N GENERAL NOTES - FIRE ALARM GENERAL NOTES - LIGHTING GENERAL ELECTRICAL NOTES STANDARD ABBREVIATIONS ELECTRICAL SYMBOLS LEGEND V~, <br /> Iq 0 U <br /> A. FIRE ALARM SYSTEM AND FIRE ALARM DEVICE PLACEMENT LOCATIONS SHOWN FOR REFERENCE A. LOWER CASE LETTERS ON OR NEAR LIGHT FIXTURES INDICATE CONTROLLING SWITCHES. A. CODES: INSTALL ALL ELECTRICAL SYSTEMS IN ACCORDANCE WITH THE LATEST (D) DEMO ELECTRICAL LIGHTING SYMBOLS ELECTRICAL POWER SYMBOLS COMMUNICATION SYMBOLS , w <br /> _ ONLY. FIRE ALARM SYSTEM WILL BE DESIGN/BUILD UNDER DEFERRED SUBMITTAL AND SHALL BE SWITCH LEGS AND TRAVELERS MAY NOT ALWAYS BE SHOWN. ADOPTED EDITION OF THE CALIFORNIA ELECTRICAL CODE,CALIFORNIA BUILDING (E) EXISTING 1X4 LAY IN FIXTURE 208V OUTLET 1 DATA OUTLET WALL <br /> SUPPLIED FROM AN APPROVED SOURCE. DESIGN BUILD CONTRACTOR SHALL SUBMIT DESIGNS B. PROVIDE DEDICATED NEUTRAL(GROUNDED)CONDUCTOR FOR ALL LIGHTING CIRCUITS.NO CODE,CALIFORNIA RESIDENTIAL CODE,CALIFORNIA ENERGY CODE,AS WELL AS ALL (F) FUTURE <br /> AND SPECS FOR APPROVAL.THE FIRE WARNING SYSTEM MUST BE APPROVED BY THE FIRE MULTI-WIRE BRANCH CIRCUITS ARE ALLOWED. APPLICABLE STATE AND LOCAL CODES AND ORDINANCES. <br /> �0 ❑t <br /> � DEPARTMENT AND THE STATE FIRE MARSHALL BEFORE THE APPROVAL OF THE FINAL PLANS. C. CONNECT EMERGENCY/EXIT LIGHT FIXTURES AND OCCUPANCY SENSORS TO UN-SWITCHED B. COMPLETE INSTALLATION: PROVIDE ALL LABOR, MATERIALS, EQUIPMENT,TOOLS, (N) NEW 2X2 LAY-IN FIXTURE DUPLEX OUTLET DATA OUTLET IN FLOOR <br /> (R) RELOCATED r 1 <br /> N THE FIRE ALARM SYSTEM SHALL BE SUBMITTED UNDER A SEPARATE PERMIT AND COVER TO THE HOT PORTION OF CIRCUIT INDICATED. VERIFY FIXTURE INCLUDES MINIMUM 90 MINUTE ACCESSORIES, ETC.,NECESSARY TO ACCOMPLISH A COMPLETE ELECTRICAL SYSTEM 2X4 LAY IN FIXTURE DOUBLE DUPLEX OUTLET DATA OUTLET IN CEILING U <br /> O BUILDING DEPARTMENT BY A C-10 LICENSED FIRE ALARM CONTRACTOR. SEE TYPICAL FIRE BATTERY BACKUP. PROVIDE ADDITIONAL CONDUCTORS AS REQUIRED. PROVIDE ALL IN ACCORDANCE WITH THE PLANS TOGETHER WITH THE SPECIFICATIONS. AC ABOVE COUNTER,4 ABOVE BACKSPLASH <br /> M ALARM RISER DETAIL 7/E5.2. REQUIRED CONDUCTORS WHICH MAY NOT ALWAYS BE SHOWN. C. GROUNDING: GROUND ALL EQUIPMENT AND SYSTEM NEUTRAL IN ACCORDANCE AFF ABOVE FINISH FLOOR <br /> B. THESE DRAWINGS ARE PARTIALLY DIAGRAMMATIC, REFER TO ARCHITECTURAL DRAWINGS FOR D. ALL INTERIOR AND EXTERIOR LIGHTING SHALL BE CONTROLLED IN ACCORDANCE WITH TITLE WITH ARTICLE 250 OF THE CEC. A SEPARATE GROUND CONDUCTOR SHALL BE AFG ABOVE FINISH GRADE ESURFACE/PENDANT MOUNT FIXTURE QUAD SURGE PROTECTED OUTLET �z TELEPHONE OUTLET WALL Q <br /> EXACT DIMENSIONS. 24, PART 6 MANDATORY MEASURES. PULLED WITH ALL BRANCH EQUIPMENT AND FEEDER CIRCUITS. AL ALUMINUM <br /> C. INSTALLATION OF FIRE ALARM SHALL COMPLY WITH CEC,NFPA 72 AND ALL OTHER APPLICABLE E. ROUTE INDICATED LIGHTING CONTROL'ZONES'BOTH INTERIOR AND EXTERIOR THROUGH WALL MOUNT FLUORESCENT FIXTURE SURGE PROTECTED OUTLET ® TELEPHONE OUTLET IN FLOOR RED INC ARCHITECTS <br /> D. CIRCUITING: ALL WIRING SHALL BE IN CONDUIT,CONCEALED IN WALLS,ABOVE BLG BELOW GRADE � 1217J STREET,MODESTO,CA 95354 <br /> CODES AS ADOPTED AND REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. LIGHTING CONTROL PANEL'LCP'. CEILINGS,OR BELOW FLOORS, EXCEPT WHERE NOTED. IF CONCEALED RACEWAYS n 209.522.8900 <br /> D. FIRE ALARM WIRING DEPICTED ON THESE DRAWINGS IS SCHEMATIC-ACTUAL WIRE LOCATIONS F. POSITION OCCUPANCY SENSORS IN ACCORDANCE WITH MANUFACTURER'S BOD BOTTOM OF DEVICE X GFCI OUTLET ® TELEPHONE OUTLET IN CEILING <br /> ARE NOT POSSIBLE AND SURFACE RACEWAYS ARE REQUIRED, IT SHALL BE � � � UNDER CABINET LIGHTING <br /> MAY DIFFER. WIRING SHALL BE INSTALLED AS ACTUAL CONSTRUCTION ALLOW AND TO MINIMIZE RECOMMENDATIONS SO AS TO HAVE THE BEST VIEW OF ENTIRE COVERAGE AREA WHILE C CONDUIT <br /> APPROVED BY AND COORDINATED WITH ARCHITECT/ENGINEER PRIOR TO � SPLIT WIRED(SWITCHED)OUTLET � DATA/TELEPHONE OUTLET SEAL: <br /> PENETRATIONS THROUGH AREA SEPARATION&FIRE WALLS. MINIMIZING THE POSSIBILITY OF FALSE ALARMS. COMMENCING WITH ANY WORK. EMT WITH STEEL FITTINGS MAY BE USED IN DRY COD CENTER OF DEVICE <br /> } E. FIRE ALARM DEVICE BOXES IN FIRE-RATED ASSEMBLIES AND SOUND CRITICAL ASSEMBLIES(SEE G. FOR OCCUPANCY SENSORS, PROVIDE BACK BOX OF SUFFICIENT SIZE TO INSTALL PROTECTED INTERIOR LOCATIONS. PVC SCHEDULE 40 SHALL BE USED BELOW CU COPPER �0� SURFACE/PENDANT MOUNT FIXTURE <br /> ARCH DRAWINGS FOR LOCATIONS)SHALL BE INSTALLED SUCH THAT THE ASSEMBLY RATING IS ASSOCIATED POWERPACK WHERE REQUIRED. PROVIDE SEPARATIONS OF CLASS 1 AND GRADE AT MINIMUM-24 INCHES. WRAPPED RIGID ELBOWS AND RISERS SHALL BE EC ELECTRICAL CONTRACTOR SIMPLEX OUTLET ® DATA/TELEPHONE OUTLET IN FLOOR <br /> NOT REDUCED OR STC RATING IS NOT COMPROMISED. ALL BACK BOXES SHALL BE STEEL. ALL CLASS 2 WIRING PER CEC. COORDINATE WITH MANUFACTURER'S LITERATURE FOR LINE AND USED FOR ALL THROUGH-GRADE TRANSITIONS AND STUB-UPS. GRC OR IMC CONDUIT @RECESSED CEILING FIXTURE <br /> CONDUIT PENETRATIONS THROUGH,AND DEVICE BOXES INSTALLED IN RATED ASSEMBLIES LOW VOLTAGE WIRING AT ALL LIGHTING CONTROL DEVICES. TYPICAL LIGHTING CONTROL GC GENERAL CONTRACTOR ® 208V FLOOR OUTLET SO SPEAKER OUTLET <br /> WITH THREADED FITTINGS SHALL BE USED IN ALL LOCATIONS WHERE EXPOSED TO <br /> SHALL BE SEALED COMPLETELY WITH FIRE CAULK, PUTTY PADS, OR OTHER LISTED MEANS AS DETAIL. GEC GROUNDING ELECTRODE CONDUCTOR h0 WALL MOUNT FIXTURE eR sioNq <br /> THE ELEMENTS OR SUBJECT TO PHYSICAL DAMAGE. THE USE OF NM CABLE(ROMEX) DUPLEX FLOOR OUTLET S SPEAKER OUTLET WALL MOUNT OPN F <br /> REQUIRED TO MAINTAIN RATING. H. OCCUPANCY SENSORS SHALL BE MANUAL ON UNLESS NOTED OTHERWISE. IS SUBJECT TO JURISDICTION APPROVAL. EC IS RESPONSIBLE FOR COORDINATING GES GROUNDING ELECTRODE SYSTEM ® Q oQ. O 2c <br /> F. POWER FOR FIRE ALARM PANEL AND ANY FIRE ALARM POWER SUPPLIES SHALL BE PROVIDED BY I. POSITION EMERGENCY LIGHTING FIXTURES TO ENSURE THAT 1-FOOT CANDLE IS o <br /> A DEDICATED 120VAC BRANCH CIRCUIT AND IDENTIFIED IN THE SERVING PANEL AS SUCH. APPROVAL WITH AHJ.WHERE APPROVED,NM CABLE IS TO BE INSTALLED PER CEC GFCI GROUND FAULT CIRCUIT INTERRUPTER O) DIRECTIONAL CEILING FIXTURE ti <br /> MAINTAINED ALONG ALL MEANS OF EGRESS PATHS. ® DOUBLE DUPLEX FLOOR OUTLET MICROPHONE OUTLET m <br /> �3 334. ENT IS NOT ALLOWED FOR LINE VOLTAGE CIRCUITING, MOTORIZED AND VIBRATING EQUIPMENT WITH STEEL.CONNECT RECESSED AND GMC MECHANICAL CONTRACTOR ND GROUND Cr No. E 21841 <br /> cn G. POWER-LIMITED AND NONPOWER-LIMITED CIRCUIT WIRING SHALL REMAIN SEPARATED BY AT J. EXITS SHALL BE ILLUMINATED AT ANY TIME THE BUILDING IS OCCUPIED WITH LIGHT HAVING SUSPENDED LIGHT FIXTURESOO DIRECTIONAL GROUND FIXTURE <br /> LEAST 0.25"IN ALL FIRE ALARM CABINETS AND ENCLOSURES. ALL POWER-LIMITED AND INTENSITY OF NOT LESS THAN 1FOOT-CANDLE AT FLOOR LEVEL. THE POWER SUPPLY FOR ® CEILING OUTLET CABLE JACK EXP:03/31/2019 <br /> FLEX. NL NIGHT LIGHT <br /> NONPOWER-LIMITED CIRCUIT WIRING MUST ENTER AND EXIT ANY ENCLOSURE THROUGH EXIT ILLUMINATION SHALL BE FROM A GROUNDED SOURCE AND CAPABLE OF 90 MINUTES OF 2 HEAD EMERGENCY FIXTURE s F �* <br /> E. WIRING: WIRE SHALL BE COPPER AND INSULATION SHALL BE THHN UNLESS 2 T <br /> � DIFFERENT KNOCKOUTS AND/OR SEPARATE CONDUITS. OPERATION WITHOUT SOURCE POWER. TYP TYPICAL ® SPECIAL CONNECTION n INTERCOM qTF OF cA��F°kn � <br /> H. WHEN UTILIZING SHIELDED CABLE,TIE SHIELDS THROUGH AND INSULATE AT EACH JUNCTION OTHERWISE INDICATED. MINIMUM SIZE SHALL BE#12. UC UNDER CABINET/UNDER COUNTER d� EMERGENCY REMOTE HEAD FIXTURE <br /> K. LOW-LEVEL EXIT SIGNS SHALL NOT BE OF THE SELF-LUMINOUS TYPE,BUT BE <br /> mBOX. INSULATE AND TAPE BACK AT END. ELECTRONICALLY POWERED AND SHALL PROVIDE NO LESS 5 FOOT-CANDLES OR 54 LUX F. EXISTING CONDITIONS: CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR _ ® FLOOR SPECIAL CONNECTION S BELL <br /> m I. ALL FIRE ALARM CABLING SHALL BE ACCEPTABLE TO THE FIRE ALARM EQUIPMENT ILLUMINATION AT THE FACE OF THE SIGN PER CFC 1100.52 AND CFC 1011.6. WITH ALL EXISTING AND PROPOSED CONDITIONS WHICH MAY AFFECT THE COURSE UG UNDERGROUND 04/15/2019 <br /> L. A PHOTOMETRIC TEST SHALL BE CONDUCTED AT OR PRIOR TO FINAL OCCUPANCY OF WORK PRIOR TO SUBMITTING A BID ON THIS PROJECT. EXTRAS WILL NOT BE UNO UNLESS NOTED OTHERWISE ® CEILING MOUNT EXIT FIXTURE <br /> MANUFACTURER FOR THE INTENDED PURPOSE. _ JD WALL SPECIAL CONNECTION BUZZER <br /> J. SMOKE DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER ALL CONSTRUCTION CLEAN-UP IS INSPECTION DURING EARLY MORNING OR EVENING HOURS WHERE AMBIENT LIGHT DOES ALLOWED FOR FAILURE TO COMPLY WITH THIS REQUIREMENT. FIELD VERIFY ALL UTW UNSHIELDED TWISTED PAIR WALL MOUNT EXIT FIXTURE <br /> ASPECTS OF ELECTRICAL SYSTEMS PRIOR TO COMMENCING WORK. DO NOT INSTALL WP WEATHERPROOF NEW PANELBOARD, FLUSH MOUNT SECURITY SYSTEM STROBE CONSULTANT: <br /> COMPLETED. NOT EXIST. <br /> K. LOCATE SMOKE DETECTORS A MINIMUM OF 3'FROM HVAC AIR DEVICES.WALL MOUNTED SMOKE ANY ELECTRICAL COMPONENTS BEFORE VERIFYING DIMENSIONS AND ROUTING WITH XFMR TRANSFORMER ' <br /> DETECTORS SHALL BE LOCATED BETWEEN 4"(MIN)AND 12"(MAX)FROM CEILING.CEILING GENERAL NOTES - POWER BUILDING CONDITIONS. ,O, LIGHT&EXHAUST FAN COMBO a NEW PANELBOARD,SURFACE MOUNT [KPI SECURITY SYSTEM KEY PAD <br /> MOUNTED SMOKE DETECTORS SHALL BE MOUNTED TO CEILINGS AND NOT ON THE BOTTOM OF A. PROVIDE DEDICATED NEUTRAL(GROUNDED)CONDUCTOR FOR ALL BRANCH CIRCUITS. NO G. PERMITS: EC SHALL BE RESPONSIBLE FOR APPLYING FOR,OBTAINING,AND PAYING <br /> BEAMS OR JOISTS. MULTI-WIRE BRANCH CIRCUITS ARE ALLOWED. DO NOT INSTALL MORE THAN THREE(3) ALL FEES FOR ALL REQUIRED PERMITS(BUILDING PERMITS,WORK PERMITS, ETC.) ELECTRICAL DESIGNATIONS NEW POWER DISTRIBUTION SWITCHBOARD MD SECURITY SYSTEM MOTION DETECTOR <br /> L. PROVIDE CARBON MONOXIDE(CO)DETECTORS W/INTEGRATED SOUNDER IN ALL ROOMS WHERE BRANCH CIRCUITS/HOMERUNS PER RACEWAY. AND INSPECTIONS,ASSOCIATED WITH THE ELECTRICAL SYSTEMS, REQUIRED FOR CEILING FAN <br /> FUEL-BURNING EQUIPMENT,APPLIANCES,OR FIREPLACES ARE LOCATED. ALSO PROVIDE A CO B. ALL EQUIPMENT FASTENED IN PLACE OR CONNECTED BY PERMANENT WIRING METHODS THIS PROJECT. ® KEYED NOTE EXISTING PANELBOARD, FLUSH MOUNT CR CARD READER <br /> DETECTOR OUTSIDE ROOMS CONTAINING FUEL-BURNING EQUIPMENT. CO DETECTORS ARE TO SHALL BE GROUNDED. H. UTILITY SERVICE: PROVIDE POWER AND COMMUNICATIONS SYSTEM SERVICES IN 1/E5.2 INDICATES VIEW 1 ON SHEET E5.2 <br /> BE MONITORED BY THE FIRE ALARM SYSTEM. CO DETECTORS ARE TO BE INSTALLED AS C. ELECTRICAL OUTLET BOXES INSTALLED IN RATED ASSEMBLIES(SEE ARCHITECTURAL ACCORDANCE WITH THE REQUIREMENTS OF THE SERVICING UTILITIES. PROVIDE a a,b,c etc SWITCH DESIGNATION EXISTING PANELBOARD,SURFACE MOUNT <br /> z SPECIFIED BY THE MANUFACTURER, NFPA 720 AND LOCAL REQUIREMENTS. COORDINATE ALL DRAWINGS FOR LOCATIONS OF RATED ASSEMBLIES)SHALL BE INSTALLED SUCH THAT THE EXCAVATION, RACEWAY STRUCTURES,GROUNDING, ETC.AS DIRECTED, IN CEILING FAN WITH LIGHT KIT FIRE ALARM SYMBOLS <br /> I- RATING ASSEMBLY IS NOT REDUCED. ALL BOXES SHALL BE STEEL OR LISTED FOR USE IN ENGINEERING SYSTEM SOLUTIONS <br /> �_ FUEL-BURNING EQUIPMENT LOCATIONS W/MC. COORDINATE ALL CO DETECTOR LOCATIONS W/ ACCORDANCE WITH UTILITY STANDARDS. CONTACT SERVING UTILITIES AND OBTAIN JQ FLOOR MOUNT J-BOX STRUCTURAL•MEP•BUILDING COMMISSIONING <br /> AHJ AND OWNER REQUIREMENTS. RATED ASSEMBLIES AND SEALED COMPLETELY. DO NOT INSTALL ELECTRICAL DEVICE THEIR REQUIREMENTS PRIOR TO BID. (UTILITY SERVICE AND LINE EXTENSIONS CIRCUITING FRA-C-P-1 FIRE ALARM CONTROL PANEL BUILDING RELATIONSHIPS <br /> M. PROVIDE SYNCHRONIZATION OF VISUAL NOTIFICATION APPLIANCES. PROVIDE ALL REQUIRED BOXES BACK-TO-BACK IN THE SAME STUD CAVITY IN FIRE RATED WALLS OR SHALL BE CHARGES PAID BY OTHERS.) JO FLUSH MOUNT J-BOX EXCEEDING EXPECTATIONS <br /> SEPARATED BY FIRE BLOCKING OR OTHER APPROVED MEANS I.E. PUTTY PADS). ALL �� POLE MOUNT FIXTURE <br /> SYNC MODULES. PROVIDE AMULTI-SYNC MODE SLAVE CONNECTION BETWEEN ALL REQUIRED ( ) I. TEMPORARY CONSTRUCTION POWER: PROVIDE TEMPORARY ELECTRICAL POWER HOME RUN TO PANEL.NUMBER OF ARROWS FF-AP-S-1 FIRE ALARM POWER SYSTEM www.eszeng.com <br /> SYNC MODULES. CONDUIT PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED COMPLETELY AND LIGHTING FOR ALL TRADES THAT REQUIRE SERVICE DURING THE COURSE OF INDICATES NUMBER OF CIRCUITS. f JQ WALL MOUNT J-BOX 4943 NORTH 29M EAST,STEA <br /> N. VERIFY ALL FIELD SELECTABLE AUDIBILITY SETTINGS OF NOTIFICATION APPLIANCES W/FIRE WITH FIRE CAULK. EC SHALL BE RESPONSIBLE FOR ANY FIRE BLOCKING, FIRE CAULKING 0 LIGHT BOLLARD IDAHO FALLS,IDAHO 83401 <br /> AND SEALING REQUIRED SO AS NOT TO COMPROMISE RATING OF WALL ASSEMBLY.SEE THIS PROJECT. PROVIDE TEMPORARY SERVICE AND DISTRIBUTION AS REQUIRED. FARA FIRE ALARM REMOTE ANNUNCIATOR PHONE:I208I 552-9874 <br /> ALARM CONTRACTOR. BN1L-2,4,6 CIRCUIT DESIGNATION, PANEL BOARD BN1L,CIRCUITS 2,4,6 <br /> COMPLY WITH THE CEC AND OSHA REQUIREMENTS. (ENERGY COSTS BY GENERAL TO THERMOSTAT <br /> 0. UPON COMPLETION OF FIRE ALARM SYSTEM INSTALLATION AND PROGRAMMING,THE DETAIL 5/E5.2. PROVIDE COMPLIANCE WITH CHAPTER 7 OF CBC. PC PHOTOCELL JOB NUMBER: <br /> D. LOCATIONS OF RECEPTACLES ARE PARTIALLY DIAGRAMMATIC. INSTALL RECEPTACLES IN CONTRACTOR.) �� CONDUIT OR CABLING CONCEALED IN CEILING OR WALL FF-SD] FIRE/SMOKE DAMPER 17.1019 <br /> INSTALLING CONTRACTOR SHALL PERFORM FINAL TESTING OF THE ENTIRE SYSTEM, PER ALL TQ TRANSFORMER <br /> J. FUSES AND CIRCUIT BREAKERS: FUSES AND CIRCUIT BREAKERS SHALL BE SIZED 7,«a MS "tRtstR to R �.oHtr ttR ,r,rt 5 7 s <br /> APPLICABLE CODES,AND SHALL COORDINATE AND PERFORM A FINAL FIRE ALARM SYSTEM ACCORDANCE WITH PART 3 OF CEC ARTICLE 210 AS WELL AS ALL STATE AND LOCAL ="" CONDUIT OR CABLING CONCEALED UNDER FLOOR OR UNDERGROUND PC WALL MOUNT PHOTOCELL ❑F FIRE ALARM PULL STATION <br /> INSPECTION. CODES. FINAL OUTLET LOCATIONS MUST BE COORDINATED WITH DESIGN STANDARDS. PER ACTUAL NAME PLATE OF EQUIPMENT SERVED. FUSES SHALL BE DUAL-ELEMENT, Q <br /> CURRENT LIMITING AND SHALL BE INTERCHANGEABLE BETWEEN FRAME SIZES WITH - LOW VOLTAGE CABLING PS PHOTO SENSOR EM DRY TRANSFORMER <br /> E. DIMENSIONS OF ELECTRICAL GEAR AND ELECTRICAL ROOM LAYOUTS ARE PARTIALLY <br /> P. PROVIDE OFF-SITE MONITORING AS REQUIRED BY ADOPTED FIRE CODE,SECTION 907.15 AND /�� ��\ ❑M MAGNETIC DOOR HOLDER <br /> THE LOCAL AUTHORITY HAVING JURISDICTION. <br /> DIAGRAMMATIC AND ARE ESTIMATED FROM MANUFACTURER'S LITERATURE. EC SHALL STANDARD FACTORY FUSE REDUCERS. PAD MOUNT TRANSFORMER <br /> i OS <br /> Q. INSTALLING CONTRACTOR SHALL PHYSICALLY LABEL ALL INITIATING DEVICES AND NOTIFICATION COORDINATE ROOM LAYOUT FOR ACTUAL EQUIPMENT INSTALLED AND MAINTAIN WORKING K. EQUIPMENT STANDARDS: ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND OF DAYLIGHTING ZONE OCCUPANCY SENSOR 0 TS REMOTE TEST SWITCH <br /> APPLIANCE CIRCUIT END-OF-LINE(WHEN WIRING CLASS"B"). THESE LABELS SHALL BE IN PLACE CLEARANCES IN ACCORDANCE WITH CEC,STATE,AND LOCAL CODES AND AMENDMENTS. THE HIGHEST QUALITY AVAILABLE('SPECIFICATION GRADE'). LIGHTING FIXTURES <br /> SHALL HAVE ACRYLIC LENSES AND CLASS'P'BALLASTS WITH A BALLAST FACTOR OF �I- CIRCUIT,NUMBER OF HASH MARKS INDICATES NUMBER OF O g METER(PLAN VIEW) <br /> PRIOR TO START-UP AND TESTING. ALL SWITCHES,CIRCUIT BREAKERS, FUSES, ETC. SHALL BE READILY ACCESSIBLE. P POWER PACK SD DUCT SMOKE DETECTOR <br /> R. ALL FIRE ALARM WIRING THAT IS SUBJECT TO PHYSICAL DAMAGE SHALL BE INSTALLED IN F. REFER TO ARCHITECTURAL DRAWINGS, DETAILS,AND ELEVATIONS FOR FINAL LOCATIONS, 1.1 OR HIGHER. SERVICE EQUIPMENT SHALL BE FACTORY-ASSEMBLED COMMERCIAL CONDUCTORS IN CABLE/RACEWAY. GROUND WIRE NOT SHOWN <br /> CONDUIT,3/4"MINIMUM SIZE. FIRE WARNING SYSTEM CONDUCTORS SHALL BE INSTALLED IN MOUNTING HEIGHTS,AND FINISHES REQUIRED FOR ELECTRICAL DEVICES PRIOR TO GRADE,CONFIGURED PER SERVING UTILITY STANDARDS. WIRING DEVICES SHALL BE BUT SHALL BE INCLUDED. NO HASH MARKS INDICATES 2 WALL SWITCH v_F_D1 VARIABLE FREQUENCY DRIVE Fcc4field METAL RACEWAYS UNLESS SPECIFICALLY APPROVED FOR EXPOSED INSTALLATION. FIRE ALARM ROUGH-IN. SPECIFICATION GRADE WITH NYLON PLATES, IVORY UNLESS NOTED. RAISED STEEL CONDUCTORS PLUS GROUND. l FIRE ALARM BELL <br /> BOX COVERS MAY BE USED IN UTILITY AREAS. PP <br /> CONDUITS,J-BOXES, ETC SHALL BE DEDICATED TO ONLY FIRE ALARM SYSTEM WIRING AND G. PROVIDE GFCI DEVICES FOR ALL 120VAC, 15 AND 20A RECEPTACLES LOCATED OUTDOORS, 3 THREE WAY <br /> INTERIOR BOX MOUNTING HEIGHTS 4 FOUR WAY POWER POLE It FIRE ALARM HORN <br /> SHALL BE IDENTIFIED AS SUCH IN RED. FOR FIRE ALARM DEVICES, PROVIDE"5 SQUARE"DEEP IN BREAKROOMS, BATHROOMS, KITCHENS, FOOD PREP AREAS, INDOOR WET LOCATIONS, L. GUARANTEE: INSTALL ALL ELECTRICAL EQUIPMENT, LIGHTING, DEVICES, ETC. PER K KEY OPERATED El PUSH BUTTON ,�, INN & SUITES <br /> BOX(RANDL INDUSTRIES#A-55056, IN RED OR EQUAL)W/MUDRING AS REQUIRED FOR SPECIFIC OR WITHIN 6 OF ANY SINK IN ACCORDANCE WITH CEC 210.8(8). ALL GFCI DEVICES SHALL MANUFACTURERS RECOMMENDATIONS. PROVIDE ONE YEAR PARTS AND LABOR FINISHED CEILING P PILOT LIGHT LOJ FIRE ALARM HORN/STROBE <br /> DEVICE. POWER LIMITED FIRE ALARM CIRCUIT CONDUCTORS OR CABLES SHALL RUN BE SELF-TESTING TYPE, HUBBELL#GFR5362SG OR EQUAL. PROVIDE GFCI PROTECTED WARRANTY ON ALL ELECTRICAL INSTALLATION. THE COMPLETE ELECTRICAL WP WEATHERPROOF ^ <br /> SEPARATELY FROM ANY OTHER CIRCUIT OTHER THAN CLASS 2 OR 3 CIRCUITS. CIRUCUIT BREAKERS FOR ALL CIRCUITS SERVING RECEPTACLES THAT ARE INACCESSIBLE. SYSTEM,AND ALL PORTIONS,THEREOF,SHALL BE GUARANTEED TO BE FREE FROM a OS OCCUPANCY SENSOR � EMERGENCY BUTTON BY MARRIOTT <br /> S. ALL ELECTRICAL,ALARM,TELECOM, COMPUTER, ETC.WIRING WITHIN RETURN AIR(R/A)PLENUMS H. REFER TO EQUIPMENT CONNECTION SCHEDULE ON E6 SERIES SHEETS FOR ELECTRICAL DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROMD DIMMER B FIRE ALARM STROBE <br /> AND OTHER AIR HANDLING SPACES SHALL BE RATED FOR USE IN PLENUMS PER 2013 CMC CONNECTIONS,CIRCUITING, DISCONNECTS AND CONTROLS REQUIRED FOR HVAC AND FINAL ACCEPTANCE. PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT p MC SPDT-MOMENTARY CONTACT COMBO STARTER <br /> SECTION 602.2 EX:5 AND 2013 CEC ART.300.22. PLUMBING EQUIPMENT. DAMAGE CAUSED BY THE DEFECTS OR REPAIR THEREOF AT NO EXPENSE TO THE BOD LV LOW VOLTAGE SD SMOKE DETECTOR <br /> T. REFER TO PANEL SCHEDULES FOR CIRCUITING TO 120VAC FIRE SMOKE DAMPERS. WIRING FOR I. ROUTE ALL CONDUIT(S)FOR ROOF-MOUNTED EQUIPMENT INSIDE EQUIPMENT CURB BASE OWNER. LAMPS ARE EXEMPT FROM THIS GUARANTEE, BUT SHALL BE NEW AND a T TIMER ® CONTACTOR <br /> CIRCUIT MAY NOT BE SHOWN, PROVIDE ALL CONDUIT(3/4"EMT)AND CONDUCTORS REQUIRED TO AVOID ADDITIONAL ROOF PENETRATIONS. COORDINATE EXACT LOCATION AND UNUSED AT THE TIME OF ACCEPTANCE. TOD TS TOUCH SCREEN SD SMOKE DETECTOR WALL MOUNT <br /> TO CONNECT ALL FIRE SMOKE DAMPERS. PLACEMENT OF CONDUIT(S)INSIDE EQUIPMENT CURB BASE WITH MC PRIOR TO ROUGH-IN M. SUBMITTALS: SUBMIT FACTORY SHOP DRAWINGS FOR ALL LIGHTING FIXTURES, T z �' DISCONNECT SWITCH <br /> #B CONTROL STATION <br /> FOR ACTUAL EQUIPMENT INSTALLED. COD " J CO CARBON MONOXIDE DETECTOR <br /> U. REFER TO PANEL SCHEDULES FOR CIRCUITING TO 120VAC MAGNETIC DOOR HOLDERS. WIRING SWITCH GEAR, PANELS, MOTOR CONTROL,WIRING DEVICES, ETC. PROPOSED FOR o w w w #FOR BUTTON COUNT <br /> FOR CIRCUIT MAY NOT BE SHOWN. FOR ALL MAGNETIC DOOR HOLDERS PROVIDE 4-SQ BACK J. SEE ALSO PANEL SCHEDULES FOR MORE INFORMATION REGARDING BRANCH CIRCUITS. THIS PROJECT. PROPOSED SUBSTITUTIONS SHALL BE EQUAL OR SUPERIOR TO $v o 2E U 0 � ® CIRCUIT BREAKER <br /> BOX W/SINGLE-GANG MUDRING FOR FLUSH-MOUNTED ELECTROMAGNETIC DOOR HOLDER. FOR K. WHERE RECEPTACLES AND TELECOM OUTLETS ARE ADJACENT TO EACH OTHER, INSTALL SPECIFIED ITEMS IN ALL RESPECTS. DETERMINATION OF EQUALITY RESTS SOLELY COD o o ,�,, HD HEAT DETECTOR <br /> SYSTEM CONNECTED HOLDERS, PROVIDE 1/2"C W/FIRE ALARM WIRING-(2)#14-FOR 24VAC/VDC ON OPPOSITE SIDES OF THE SAME STUD/FRAMING MEMBER OR WITHIN THE SAME STUD WITH THE ENGINEER. ALL PROPOSED SUBSTITUTIONS SHALL BE RECEIVED BY THE HC E m p w o HATCHING INDICATES EMERGENCY/ ® FUSE <br /> CAVITY ON A COMMON MOUNTING BRACKET. ERICO'CADDY'#RBS OR EQUAL,SUCH AS COD o m m o w BATTERY FIXTURE(TYPICAL FOR ALL Q <br /> CONNECTION TO FIRE ALARM SYSTEM. LOCATE MAGNET ON WALL BEHIND DOOR PER ENGINEER 10 DAYS PRIOR TO BID. w o = <br /> MANUFACTURER'S RECOMMENDATIONS -2'-4'AFF&-6"FROM LOCK STILE AT DOOR AND THAT ALL ADJACENT DEVICES ARE SPACED THE SAME THROUGHOUT THE BUILDING. AC=ABOVE COUNTER, O ~ � p w FIXTURES&SYMBOLS) DS DOOR SWITCH HD HEAT DETECTOR WALL MOUNT Z <br /> ( ) N. LOCATIONS: INDICATED LOCATIONS OF ALL LIGHTING,OUTLETS, RECEPTACLES, a w = <br /> COORDINATE FINAL LOCATION W/GC. L. FOR ALL T-STAT LOCATIONS, PROVIDE BACK BOX,MUDRING,AND 1/2"C TO MINIMUM 4"ABOVE _ O ¢ o ~ 0 <br /> POWER CONNECTIONS AND EQUIPMENT ARE PARTIALLY DIAGRAMATIC AND SUBJECT w o V. ALL FIRE PROTECTION DEVICES MUST INCLUDE MINIMUM 90 MINUTE BATTERY BACKUP. CORRESPONDING UNIT WITH PULL-LINE FOR CONTROL WIRING BY M.C. COORDINATE FINAL BACKSPLASH TO LO o z o ~ = MAG MAGNETIC DOOR SWITCH <br /> LOCATION AND ORIENTATION WITH M.C. FOR ADA/ACC ROOMS ELECTRICAL MOUNTING TO CHANGE. COORDINATE FINAL LOCATIONS WITH ARCHITECTURAL DRAWINGS AND 2i O° NOT ALL TS FIRE/SPRINKLER TAMPER SWITCH <br /> W. PROVIDE 120VAC CONNECTION TO ALL FIRE SMOKE DAMPERS(SEE PANEL'1T'PANEL SCHEDULE ACTUAL FIELD CONDITIONS. SHIFT/RELOCATE/RECONFIGURE ANY OUTLET, BOTTOM OF DEVICE. o wo <br /> FOR CIRCUITING INFO). DAMPERS PROVIDED AND INSTALLED BY MC(SEE M-DRAWINGS FOR HEIGHTS SEE"ACCESSIBILITY NOTES ELECTRICAL MOUNTING HEIGHTS"NOTES ON SHEET EQUIPMENT,OR CONNECTION POINT UP TO 10 FEET AS DIRECTED BY THE ENGINEER, a 91 V7 . co `� �M MOTOR CONTROL SWITCH U <br /> EXACT LOCATIONS OF DAMPERS). PROVIDE 120VAC CONNECTION TO ALL DUCT SMOKE EO.1. AT NO ADDED COST. INSTALL RECEPTACLES IN ACCORDANCE WITH PART III OF CEC COD SYMBOLS MAY BE FS FLOW SWITCH <br /> DETECTOR(S)TO OPERATE ASSOCIATED FIRE SMOKE DAMPER(S). LOCATE DETECTOR WITHIN 5' M. ALL EXTERIOR RECEPTACLES ARE TO BE GFCI PROTECTED AND EQUIPPED WITH AN ARTICLE 210 AS WELL AS ALL STATE AND LOCAL CODES. `0, MOTOR CONNECT <br /> OF A DAMPER. COORDINATE W/MC FOR INSTALLATION OF SAMPLING TUBE IN DUCTWORK. APPROVED WEATHERPROOF IN-USE COVER IN ACCORDANCE W/CEC 406.9. 0. IDENTIFICATION: IDENTIFY ALL EQUIPMENT,SWITCHBOARD CIRCUITS,AND USED PS FIRE/SPRINKLER PRESSURE SWITCH <br /> INSTALL DETECTOR WITHIN 5'OF DAMPER. PROVIDE RELAY MODULE(S)FOR HVAC UNIT SHUT- ELECTRICALLY-CONNECTED EQUIPMENT WITH ENGRAVED NAMEPLATES. PANEL FINISHED FLOOR <br /> DOWN UPON DETECTION OF SMOKE IN DUCTWORK. PROVIDE ALL CONDUIT AND REQUIRED FIRE ELECTRICAL POWER DISTRIBUTION DIRECTORIES SHALL BE TYPED. <br /> ALARM WIRING TO'FACP'FOR COMPLETE CONNECTION. <br /> A. ELECTRICAL POWER DISTRIBUTION THROUGH ELECTRICAL PANEL BOARDS IS DESIGNED TO P. PANEL BOARDS: PANEL BOARDS SHALL HAVE LOCKING COVERS. ELECTRICAL SHEET INDEX <br /> MEET 2013 CALIFORNIA TITLE 24 ENERGY CODE SECTION 130.5. DISAGGREGATION OF Q. COORDINATION:CLOSELY COORDINATE ALL ELECTRICAL SYSTEMS WITH ACCESSIBILITY NOTES - ELECTRICAL <br /> ELECTRICAL LOADS IS DESIGNED TO MEET TABLE 130.5-B. MECHANICAL, PLUMBING,STRUCTURAL,AND ARCHITECTURAL SYSTEMS. SHEET NO. SHEET TITLE REVISION <br /> CONDUIT/CABLE ROUTING IS APPROXIMATE AND DIAGRAMMATIC AND SHALL NOT BE MOUNTING HEIGHTS EO.1 GENERAL NOTES,SHEET INDEX,ABBREVIATIONS AND SYMBOLS 1 <br /> SCALED. PROVIDE ALTERNATE ROUTING FOR COORDINATION OF ALL WORK WITHOUT A. THE CENTER OF THE OPERATING HANDLE OF DEVICES USED TO CONTROL E1.0 ELECTRICAL SITE PLAN 2 <br /> GENERAL NOTES - TELECOMMUNICATIONS ADDITIONAL COST TO OWNER.COORDINATE WITH MECHANICAL DUCT WORK AND LIGHTING,T-STATS,OR OTHER ENVIRONMENTAL CONTROL DEVICES SHALL E1.OA ELECTRICAL PHOTOMETRIC SITE PLAN <br /> A. WHERE RECEPTACLES AND TELECOM OUTLETS ARE ADJACENT TO EACH OTHER, INSTALL STRUCTURAL MEMBERS FOR BEST LOCATION OF FIXTURES TO PROVIDE MAXIMUM BE LOCATED NO HIGHER THAN 48"AND NO LOWER THAN 15"AFF. E1.1 ELECTRICAL LIGHTING PLAN-LEVEL 1 4 <br /> "B. IF REACH IS OVER AN OBSTRUCTION (I.E.,BASE CABINET)BETWEEN 20 <br /> ON OPPOSITE SIDES OF THE SAME STUD/FRAMING MEMBER OR WITHIN THE SAME STUD UNOBSTRUCTED LIGHTING. E1.2 ELECTRICAL LIGHTING PLAN-LEVEL 2 4 <br /> CAVITY ON A COMMON MOUNTING BRACKET. ERICO'CADDY'#RBS OR EQUAL,SUCH THAT R. ELECTRICAL CONNECTIONS:COORDINATE ALL POWER AND CONTROL 25"DEEP,THE MAX MOUNTING HEIGHT IS REDUCED TO 44"(FOR FORWARD E1.3 ELECTRICAL LIGHTING PLAN-LEVEL 3 4 <br /> ALL ADJACENT DEVICES ARE SPACED THE SAME THROUGHOUT THE BUILDING. REQUIREMENTS OF SYSTEMS PROVIDED BY OTHERS(HVAC EQUIPMENT, KITCHEN APPROACH)OR 46"(FOR SIDE APPROACH)AFF. OBSTRUCTION MAY NOT <br /> B. REFER TO ARCHITECTURAL DRAWINGS, DETAILS AND ELEVATIONS FOR FINAL LOCATIONS, EQUIPMENT, ETC.). E.C.SHALL BE RESPONSIBLE FOR ALL LINE VOLTAGE EXTEND MORE THAN 25"FROM THE WALL BENEATH THE CONTROL DEVICE E2.1 ELECTRICAL POWER&SPECIAL SYSTEMS PLAN-LEVEL 1 <br /> MOUNTING HEIGHTS AND WALL FINISHES REQUIRED FOR ALL ELECTRICAL DEVICES PRIOR CONNECTIONS. C. THE CENTER OF AN ELECTRICAL OUTLET, RATED 30A OR LESS,SHALL BE E2.2 ELECTRICAL POWER&SPECIAL SYSTEMS PLAN-LEVEL 2 2 <br /> TO ROUGH-IN. COORDINATE FINAL LOCATIONS OF ALL ELECTRICAL DEVICES INSTALLED S. PENETRATIONS:COORDINATE WORK IN EXTERIOR WALLS TO MINIMIZE INTERRUPTION INSTALLED NO HIGHER THAN 48"AND NO LOWER THAN 15"AFF. IF REACH E2.3 ELECTRICAL POWER&SPECIAL SYSTEMS PLAN-LEVEL 3 2 <br /> WITHIN CABINETS OR MILLWORK WITH GC. OF INFILTRATIONNAPOR BARRIER SEAL AROUND ALL PENETRATIONS. IS OVER AN OBSTRUCTION,COMPLY WITH REQUIREMENT B AS WELL. E2.4 ELECTRICAL ROOF PLAN 2 <br /> C. ALL TELECOM PATHWAYS(CONDUITS AND J-HOOKS)SHALL BE CONCEALED OR ROUTED T. CLEARANCES: PROVIDE MINIMUM WORKING CLEARANCES PER CEC. D. THE CENTER OF A FIRE ALARM INITIATING DEVICE(I.E. PULL STATION) <br /> SHALL BE LOCATED 48"AFF(FLOOR, PLATFORM,GROUND,OR SIDEWALK). E4.1 ENLARGED ELECTRICAL PLANS 2 <br /> ABOVE ACCESSIBLE CEILINGS AND SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE U. LINE/LOW VOLTAGE WIRING:MAINTAIN 18"(MINIMUM)CLEARANCE BETWEEN LINE E4.2 ENLARGED ELECTRICAL PLANS 2 <br /> MANNER. ROUTING SHALL BE STRAIGHT AND SQUARE WITH BUILDING CONSTRUCTION AND VOLTAGE CIRCUITING AND ALL LOW VOLTAGE,SIGNAL BUS,TELEPHONE,DATA, E5.1 ELECTRICAL DETAILS 1 <br /> SHALL BE AT CONSISTENT ELEVATIONS. TELEVISION,SATELLITE, ETC.CABLING. INTERSECTIONS BETWEEN LINE VOLTAGE E5.2 ELECTRICAL DETAILS 2 <br /> D. COORDINATE FINAL LOCATION, ELEVATION AND ROUTING OF TELECOM PATHWAYS ABOVE CIRCUITS AND LOW VOLTAGE CABLE SHALL BE AT 90 DEGREE ANGLES. <br /> ACCESSIBLE CEILINGS WITH LIGHTING, DUCTWORK, PIPING, CONDUITS, ETC. FOR TELECOM V. SUPPORTS: E.C.SHALL BE RESPONSIBLE FOR ALL CONCRETE PADS,SUPPORTS, E5.3 ELECTRICAL DETAILS 0 <br /> PATHWAYS ABOVE ACCESSIBLE CEILINGS, PROVIDE 2"J-HOOKS W/RETAINER CLIP BASES, ETC.THAT ARE REQUIRED FOR ELECTRICAL EQUIPMENT. E6.1 ELECTRICAL SCHEDULES 2 <br /> FASTENED TO WALL OR SELF-SUPPORTING ALL THREAD AT AN ALTERNATING 4'&5'O.C. W SEISMIC RESTRAINTS: PROVIDE SEISMIC RESTRAINTS FOR REQUIRED ELECTRICAL E6.2 ELECTRICAL SCHEDULES 2 <br /> U� SPACING(TO AVOID CABLE HARMONICS). J-HOOK PATHS SHALL BE STRAIGHT AND SQUARE <br /> WITH CEILINGS(NO DIAGONAL)WITH(25)MAX CABLE COUNT. PROVIDE A MINIMUM OF TWO EQUIPMENT, RACEWAYS,LIGHT FIXTURES, ETC. IN ACCORDANCE WITH CBC. E6.3 ELECTRICAL SCHEDULES 2 Z <br /> (2)VELCRO TIES(NO CABLE TIES)ON CABLE BUNDLES BETWEEN EVERY J HOOK. X. FIRE SAFING: PROVIDE ELECTRICAL CONNECTIONS TO FIRE AND FIRE/SMOKE E6.4 ELECTRICAL SCHEDULES <br /> E. FOR EACH COMBINATION TELEPHONE/DATA LOCATION, PROVIDE 5"SQ,2-1/8"DEEP DAMPERS WHERE REQUIRED. PROVIDE FIRE SAFING(FIRE CAULK, PUTTY PADS, ETC.) E6.5 ELECTRICAL SCHEDULES <br /> BACKBOX W/SINGLE-GANG MUDRING AND(1) 1"C(EMT OR FMC)WITH PULL STRING ON ALL PENETRATIONS IN AND THROUGH FIRE RATED SEPARATIONS WITH UL LISTED E7.1 ELECTRICAL ENERGY CODE COMPLIANCE O <br /> STUBBED UP TO ABOVE NEAREST ACCESSIBLE CEILING FOR TELECOM CABLING. ALL FIRE SAFING MATERIAL. U <br /> E7.2 ELECTRICAL ENERGY CODE COMPLIANCE <br /> TELECOM OUTLETS SHALL HAVE CABLING ROUTED CONTINUOUS TO PBX ROOM OR Y. COORDINATE LOCATION OF CONDUITS THROUGH FLOOR FRAMING WITH OTHER <br /> E7.3 ELECTRICAL ENERGY CODE COMPLIANCE <br /> INTERMEDIATE HUB/IDF ON EACH FLOORS ELECTRICAL ROOM. SEE DETAIL 4/E5.2. TRADES(FIRE SPRINKLER, HVAC, PLUMBING, ETC.)FOR NEAREST AND MOST DIRECT � <br /> ROUTING. U) p <br /> Z. BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3%AT O OJ <br /> FARTHEST OUTLET. <br /> AA. COMBINE HOME RUNS FOR BRANCH CIRCUITS IN COMMON CONDUIT RUNS WHERE <br /> POSSIBLE,AND IN ACCORDANCE WITH ALLOWABLE CONDUCTOR FILL <br /> REQUIREMENTS. <br /> 53 REVISIONS: <br /> 1 BLDG DEPT 10/12/18 <br /> u <br /> m <br /> -m <br /> m <br /> m BA PROJECT# 161010 <br /> PLN PROJECT# 17077 <br /> MARRIOTT# 4476 <br /> Fm <br /> U PERMIT# - <br /> APN# 058-66-012 <br /> U <br /> N <br /> r.. <br /> t <br /> Q <br /> DATE: 4/15/19 <br /> DRAWN: DW <br /> CHECKED: JC <br /> SHEET TITLE: <br /> GENERAL NOTES, <br /> SHEET INDEX, <br /> ABBREVIATIONS AND <br /> SYMBOLS <br /> 'C <br /> d <br /> SHEET NO.: <br /> c <br /> 3 <br /> c� <br /> L <br /> r <br /> E001 <br />