My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 12:55:35 PM
Creation date
8/20/2020 2:15:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1 ) <br /> Type of Action © installation Inspection ❑ Repair Inspection [:136 Month Inspection <br /> 1 . FACILITY INFORMATION <br /> CERS ID 10181433 Date of Overfill Prevention Equipment Inspection <br /> 5!9/19 <br /> Business Name (Same as Facility Name or DBA-Doing Business As) <br /> Unocal255886 <br /> Business Site Address City ZIP Code <br /> 2701 West March lane Stockton 95219 <br /> IL UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) Phone # <br /> Eusebio Sousa 1 (707) 545-5522 <br /> Contractor / Tank Tester License # `ICC # 77/18/19 <br /> Certification Expiration Date <br /> Able Maintenance, Inc, - 312844 5454516-UT <br /> Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br /> OPW EVR Phase 1 - UST 100414 <br /> Ill. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ® Manufacturer Guidelines (Specify): <br /> Used : OPW 71SO <br /> ❑ Industry Code or Engineering Standard (Specify): <br /> ❑ Engineered Method (Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br /> TANK ID : (By tank number, stored product, etc.) 87 91 <br /> What is the tank Inside diameter? (inches) 111 .5" 111 .5" <br /> Is the fill piping secondarily contained? ® Yes ❑ No JZ] Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Is the vent piping secondarily contained? ® Yes ❑ No ® Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW <br /> 71 SO 71 SO <br /> What is the overfill prevention equipment response ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow ❑ Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ® Restricts Flow ® Restricts Flow ❑ Restricts Flow [I Restricts Flow <br /> ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm ❑ AN Alarm <br /> Are flow restrictors installed on vent piping? ® Yes ❑ No M Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> At what level In the tank is the overfill prevention set <br /> to activate? (inches from bottom of tank.) 97 , 75" 97 .75" <br /> What Is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 92 , 9% 92 .9% <br /> Is the overfill prevention in proper operating condition ® Yes ® Yes ❑ Yes ❑ Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑ No (Specify in V) ❑ No (Specilyin V) ❑ No (Specify in V.) ❑ No (Speciiyin V) <br /> IV . SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ® Pass ❑ Fail ® Pass ❑ Fa(I ❑ Pass ❑ Fail =0P s ❑ Fail <br /> V . COMMENTS <br /> Any items marked "Fail° must be explained in this section. Any additional comments may also be provided here. <br /> Installed New Drop Tubes - Tested & Passed. <br /> VI . CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipmentwas inspected in accordance with California Code of Regulations, Title 23, <br /> Division 3 , Chapter 16 , Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates, additional copies of this page may be attached. <br /> CERS = CaKomia Environmental Reporting System, ID = Identification, UST = Underground Storage Tank, ICC = international Code Council, AN Audible and Visual <br />
The URL can be used to link to this page