Laserfiche WebLink
SYSTEM SET-UP REPORT (Page 2) <br /> T 2:Midgrade_Unlead T s: rernum—U iUrrlead <br /> PRODUCT CODE C LEAK TEST METHOD <br /> THERMAL COEFF : .gg07p0 PRODUCT CODE B - - - - - - - - - - - - OUTPUT RELAY SETUP <br /> TANK DIAMETER 92.p0 THERMAL COEFF : .0007OO TEST ON DATE : ALL TANK - - - - - - - - - <br /> TANK PROFILE 4 PTS TANK DIAMETER 92.00 DEC 22, 1999 <br /> FULL VOL 9684 TANK PROFILE 4 PTS START TIME DISABLED R 1 :REG UNL <br /> 69.0 INCH VOL 8079 FULL VOL 7841 TEST RATE :0.20 GAL,,HR TYPE: <br /> 46.0 INCH VOL 5061 69.0 INCH VOL 6554 DURATION 2 HOURS STANDARD <br /> 23.0 INCH VOL 1973 46.0 INCH VOL 4099 NORMALLY CLOSED <br /> 23.0 INCH VOL 1585 TST EARLY STOP:DISABLED <br /> TANK #: 1 <br /> FLOAT SIZE: 2.0 IN. LEAK TEST REPORT FORMAT <br /> FLOAT SIZE: 4.0 IN. NORMAL <br /> WATER WARNING 30 LIQUID SENSOR ALMS <br /> HIGH WATER LIMIT: 5..0 WATER WARNING 3.0 L I :FUEL ALARM <br /> HIGH WATER LIMIT: 5.0 L 7:FUEL ALARM <br /> MAX OR LABEL VOL: 9684 L B:FUEL ALARM <br /> OVERFILL LIMIT 90,% MAX OR LABEL VOL: 7841 L 9:FUEL ALARM <br /> 8715 OVERFILL, LIMIT 90"% L10:FUEL ALARM <br /> HIGH PRODUCT95r 7056 L I :SENSOR OUT ALARM <br /> 9199 HIGH PRODUCT 95% L 7:SENSOR OUT ALARM <br /> DELIVERY LIMIT 200 7449 L 8:SENSOR OUT ALARM <br /> 1936 DELIVERY LIMIT 20% L 9:SENSOR OUT ALARM <br /> 1568 L10:SENSOR OUT ALARM <br /> LOW PRODUCT 1000 LIQUID SENSOR SETUP L I :SHORT ALARM <br /> LEAK ALARM LIMIT: 99 LOW PRODUCT 800 - -- - - - - - - - - - - L 7:SHORT ALARM <br /> SUDDEN LOSS LIMIT: 99 LEAK ALARM LIMIT: 99 L 8:SHORT ALARM <br /> TANK TILT 0.00 SUDDEN LOSS LIMIT: 99 L I :UNL SUMP L 9:SHORT ALARM <br /> PROBE OFFSET 0.00 TANK TILT 0.00 TRI-STATE (SINGLE FLOAT) L10:SHORT ALARM <br /> PROBE OFFSET 0.00 CATEGORY : STP SUMP <br /> ISD SITE ALARMS <br /> SIPHON MANIFOLDED TANKS ISD GROSS FRES FAIL <br /> Tri: NONE SIPHON MANIFOLDED TANKS L 2:PLUS SUMP ISD DEGRD PRES FAIL <br /> LINE MANIFOLDED TANKS TO: NONE TRI-STATE (SINGLE FLOAT) ISD VAPOR LEAK FAIL <br /> T#: NONE LINE MANIFOLDED TANKS CATEGORY : STP SUMP ISD VP PRES FAIL <br /> T#: NONE ISD VP STATUS FAIL <br /> LEAK MIN PERIODIC: 0% L 3:PRE SUMP ISD HOSE ALARMS <br /> 0 LEAK MIN PERIODIC: 0%% TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL <br /> 0 CATEGORY : STP SUMP <br /> LEAK MIN ANNUAL 0.% PERIODIC. TEST TYPE R 2:PLUS UNL <br /> 0 STANDARD TYPE: <br /> L 4:UNL ANL STANDARD <br /> PERIODIC TEST FAIL TRI-STATE (SINGLE FLOAT) NORMALLY CLOSED <br /> PERIODIC TEST TYPE ALARM DISABLED CATEGORY : ANNULAR SPACE <br /> STANDARD GROSS TEST FAIL TANK #: 2 <br /> HNNUAL TEST FAIL ALARM DISABLED <br /> ALARM DISABLED L 5:PLUS ANL IN-TANK ALARMS <br /> PER TEST AVERAGING: OFF TRI-STATE (SINGLE FLOAT) T 2:PROBE OUT <br /> PERIODIC. TEST FAIL TANK TEST NOTIFY: OFF CATEGORY : ANNULAR SPACE LIQUID SENSOR ALMS <br /> ALARM DISABLED L 2:FUEL ALARM <br /> GROSS TEST FAIL TNK TST SIPHON BREAKOFF L 7:FUEL ALARM <br /> ALARM DISABLED L 6:PRE ANL L 8:FUEL ALARM <br /> DELIVERY DELAY 2 MIN TRI-STATE (SINGLE FLOAT) L 9:FUEL ALARM <br /> ANN TEST AVERAGING: OFF PUMP THRESHOLD 10.00% CATEGORY : ANNULAR SPACE LIO:FOEL ALARM <br /> PER TEST AVERAGING: OFF L 2:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM <br /> TANK TEST NOTIFY: OFF L 8:SENSOR OUT ALARM <br /> L 7:DISP 1-2 L 9:SENSOR OUT ALARM <br /> TNK TST SIPHON BREAKOFF TRI-STATE (SINGLE FLOAT) L10:SENSOR OUT ALARM <br /> CATEGORY : DISPENSER PAN L 2:SHORT ALARM <br /> DELIVERY DELAY 2 MIN L 7:SHORT ALARM <br /> PUMP THRESHOLD 10.00:% L B:SHORT ALARM <br /> L 9:SHORT ALARM <br /> L 8:DISP 3-4 L10:SHORT ALARM <br /> TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : DISPENSER PAN ISD SITE ALARMS <br /> ISD GROSS PRES FAIL <br /> ISD DEGRD FRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> L 9:DISP 5-6 ISD VP PRES FAIL <br /> TRI-STATE (SINGLE FLOAT) ISD VP STATUS FAIL <br /> CATEGORY : DISPENSER PAN <br /> ISD HOSE ALARMS <br /> ALL:FLOW COLLECT FAIL <br /> LIO:DISP 7-6 R 3:PRE UNL <br /> TRI-STATE (SINGLE FLOAT) TYPE: <br /> CATEGORY : DISPENSER PAN STANDARD <br /> NORMALLY CLOSED <br /> ©2018 Walton Engineering,Inc. <br />