Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM ( Pagel of 6) <br /> This form must be used to document testing and servicing of underground storage tank ( UST) monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> a ncy regulating the USTs within 30 days of the date of the monitoring system certification . <br /> I , FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10181433 12/ 19/ 18 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) Building # <br /> March Ln 76 <br /> Business Site Address City ZIP Code <br /> 2701 West March Ln . Stockton 95219 <br /> 11 . UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone # <br /> Service Station Systems (408 ) 971 -2445 <br /> Mailing Address <br /> 680 Quinn Ave , San Jose , Ca 95112 <br /> Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification) <br /> Kristopher Bell <br /> Contractor / Tank Tester License # ICC Certification # ICC Certification Expiration Date <br /> 485184 8833000 7122/2020 <br /> Monitoring System Training and Certifications List all applicable certifications. Ex iration Date <br /> 4/12/2019 <br /> Veeder Root <br /> 10!31 !2020 <br /> V. M . I <br /> III . RESULTS OF TESTING / SERVICING <br /> indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> ® <br /> Monitoring System SetaruR ® Alarm .History Report <br /> Was any monitoring equipment replaced? ❑ © ❑ <br /> (If `Yes, " identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) <br /> Was damage, debris , or liquid found inside any secondary containment systems? (a ❑ ❑ <br /> (if "Yes, " describe what was found in section IV below,) <br /> Is all monitoring equipment operational per manufacturer's specifications ? ❑ ❑ <br /> (if Wo, " describe why in section IV below.) <br /> IV. COMMENTS <br /> If directed to use this section, describe how and when the issues were or will be corrected. <br /> Removed Liquid from all STP Sumps . <br /> CE <br /> JAN 15 2019 <br /> I clp0: T P C)PPtxn° r k <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment identified In this document was inspected/serviced in accordance with California Code of <br /> Regulations , Title 23 , Division 3 , Chapter 16 , Section 2638 and all information contained herein is true and accurate , Attached to <br /> this certification is information (e. g ., manufacturers ' checklists , monitoring system set-up , alarm history report, etc .) necessary <br /> to verify that this information and the site plan showing the layout of UST system is complete and accurate . <br /> UST Service Technician Signature <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, Y = Yes, N = No, NA = Not Applicable <br />