My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ARBOR
>
9409
>
2200 - Hazardous Waste Program
>
PR0542633
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2020 12:08:47 PM
Creation date
8/19/2020 11:23:34 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0542633
PE
2226
FACILITY_ID
FA0024521
FACILITY_NAME
Penske Truck Leasing Co., LP
STREET_NUMBER
9409
Direction
W
STREET_NAME
ARBOR
STREET_TYPE
Ave
City
Tracy
Zip
95304
CURRENT_STATUS
01
SITE_LOCATION
9409 W Arbor Ave
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Penske Truck Leasing Co., LP 9409 W Arbor Ave, Tracy January 09, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 66262.34(d)(2) No modified contingency plan. <br /> An emergency coordinator and modified contingency plan information is lacking. There must be at least one <br /> emergency coordinator on site or on call to coordinate emergency response measures, and the following <br /> information must be posted by a phone: the name and phone number of the emergency coordinator; location of fire <br /> extinguishers, spill control equipment, and if present,fire alarm; and the phone number of the fire department, <br /> unless the facility has a direct alarm. Immediately appoint an emergency coordinator and post the required <br /> information by a phone. A form is provided that can be used for this purpose. <br /> This is a minor violation. <br /> 110 CCR 66262.40(a) Failed to keep signed copy of manifests from the designated facility for three years. <br /> Manifest numbers 006687299SKS (11/13/18)and 006462428SKS (05/24/18)were found without a signed off copy <br /> from the destination facility. Hazardous waste generators shall retain copies of all manifests signed off by the <br /> destination facility on site for three years and have them readily available for review. If the generator did not receive <br /> a copy of the manifest with the handwritten signature of the owner or operator of the facility to which the generator's <br /> waste was submitted within 60 days of the date the waste was accepted by the initial transporter,the generator shall <br /> submit a legible copy of the missing manifest, with some indication that the generator has not received confirmation <br /> of delivery. This information shall be submitted to: <br /> DTSC Report Repository <br /> Generator Information Services Section <br /> P.O. Box 806 <br /> Sacramento, CA 95812-0806 <br /> Immediately locate a copy of the missing manifests or prepare and submit the required information to DTSC. <br /> Submit to the EHD a copy of the signed off copy of the manifest or a copy of the information submitted to DTSC. <br /> This is a Class II violation. <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems, spill control, or decontamination <br /> equipment. <br /> Secondary containment pallet for the lead acid batteries found at the back of the shop was observed half full with an <br /> unknown liquid. Bottled eye wash station at the back of the shop was observed with an eye wash bottle expired on <br /> June 2018. Eye wash station by the locker room was observed to be empty with no eye wash fluid. All facility <br /> communications or alarm systems, fire protection equipment, spill control equipment, and decontamination <br /> equipment, where required, shall be tested and maintained as necessary to assure its proper operation in time of <br /> emergency. Immediately begin this practice. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 8th 2019. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> FA0024521 PR0542633 SCO01 01/09/2019 <br /> EHD 22-01 Rev.09/27/2016 Page 4 of 5 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.