /> 4 GRAVEL. DETAILS <br /> 7. GRAVEL BED <br /> 3 2 N <br /> 7 <br /> ISOMETRIC VIEW <br /> MEP Et FS / Sustainability / Cx) Q�pFESS/pay SHEET NO. <br /> � <br /> NTS NTS 1209 Pleasant Grove Blvd. <br /> TYP. PIPE SUPPORT ON ROOF 13 DRYWELL DETAIL 9 Roseville, CA 95678 <br /> p 916-771-0778 <br /> REN. 12-31-21 P -0 , 2 <br /> CONSULTING www.lpengineers.com `s�q HAN\CP���F <br /> Project Navigator P:\I -Project file5\20 19 LP Projects\19-206 I Meehleis- Tokay NS Gym\Mechanical\MP Sheets\192305_PO_2 (Plumb Details).dwg 113012020 2: 15 PM <br /> ENGINEERS Job#: 19-2061 F OF CAL\FO <br /> 192305_PO_2 (Plumb Detoils).dwg 01/30/20 2:15:55pm Ashton <br />