Laserfiche WebLink
aU'" �z SAN JOAQUIN p <br /> °mac° Environmental Health Department <br /> tn ' COUNTY <br /> Linda Turkatte, REHS , Director <br /> cgt) FoGreatness grows here . Kasey Foley, REHS , Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Rodney Estrada , REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> June 7 , 2019 <br /> Megan Mitchell <br /> Elite IV Contractors <br /> 2535 Wigwam Dr. <br /> Stockton , CA 95205 <br /> Re : Sheriff' s Operations Ctr #2 SR0080343 <br /> 7000 N . Michael Canlis Blvd . , French Camp 95231 <br /> The San Joaquin County Environmental Health Department ( EHD ) has completed the review of the <br /> application for a permit to replace the diesel direct- bury spill bucket and drop tube on the underground <br /> storage tank ( UST) system at the above noted address . The permit has been approved with the <br /> following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Stacy Rivera at (209 ) 468-3440 to arrange the following inspection appointments ( a <br /> 48 - hour notice is required for inspection appointments) . Please be aware that inspections for <br /> emergency work must be scheduled within five days of permit approval . <br /> a . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of ball floats absent or located at a level that will not interfere with drop tube <br /> functionality . <br /> b . Corrosion protection : Verify corrosion protection for direct bury spill bucket prior to <br /> backfilling . <br /> c . Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic test ( or <br /> equivalent) . Proper drainage must also be verified . <br /> Please be aware that the facility cannot receive fuel in the diesel tank prior to the EHD <br /> inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> c . Possesses a valid , current certificate of training from the manufacturer(s ) of the <br /> component (s ) being tested , repaired , or serviced . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 F 209 464 -0138 1 www . sjcehd . com <br />