Laserfiche WebLink
)0 N VAN J 0 A Q U I N Environmental Health Department <br /> . ; COUNTY Linda Turkatte , RENS , Director <br /> Greatness grows here . Kase y Foley, REHS, Assistant Director <br /> PROGRAM COORDINATORS <br /> Robert McClellon, REHS <br /> Jeff Carruesco, REHS , RDI <br /> Rodney Estrada, REHS <br /> Willy Ng , REHS <br /> Muniappa Naidu, REHS <br /> December 05 , 2018 <br /> MICHAEL WALTON n <br /> A� 1a <br /> WALTON ENGINEERING <br /> PO BOX 1025 <br /> SACRAMENTO , CA 95691 <br /> Re : TESORO ( MOBIL) 68152 SR0079789 <br /> 401 W KETTLEMAN LN <br /> LODI , CA 95240 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to replace directly buried 91 -product spill container with OPW (OPW 1 C-3112D ) 5 <br /> gallon spill container and replace existing 91 -product overfill prevention valve with new OPW-71 SO <br /> overfill protection valves on the underground storage tank ( UST) system at the above noted address . <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for any <br /> applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Zuna Barker at (209) 953-7311 to arrange the following appointments (a 48-hour notice is <br /> required for inspection appointments) . <br /> • Overfill prevention verification : Measurement of drop tubes to verify 95% tank volume shut off. Complete <br /> and accurate drop tube calculations must be provided prior to this inspection . If ball floats are installed , <br /> it must be verified that they don 't interfere with the installed flapper valve . <br /> • Spill bucket test: Verify minimum 5-gallon capacity and pass a one hour hydrostatic test (or <br /> equivalent) . Proper drainage must also be verified . <br /> • Corrosion protection : Verify corrosion protection for direct bury spill bucket prior to backfilling . <br /> 4 . Since concrete will be broken near the tank, a secondary containment test must be performed on the <br /> tank once concrete is poured in accordance with the manufacturer' s guidelines . <br /> Please be aware that the facility cannot receive fuel in the tank prior to the EHD inspection <br /> and approval . <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />