My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 4:36:01 PM
Creation date
8/25/2020 11:10:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
133
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br /> Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities <br /> 4.3 .4 Test Conditions . The primary contain- 4.3.9 Test Procedure . <br /> ment may contain any level of product. Determine 1. Remove any sensor that may be installed in the <br /> whether the groundwater depth is above the bottom tank interstitial space. <br /> of the tank. Consult specific manufacturer's proce- <br /> dures in regards to groundwater and performing the 2. Determine and record the groundwater level. <br /> test. No bulk deliveries shall occur within 8 hours 3 . Add test liquid to the tank interstitial <br /> prior to conducting or during the test. No dispens- space, bringing the fluid level into the riser <br /> ing may occur during the test. (standpipe) to the appropriate level based on <br /> 4.3. 5 Preparation . Determine the volume of the manufacturer ' s written procedure, <br /> the tank and identify the test being performed. 4 . Document the starting level and start time of <br /> Tank volume information is available from facility the test. <br /> records or the ATG readout. Prepare a monitoring <br /> S. Start the time-measurement device . <br /> fluid solution to add to the interstitial space. <br /> 6 . Wait the appropriate time according to the <br /> 4.3 . 6 Steel Tanks. Liquid-filled (hydrostatic) manufacturer ' s test procedure. <br /> tests on steel tanks require the same fluid as the <br /> monitoring fluid. Contact the manufacturer for 7. Document the ending level and ending time of <br /> instructions. the test. <br /> 4. 3 . 7 Fiberglass Tanks. Determine tank size S. Determine and record the groundwater level . <br /> and diameter and apply the appropriate method. 9 . Remove liquid added to the tank interstitial <br /> space, and restore the liquid level in the tank <br /> 4.3,8 Test Equipment . Test equipment shall interstitial to normal operating condition. <br /> include: <br /> 10. Reinstall the sensor so that it is installed within <br /> • monitoring fluid ; manufacturer ' s specifications. <br /> • stopwatch or other time-measurement device <br /> 4.3.10 Pass/Fail Criteria. Compare the data to <br /> capable of measuring a 1-second increment; <br /> the manufacturers pass/fail criteria in Appendix A <br /> • tape measure. to determine if the tank has passed the test. <br />{t� <br /> t <br /> peLorg <br />
The URL can be used to link to this page
Your browser does not support the video tag.