My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PERSHING
>
4501
>
2300 - Underground Storage Tank Program
>
PR0231233
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 10:29:31 AM
Creation date
8/20/2020 2:53:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231233
PE
2361
FACILITY_ID
FA0002479
FACILITY_NAME
7-ELEVEN INC #17334
STREET_NUMBER
4501
Direction
N
STREET_NAME
PERSHING
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11017004
CURRENT_STATUS
01
SITE_LOCATION
4501 N PERSHING AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AN ]OA UIN <br />C)U NTY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />7 -ELEVEN INC #17334 <br />4501 N PERSHING AVE, STOCKTON <br />September 20, 2019 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR- Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b)(1-2) Failure to maintain monitoring, maintenance, and follow up action records. <br />The overfill prevention testing conducted on 7/27/2018 a copy of the test results were not found on site during <br />inspection. <br />These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br />observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br />monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br />reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br />site and submit copies to the EHD. <br />This is a minor violation. <br />205 <br />CCR 2712(1), 2634(e) Failure to submit a current UST Response Plan and have it available onsite. <br />An approved/current copy of the response plans were not available for inspection. A copy of these plans shall be <br />accessible on site at all times. Immediately locate and retain a copy on site. <br />This is a minor violation. <br />306 <br />CCR 2630(d), 2641(a) Monitoring equipment is not installed or maintained to detect a leak at the earliest <br />opportunity. <br />The 87 product submersible turbine pump (STP) sump 208 sensor failed to activate an audible and visual alarm <br />when tested to ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to <br />activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The sensor <br />was replaced by the service technician and retested during the inspection. <br />This was corrected on site <br />This is a Class II violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by October 20, 2019 . <br />Starting September 1, 2018, all in -office CERS help will be provided at EHD hourly rate ($152). To schedule an <br />appointment, please call (209) 468-3420. <br />Documents provided Return to Compliance Certification Form and a list of scheduled approve free CUPA <br />classes. <br />FA0002479 PR0231233 SCO01 09/20/2019 <br />EHD 23-01 Rev. 8/22/2019 Page 5 of 6 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.