My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1756
>
2300 - Underground Storage Tank Program
>
PR0231300
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2021 12:52:26 PM
Creation date
8/20/2020 3:21:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231300
PE
2361
FACILITY_ID
FA0001858
FACILITY_NAME
MY MINI MART
STREET_NUMBER
1756
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11721005
CURRENT_STATUS
01
SITE_LOCATION
1756 N WILSON WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S A N-J OQQ U S N Environmental Health Department <br /> l .. COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> MY MINI MART 209 941-2246 June 06 2019 <br /> Facility Address: CERS ID: <br /> 1756 N WILSON WAY STOCKTON CA 95205 10180819 <br /> Inspection Contact: Title: Phone: <br /> Ashish Boveja Owner 209 941-2246 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION -Operatinq Permit 12361 - UST FACILITY <br /> Consent For: IConsent Given By: <br /> Z Inspection 0 Photos N Samples I All ssa Delsied Manager <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> David Winkler 03/31/2020 Zane Nimmo 02/25/2020 <br /> Service Technician Manufacturer's Training <br /> TT 03/31/20; Incon 11/30/20; OPW,03/14/20; VMI, 11/10/19 <br /> CCR=Title 23 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284; CCR Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees o V ❑R o COS <br /> 2711(d) <br /> 102 HSC 25284(a)(3)(A)/ No written agreement between tank owner and tank operator to monitor the tank system ❑V o R o COS <br /> (B) <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents ❑V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current ❑V o R o COS <br /> 105 CCR 2632(d)(1), Failed to have an approved UST monitoring plan ■V o R o COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V o R ❑COS <br /> 2634(e) <br /> 107 CCR 2632(d),2641(h), Plot plan/site map not submitted or failed to completely show where monitoring is performed o V o R ❑COS <br /> 2711(a) <br /> 108 CCR 2637,2638(e), Failed to notify the EHD 48 hours prior to conducting testing :71 V o R o COS <br /> 2643(g) <br /> 109 CCR 2637(a-d),2712 Failed to test secondary containment,or failed to maintain test records for 36 months o V o R c COS <br /> 110 CCR 2637(e),2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test o V o R c COS <br /> 111 CCR 2638,26410), Failed to test monitoring and leak detection equipment every 12 months o V o R o COS <br /> 2715(f) <br /> 112 HSC 25293 Failure to maintain UST records to enable the UPA to determine whether the UST is in compliance o V o R ❑COS <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the test o V c R o COS <br /> 114 CCR 2636(f)(3), No 0.1 gph annual line integrity test for pressurized piping,or within 30 days after repair o V c R o COS <br /> 2643(c)(3) <br /> 115 CCR 2715(a)(1)(B), "Designated Underground Storage Tank Operator Identification Form"not submitted within 30 days o V o R e COS <br /> 2715(a)(3) <br /> 116 CCR 2715 Designated operator, service tech or installer did not possess current ICC certification o V o R o COS <br /> 117 CCR 2663, 2712(b)(6) Failure to comply with tank lining, recordkeeping,and inspection requirements o V o R o COS <br /> 118 CCR 2715(a)(1)(A), Failure to submit the"Underground Storage Tank Statement of Understanding and Compliance Form" o V c R ❑COS <br /> 2715(a)(2) <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented o V o R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V o R o COS <br /> FA0001858 PR0231300 SCO01 06/06/2019 <br /> EHD 23-01 Rev.09/28/2018 Page 1 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.