Laserfiche WebLink
pME� � Environmental Health Department <br /> SANJUAQUIN <br /> .—C 0U N T Y------ <br /> Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TUFF BOY SALES INC 3870 W YOSEMITE AVE, LATHROP October 22, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 203 HSC 25189.5(c)Transported or caused transportation of hazardous waste to an unauthorized point. <br /> During 2017 several waste streams were disposed of on a CESQG receipt from Stericycle. This site generates <br /> more than 1 00k of hazardous waste per month so it is ineligible to dispose of waste on a CESQG receipt. The <br /> wastes disposed of with a CESQG receipt were: <br /> -2/23/2017 Oil based paint(190 pounds) <br /> -8/16/2017 Oil based paint(40 pounds) <br /> -4/19/2017 Detergent(220 pounds) <br /> -6/21/2017 Spent silicone(100 pounds) <br /> -8/16/2017 Waste adhesive(100 pounds) <br /> -12/6/2017 Waste adhesive(100 pounds) <br /> Transportation of hazardous waste shall be performed only a person that holds a valid registration issued by the <br /> Department of Toxic Substances Control to transport hazardous waste. Immediately begin using a registered <br /> hazardous waste hauler to transport any generated hazardous wastes. <br /> This is a Class If violation. <br /> 301 CCR 66262.34(d)(2) Facility not maintained to minimize the release of a hazardous waste. <br /> -Three black metal 55 gallon drums of used oil were observed in the hazardous waste storage area with puddles of <br /> oil and a rag saturated in oil on the tops of the drums. <br /> -One black metal 55 gallon drum of used oil located on the outside south wall of the hazardous waste storage area <br /> was observed with a puddle of oil on the top of the drum. <br /> Facilities shall be maintained and operated to minimize the possibility of a fire,explosion, or release of hazardous <br /> waste to air, soil, or surface water which could threaten human health or the environment. Immediately clean up the <br /> used oil and manage according to Title 22 hazardous waste regulations. Submit a statement and supporting <br /> documentation explaining how this waste was managed. <br /> This is a minor violation. <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied. <br /> -One empty black metal 55 gallon drum was observed on the south outside wall of the hazardous waste storage <br /> area without the words"empty"and a date. <br /> -Twelve empty metal 55 gallon drums were observed outside the grease storage shed without the words"empty" <br /> and a date. <br /> Containers larger than five gallons that previously held a hazardous material shall be marked with the date they <br /> were emptied and managed within one year of being emptied. Immediately mark and manage all empty containers <br /> per this section. <br /> This is a minor violation. <br /> FA0009612 PR0513927 SCO01 10/22/2018 <br /> EHD 22-01 Rev.09/27/2018 Page 4 of 6 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />