My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
2430
>
2200 - Hazardous Waste Program
>
PR0539411
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/28/2020 3:10:33 PM
Creation date
8/19/2020 2:56:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0539411
PE
2220
FACILITY_ID
FA0006844
FACILITY_NAME
FOOD 4 LESS
STREET_NUMBER
2430
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
05814044
CURRENT_STATUS
01
SITE_LOCATION
2430 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q U I N Environmental Health Department <br /> —CC.UUNIY <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> FOOD 4 LESS 2430 W KETTLEMAN LN LODI August 13, 2020 <br /> Treatment,Transport and Disposal <br /> 206 HSC 25160.2(c)(2) Waste stream or generator not eligible to use consolidated manifesting procedure o V o R n COS <br /> 207 HSC 25144.6(b) Failure to properly manage reusable soiled textile materials o V o R o COS <br /> 208 HSC 25200.3.1(c) Failure of laboratory to comply with hazardous waste treatment requirements in V o R o COS <br /> 209 CCR 66262.34(d)(2) Failure to remove all hazardous waste from tanks,containers and containment upon facility closure n V o R o COS <br /> Preparedness and Prevention <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste o V o R n COS <br /> 302 CCR 66262.34(d)(2) Failed to maintain required emergency equipment n V o R o COS <br /> 303 CCR 66262.34(d)(2) Failed to maintain all communication or alarm systems,spill control,or decontamination equipment o V o R o COS <br /> 304 CCR 66262.34(d)(2) Failed to maintain adequate aisle space for unobstructed response to emergencies n V o R n COS <br /> Container Management <br /> 401 CCR 66262.34(d)(2) Failed to store hazardous waste in a container that is in good condition o V n R o COS <br /> 402 CCR 66262.34(d)(2) Failed to store hazardous waste in a compatible container o V o R o COS <br /> 403 CCR 66262.34(d)(2) Failed to keep hazardous waste containers closed except when adding or removing hazardous waste o V o R o COS <br /> 404 CCR 66262.34(d)(2) Failed to inspect hazardous waste storage areas at least weekly o V o R o COS <br /> 405 CCR 66262.34(d)(2) Failed to manage incompatible wastes in containers properly o V o R o COS <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied o V o R o COS <br /> 407 CCR 66262.34(e)(1)(A) Satellite accumulation container not located near point of generation or under control of operator in V in R o COS <br /> 408 CCR 66262.34(e)(2) Satellite accumulation exceeded 55 gallons of HW(or one quart of acutely HW)per waste stream n V n R n COS <br /> Tank Management <br /> 501 CCR 66262.34(d)(2) No overfill prevention device on continuously fed hazardous waste tank o V o R c COS <br /> 502 CCR 66262.34(d)(2) Tank system inspections of discharge systems,monitoring equipment,and tank levels not done daily o V o R o COS <br /> 503 CCR 66262.34(d)(2) Tank system inspections of construction materials,fixtures,and surrounding areas not done weekly o V o R o COS <br /> 504 CCR 66262.34(d)(2) Failed to maintain at least two feet of freeboard in uncovered tank with no secondary containment o V o R o COS <br /> 505 CCR 66262.34(f) Failed to completely label stationary hazardous waste tanks o V o R n COS <br /> Labeling and Storage <br /> 601 CCR 66262.34(d) Stored hazardous waste onsite greater than 180 days o V o R o COS <br /> 602 CCR 66262.34(e)(1)(B) Stored satellite accumulated waste on site longer than one year or 180 days after fill date o V o R o COS <br /> 603 CCR 66262.34(e)(1)(C) Failed to mark initial accumulation start date on satellite containers o V o R o COS <br /> 604 CCR 66262.34(e)(3) Failed to mark satellite containers with date filled within three days o V n R o COS <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste o V o R o COS <br /> 606 CCR 66266.81(a)(3) Failed to meet lead acid battery storage requirements for hazardous waste management exemption o V o R o COS <br /> 607 CCR 66266.81(b) Damaged lead acid batteries not properly managed and labeled o V o R o COS <br /> 608 CCR 66266.130 Failed to properly manage used oil and fuel filters o V o R o COS <br /> 609 HSC 25143.2,25143.9 Failed to meet requirements for claimed excluded recyclable materials o V o R o COS <br /> FA0006844 PRO539411 SC001 08/13/2020 <br /> EHD 22-01 Rev.8/11/2020 Page 2 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.