My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROCKY
>
262
>
1600 - Food Program
>
PR0545763
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 6:12:58 PM
Creation date
8/25/2020 2:50:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545763
PE
1624
FACILITY_ID
FA0025909
FACILITY_NAME
FAIRFIELD INN & SUITES LODI
STREET_NUMBER
262
STREET_NAME
ROCKY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
262 ROCKY LN
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
on <br /> � CV <br /> N <br /> GENERAL NOTES - LIGHTINGqv U <br /> SEE E0.1 SHEET FOR LIGHTING NOTES. • , w <br /> x KEYNOTES KEYNOTES <br /> O L11 LOCATED LIGHT FIXTURES AND PILOT SWITCH IN ELEVATOR PIT. LIGHT <br /> N <br /> U <br /> L52 FOR GUEST ROOM CORRIDOR LIGHTING CONTROL PROVIDE ULTRASONIC FIXTURES TO PLACED ABOVE ALL HOISTWAY CONTROL PANELS AND <br /> M _ ,� �� �, �, - � „ � „ � , - �� ,, 1 1 " �_ �' CEILING MOUNTED OCCUPANCY SENSOR,WATTSTOPPER#W-2000H OR EQUAL MACHINERY IN ACCORDANCE CBC 3006.2. MINIMUM LIGHT OUTPUT TO BE 19 FC <br /> IN CORRIDORS. PROVIDE POWER PACK(LEVITON#OPP20-D2 OR EQUAL)AS AT WORK SPACE. COORDINATE LOCATION AND MOUNTING W/ELEVATOR <br /> REQUIRED FOR COMPLETE CONNECTION. SEE DETAIL 3/E5.3. OCCUPANCY EQUIPMENT INSTALLER PRIOR TO ROUGH-IN <br /> �y 7 o� r� r SENSING CONTROLS SHALL REDUCE LIGHTING POWER BY AT LEAST 50%WHEN /4 RED INC ARCHITECTS <br /> 022 W DG290r 0229Ff AREA IS UNOCCUPIED.CONTROLS SHALL BE ACTIVATED FROM ALL DESIGNED 1217J STREET,MODESTO,CA 95354 <br /> BR-400b �, 00d BR400 f PATHS OF EGRESS.COORDINATE LOCATION OF OCCUPANCY SENSOR WITH GC L14 LIGHT FIXTURES ARE TO BE PENDANT MOUNTED BELOW EXPOSED DUCTWORK. 209.522.8900 <br /> 7T AFF 86n AFF 7815'AFF TO ENSURE COMPLETE COVERAGE. L31 PROVIDE LEVITON TOUCHSCREEN#SAPPHIRE AND 120V POWER SUPPLY ALONG <br /> SEAL: <br /> WITH ALL ACCESSORIES FOR COMPLETE INSTALLATION. INTERCONNECT TOUCH <br /> } y I I L53 FOR STAIRWELL LIGHTING CONTROL PROVIDE ULTRASONIC CEILING MOUNTED SCREEN WITH THE LIGHTING CONTROL PANEL'LCP'. REFER TO THE LIGHTING <br /> } OCCUPANCY SENSOR,WATTSTOPPER#W-2000H OR EQUAL. PROVIDE POWER CONTROL PANEL SCHEDULE AND LEVITON#SAPPHIRE TOUCH SCREEN <br /> + co bD PACK(LEVITON#PP20-D2 OR EQUAL)AS REQUIRED FOR COMPLETE CONTROL SCHEDULE FOR MORE INFORMATION. <br /> CONNECTION.SEE DETAIL 3/E5.3. OCCUPANCY SENSING CONTROLS SHALL S/ <br /> REDUCE LIGHTING POWER BY AT LEAST 50%WHEN AREA IS UNOCCUPIED. QR N J. <br /> L32 PROVIDE LOW VOLTAGE SWITCH LEVITON#RDGSW SERIES, FOR EVENT SOP CO F <br /> CONTROLS SHALL BE ACTIVATED FROM ALL DESIGNED PATHS OF EGRESS. O 2 <br /> CENTER LIGHTING CONTROL.COORDINATE ZONES OF CONTROL WITH <br /> COORDINATE LOCATION OF OCCUPANCY SENSOR WITH GC TO ENSURE 2 <br /> COMPLETE COVERAGE.SEE STAIRWELL LIGHTING CONTROL DETAIL 6/E5.3. ARCHITECT/OWNER.SEE LCP AND SAPPHIRE TOUCHSCREEN DETAIL FOR MORE m <br /> rti ` E 21 41 <br /> INFORMATION N Po.XP:03311.019 A <br /> D2FJ L71 EC TO FIELD VERIFY EXACT LENGTHS OF UNDER CABINET LIGHTING. PROVIDE <br /> L36 FOR ROOM/AREA LIGHTING CONTROL PROVIDE 120VAC, DUAL-TECHNOLOGY <br /> th 0229U IBR40 J02A,J02B,AND J02C FIXTURES AS NEEDED TO FILL FULL LENGTH OF UNDER WALL SWITCH OCCUPANCY SENSOR, LEVITON#OSSMT-MD. MATCH TRIM TgTF Fo�� <br /> `� BR400C Up AFF I) Gf CABINET.SEE LIGHT FIXTURE SCEDULE FOR J02 FIXTURE LENGTHS. COLOR WITH OTHER TRIM IN SAME AREA. of cA�� <br /> n <br /> m Dir 78 5.AFF BRAS 04/15/2019 <br /> IBR-400a 64-5" <br /> AFF L72 SEE GUESTROOM CIRCUITING NOTES ON E4.2 FOR GUESTROOM BRANCH CIRCUITING INFORMATION.SEE ALSO PANEL SCHEDULES. L37 FOR ARENROOM DAYLIGHT CONTROL PROVIDE LEVITON PROVOLT OCCUPANCY <br /> SENSOR#06C04-IDW. DAYLIGHT SENSOR SHALL CONTROL ALL FIXTURES <br /> rz 64,5"AFF <br /> INDICATED WITH A LOWERCASE LETTER IN THE MARKED DAYLIGHT ZONE. SEE CONSULTANT: <br /> i"Ek-ERLINE TABLE BELOW FACE OF WALL AT Tl/ L74 REFER TO COMMUNAL TABLE LIGHT FIXTURE GROUP DETAIL FOR INFORMATION MANUFACTURES CUT SHEETS FOR MORE INFORMATION. SEE DETAIL 6/E5.3 FOR <br /> REGARDING LIGHT TYPES AND HEIGHTS.COORDINATE W/OWNER OR MORE INFORMATION. <br /> ARCHITECT PRIOR TO ROUGH-IN. <br /> 1 COMMUNAL TABLE LIGHT FIXTURE GROUP FOR ROO <br /> L75 FOR Z37A RGB WATERPROOF LED EXTERIOR FIXTURES, MOUNT HORIZONTALLY. L38 06C04REWTCONTROLLEVITON PROVOLT <br /> LIGHTING CONTROLS SHALL SHUT OFF ALL LIGHTING WHEN AREIS <br /> NO SCALE <br /> FOR Z37C RGB WATERPROOF LED EXTERIOR FIXTURES, MOUNT VERTICALLY. UNOCCUPIED. SEE DETAIL 2/E5.3 FOR MORE INFORMATION. <br /> COORDINATE EXACT LOCATION AND MOUNTING DETAILS AND LENGTHS WITH <br /> ARCHITECT. SEE ARCHITECTURAL LIGHT COVE DETAIL.APPROXIMATE LENGTH <br /> OF CONTINUOUS LIGHTING FOR Z37A FIXTURE IS 24",OR(1) FIXTURE. L39 FOR ROOM/AREA LIGHTING CONTROL PROVIDE LEVITON 4-BUTTON WALL <br /> APPROXIMATE LENGTH OF CONTINUOUS LIGHTING FOR Z37C FIXTURE IS 401,OR STATION,#PLVSW-4LW.CONNECT WALL STATION TO PROVOLT OCCUPANCY ENGINEERING SYSTEM SOLUTIONS <br /> (5)FIXTURES.COORDINATE RGB CONTROL W/OWNER AND MANUFACTURER SENSOR.SEE LIGHTING CONTROL DETAIL 2/E5.3. STRUCTURAL•MEP•BUILDING COMMISSIONING <br /> DOCUMENTATION. BUILDING RELATIONSHIPS <br /> EXCEEDING EXPECTATIONS <br /> L40 PROVIDE LEVITON PHOTOCELL#ODCOP-W FOR DAYLIGHTING CONTROL. www.es2eng.com <br /> L76 SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF ALL INDIRECT, DAYLIGHT SENSOR SHALL CONTROL ALL FIXTURES INDICATED WITH A 4943 NORTH 29TH EAST,STEA <br /> LOWERCASE LETTER IN THE MARKED DAYLIGHT ZONE. INTERCONNECT IDAHO FALLS,IDAHO 83401 <br /> COVE, UNDER CABINET, ETC.AMBIENT LIGHTING. <br /> PHOTOCELL WITH THE GREENMAX LIGHTING CONTROL PANEL FOR COMPLETE PHONE: <br /> Z01 O O Z 1 INTEGRATION.SEE MANUFACTURES CUT SHEETS FOR MORE INFORMATION. JOB NUMBER: 17.1019 <br /> TFMSEPLANS,DRAWMGS AIm DESIGNS ARE THEIXCLUSNE PROPERTYOF NJO <br /> SYSTEM SOLATIONS AND SHALL NOT BE REPRODUCED MANYFORM WITHOLT WRITTEN <br /> CONSENT.ALLRbHTS ARE RESERVED.COPYRIGHT 2018 ENGMEERMG SYSTEM SOLLTIONS <br /> L45 FOR ROOM/AREA LIGHTING CONTROL PROVIDE CEILING MOUNTED OCCUPANCY <br /> Z01 QO 11 Z 1 SENSOR,LEVITON#OSCXX-RXW OR EQUAL.CONNECT SENSOR TO LEVITON <br /> #OPP20-D2 POWER PACK WITH NECESSARY LOW VOLTAGE WIRING FOR <br /> COMPLETE INSTALL.OCCUPANCY SENSING CONTROLS SHALL SHUT OFF ALL <br /> 0 0 o Z01 QO Z 1 LIGHTING WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE.FULL <br /> AUTOMATIC-ON CONTROLS SHALL NOT BE PERMITTED.INTERCONNECT <br /> PHOTOCELL WITH THE GREENMAX LIGHTING CONTROL PANEL FOR COMPLETE <br /> INTEGRATION. INSTALL OCCUPANCY SENSOR ACCORDING TO MANUFACTURERS O <br /> Z78 ® Z78 Z78 GUIDELINES TO ENSURE COMPLETE COVERAGE. <br /> � a <br /> L51 FOR PUBLIC RESTROOMS LIGHTING CONTROL,PROVIDE CEILING MOUNTED <br /> OCCUPANCY SENSOR,LEVITON#OSCXX-RXW OR EQUAL SUCH THAT IT REMAINS MH o 5 U Q 'r [E S <br /> OUT OF REACH FROM UNAUTHORIZED PERSONNEL.CONNECT SENSOR TO <br /> LEVITON#OPP20-D2 POWER PACK WITH NECESSARY LOW VOLTAGE WIRING [BY N A° rM IR 0 OO T T <br /> FOR COMPLETE INSTALL.OCCUPANCY SENSING CONTROLS SHALL SHUT OFF <br /> ALL LIGHTING WITHIN 30 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE. <br /> CONFIGURE SENSOR AND POWER PACK TO WORK IN AUTO-ON/AUTO-OFF <br /> Z78 Z78 Z78 MODE. INSTALL OCCUPANCY SENSOR ACCORDING TO MANUFACTURERS <br /> GUIDELINES TO ENSURE COMPLETE COVERAGE.SEE DETAIL 4/E5.3 FOR MORE <br /> INFORMATION. <br /> 1 <br /> TT <br /> (10 (11 11.912 (13 (14 (15 (16 (17 (18 (19 (20�Z78 z78 T T T T T T Q <br /> Z36A Z36A — — — Z16: z <br /> 1L-12 0 TIM 7.RA 7.16A 7'16A 736A <br /> " — A = — — — — — — — — — — — — — — A Q <br /> 1 I <br /> — — — — — — — — — — — — — L75 <br /> 720 72or X1 <br /> °R72 'OR72 IoA 11A° <br /> 72 0 0 72L- <br /> ° L38 ° o_ o CP- 5 <br /> L76 R72 Z71 Z71 Z71 (TI <br /> ° ° 0 X EXIT~ <br /> LCP 15 L39 L- <br /> Z 8 Z 8 01 BO J18 <br /> — T X2 <br /> p L32 X3 <br /> (TIE) LCP-26 — L71 L76 E 4 D13" X1 <br /> 6°a R86 o a —°a I L — o o a o o L36 L71 <br /> R a a PAA Daa— 86 L14 JO B 1 01 ° L31 (TY 4) o o ° 2° Z 31 <br /> — R72 R72 E <br /> ° I ° ° L39 <br /> 01 R87 - 6'. 04 — i B01 ; X3 B01 L76 ; 4 O <br /> g ° a °RBEL38 I L39 . 2 J 0 L76 - � OLA <br /> Q R L40 B01 ° B01 R 9 1 ) <br /> 0 IN P <br /> Ta< 0 6 0 o I � L38 c L76 L38� Q <br /> w L53 6 ° B01 B01 L38 ° B01 B01 ° 8 0 10 L OS 05 <br /> w 04 04 04 0 E — — O L71 L14 <br /> 0 0 0 o L71 L76 L76 J05 <br /> ° J05 <br /> 3 � <br /> — 9 L14 L72 J05 � <br /> 4 6 L36 pg L14 L36 o O <br /> 0 6 o <br /> __ J05 O L 1 1 <br /> P ° L39 — L14 27 L11 J054 — J20 J20 L76 J20 J20 J20 L TIE J05 � <br /> ULF <br /> R87 ° B04 04 04 0 cn 228 0 7 <br /> z <br /> 1 L-8 x1 3 L36 R72° o L76 1 L J L36 Q O <br /> LFL <br /> 0 0 0 0 0 0 0 o RB 3 L36 - - - - - - ° ° 0 0 o N E Imi <br /> L39 ° 6 0 <br /> (TIE) — — — — V13o — — — R86 R86 -R86 R86— — 1L=5 R72 — Ll L <br /> R72 R72 — — 0 86° D23 86 0 0 0 o L52 X X2 — F O <br /> 45 o R 6 0 �J) — R8 0 0 0 0 o ZONE'9' ® X1 L52 X Z28 � <br /> 236A <br /> w o 0 0 o X X1 — R86 __ __ __ —__— _—__ __ _ ___— _—__ __ __ __ __ UPLIGHT TO BE INSTALLED U <br /> UPLIGHT TO BE INSTALLED R o — 1L-3 0 0 0 0 0 0 0 0 0 0 0 0 0 ABOVE CANOPY <br /> ABOVE CANOPY Z28 — B04 R72° ° ° 0 0 0 0 o J21 J21 J21 J21 J21 — — <br /> R72 R72 R72 a O <br /> �G — J ° — L45 — L31 86 B04 0 — — L76 a 87 ZONE' ' R86 o D 4 0 0 — 234 0 o D23 R8 G zz O <br /> Z3 L32 R7 0 0 0 0 (TIE) L14 L36 D2 6 <br /> X3 K 1 v <br /> R86 Z °o ° L39 <br /> 0 1 Z38 <br /> -� L36 L45 L31 TS3 � o J05 JO X L747/ R87 — <br /> o R72 EXIT 3 0 0 o R8 ° 0 1L LCP 3 °R87 0 O O o 6 <br /> o ° �Iz X1 R 6 R86 B04 B04 0 6 R73 R73 ° ZON ° LCP 15 <br /> _ _ B04 04 3 0 0 0 0 0 06 25 (TIE) REVISIONS: <br /> L14 Koo 0 0 0 0 0 0 0 0 0 0 o R �° ° L14 X — — L38 L72 4 OWNER REV. 04/03/19 <br /> 4710 0 o R7 J05 _ L36 ° 7 ° <br /> e L51 <br /> 1 L-19 7// <br /> J05 R o R o 86 L39 d <br /> n— 1X o 0 0 0 <br /> (TIE) — gp — 0 i X3 o FV2— R72— BO B L53 <br /> R o 0 0 0 0 0 0 0 86 R87 L39 <br /> 0 0 R7 R87 0 0 0 o R87 ° <br /> Q <br /> 8 R86 0 <br /> C) L14 0 g IG Z _ B04 B °6 L38 1 L- R87 o R87 2 R72 <br /> m — <br /> R ° ° 0 0 0 0 ° 01 R87 K01 <br /> L36 J05mly <br /> (G'91 ° b b b b o o ° R87° X3 B06 G.9� <br /> (H 1 BO — ° SEE 3/E5.2.TYPICAL FOR <br /> C33�' (H.5� 0 b E 1 P o — 6 EXIT ° ALL LAY IN FIXTURES H.5) BA PROJECT# 161010 <br /> o 0 o o o o b b o R71 – – – R72°� PLN PROJECT# 17077 <br /> 86 R86 1 L32 b o <br /> X3LCP-3c' — — — — MARRIOTT# 4476 <br /> 1L-8 Z38 Z38 Z38B 738B B <br /> — — 3 <br /> i <br /> L(TIE)5 B06 B06 PERMIT# - <br /> �; — I I Z38B Z38B I I I I I I I I <br /> c c c c <br /> APN# 058-66-012 <br /> s – – 1 L-6 <br /> LCP-14 <br /> Q (TIE) DATE: 4/15/19 <br /> L37 <br /> 6LP , 06 DRAWN: DW <br /> c c CHECKED: JC <br /> IK <br /> 1L-29 Z38 Z38B <br /> 1 2 3 4 5 6 7 8 9 10 11 11.912 13 14 15 16 17 18 19 (20 <br /> SHEET TITLE: <br /> 1 — ELECTRICAL <br /> LIGHTING PLAN - <br /> LEVEL 1 <br /> ELECTRICAL LIGHTING PLAN - LEVEL 1�\ SCALE: 1/8"=1'-0" <br /> 'C <br /> F7 <br /> C. <br /> SHEET NO.: <br /> c <br /> cv <br /> L <br /> r <br /> E1 . 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.