My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 4:36:01 PM
Creation date
8/25/2020 11:10:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PEI/RP1200 - 17 <br /> 12.3 Procedure. <br /> 12 D0CUIMENTAT 10l� 1. Perform test and/or inspection services . <br /> 12 . 1 General . Documentation showing the date and 2. Document results. <br /> type of testing done to verify spill, overfill, leak detec- 3 . Review and approve results for accuracy. <br /> tion, secondary containment equipment, shear valve and 4. Provide results to customer in accordance with time <br /> emergency stop operation should be available for review frames set by the AHJ. <br /> according to the requirements of the authority having <br /> jurisdiction (AHJ) . 5. Store results electronically, and make them easily <br /> available for inspection and backup systems <br /> 12.2 Purpose. Testers and inspectors shall provide accordingly. <br /> adequate documentation of the services that have been <br /> performed on underground storage tank (UST) systems. Sample forms are provided in Appendix C of this <br /> All test results should include a detailed description of document. <br /> the tests and inspections performed to back up the pass/ <br /> fail criteria. This includes but is not limited to : test start <br /> and stop times ; vacuum levels; liquid levels; data gath. <br /> ered while conducting tests and inspections ; and photos <br /> when applicable. In addition, test and inspection results <br /> shall be made available to the responsible persons for the <br /> UST systems in a timely manner and within time frames <br /> required by the AHJ. Results shall be maintained for <br /> appropriate time frames by the tester/inspector as well as <br /> by the owner/operator. Electronic data can be maintained <br /> indefinitely and should not be discarded. <br /> i <br /> pei .org <br /> i <br />