401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2021 1:25:02 PM
Creation date
8/25/2020 12:44:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In : <br /> Time Out: <br /> San Joaquin County <br /> y Environmental Health Department <br /> 1868 East Hazelton Avenue , Stockton , CA 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 464-0138 Web : www. segov. org/ehd <br /> gLIPa,R�: <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: TESORO ( MOBIL) 68152 Date : 12/ 19/2018 <br /> Address: 401 W KETTLEMAN LN , LODI 95240 <br /> Requestor: MICHAEL WALTON , WALTON ENGINEERING Telephone : (916) 373- 1165 <br /> Program Element: 2308 - UST RETROFIT Request #: SR0079789 <br /> Inspection Type: 298 . UST RETROFIT REPAIR INSPECTION <br /> Onsite Service Technician : Rey Hernandez ICC Service Tech/Installer Exp , Date: 05/08/2019 <br /> Manufacturer training : OPW, 01 /01 /19 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site to verify corrosion protection for the 91 product direct bury spill container prior to backfilling . The riser pipe was coated <br /> with 2 inch , 20 mil tape to protect it from the backfill , the rest of the spill container meets corrosion protection by isolation due <br /> to the material of the outside of the container. Measurement of the Overfill prevention was verified to be set at 95% of the tank <br /> volume . Ball floats were removed from the vent lines to ensure that they do not interfere with the installed flapper valve. <br /> This service request is not completed at this time. A verification of a minimum 5 gallon capacity, a one hour hydrostatic test (or <br /> equivalent) along with proper drainage, and secondary containment testing on the 91 product tank must be verify in order for <br /> the facility to receive 91 product fuel . <br /> An inspection to complete the service request is schedule for 12/20/18 at 1lam , <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code. If a reinspection is required , fees will be assessed at the current hourly rate. <br /> Received by: �j Name and Title : Rey M Hernandez , Service Technicia <br /> EH Specialist: ZUNA BARKER Phone : (209) 953-7311 <br /> FA0003603 SR0079789 SC298 12/19/2018 <br /> EHD 23-01 Rev. 06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.