Laserfiche WebLink
Hazardous Waste Tank System <br /> Written Assessment per CCR Title 22 February <br /> Jiffy Lube Store#3808, 3276 W. Grant Line Rd. 2019 <br /> Tracy, CA 95304 <br /> Tank Assessment Page Tank Name/marking: Used Antifreeze Tank <br /> Tankage: 1year <br /> Manufacturer: Gemini, Peabody Tank <br /> Remaining service life: 25 years, inspect in 5 <br /> years <br /> Tank Construction: <br /> Shape: Cylindrical Closed Top, Flat Bottom Integral Secondary <br /> Containment <br /> Orientation: Vertical <br /> Location (above/below ground): Above ground <br /> Material of construction: HDPE <br /> Thickness and method Waste to determine: 0.18" by UTG <br /> Lining material & thickness (if applicable): N A. <br /> Corrosion Protection equipment: Compatible <br /> Structural support: The tank rests on concrete foundation. <br /> Other identifying features: Natural White <br /> Piping and ancillary equipment (pumps): NA, Gravity <br /> Piping Material of Construction: NA <br /> Piping Diameter: NA <br /> Pump location(s): NA <br /> Pump type(s)/capacities: NA <br /> Overfill Protection: Audible alarm when tank reaches 90% of capacity. The <br /> system was tested and found to be operating. <br /> Material Storage: <br /> Material and characteristics: Waste Antifreeze, Toxic <br /> Specific Gravity: 1.05 <br /> Operating Capacity: 100 gallons <br /> Strandberg Associates 1(866) 388-040, lohn(a�strandbergassociates.com 14 <br />