My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROCKY
>
262
>
1600 - Food Program
>
PR0545763
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 6:12:58 PM
Creation date
8/25/2020 2:50:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545763
PE
1624
FACILITY_ID
FA0025909
FACILITY_NAME
FAIRFIELD INN & SUITES LODI
STREET_NUMBER
262
STREET_NAME
ROCKY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
262 ROCKY LN
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� CV <br /> N U' <br /> GENERAL NOTES - POWER U <br /> A. SEE E0.1 SHEET FOR POWER GENERAL NOTES. • , w <br /> GENERAL NOTES - TELECOMMUNICATIONS ~ <br /> A. SEE E0.1 SHEET FOR TELECOMMUNICATIONS GENERAL NOTES. <br /> O N <br /> U <br /> GENERAL NOTES - FIRE ALARM <br /> M <br /> A. SEE E0.1 SHEET FOR FIRE ALARM GENERAL NOTES. Q <br /> 0 <br /> KEYNOTES RED INC ARCHITECTS <br /> 1217 J STREET,MODESTO,CA 95354 <br /> 209.522.8900 <br /> A10 PROVIDE 4-SQ BACK BOX W/SINGLE-GANG MUDRING FOR FLUSH-MOUNTED <br /> ELECTROMAGNETIC DOOR HOLDER. PROVIDE 1/2"C W/FIRE ALARM WIRING-(2) SEAL: <br /> } #14 CU-FOR 24VAC/VDC CONNECTION TO FIRE ALARM SYSTEM. LOCATE <br /> MAGNET ON WALL BEHIND DOOR PER MANUFACTURER'S RECOMMENDATIONS <br /> (-2'-4'AFF&-6 FROM LOCK STILE AT DOOR)AND COORDINATE FINAL <br /> LOCATION W/GC. <br /> QR S/pNq <br /> pN J.Cp 2 <br /> A30 PROVIDE ADDRESSABLE RELAY MODULES FOR THE ELEVATOR, RECALL,AND <br /> 2D SHUT-DOWN. TIE TO ELEVATOR EQUIPMENT ROOM DETECTOR(S), HOISTWAY m <br /> 2R-2 DETECTOR(S),AND LOBBY DETECTOR(S)TO INITIATE RECALL AND SHUT-DOWN. cr No. E 21841 <br /> (TIE) PROVIDE ADDRESSABLE MONITOR MODULE TO MONITOR THE CONTROL EXP:03/31/2019 <br /> 2C CIRCUIT VOLTAGE TO THE ELEVATOR SHUNT TRIP. LOSS OF VOLTAGE SHALL F <br /> CAUSE A SUPERVISORY SIGNAL AT'FACP'. COORDINATE EXACT LOCATIONS sT T <br /> AND CONNECTIONS W/GC AND ELEVATOR CONTRACTOR FOR ACTUAL OF CA\,\FCID ° <br /> m 2L EF-12 ELECT2B EQUIPMENT INSTALLED. 04/15/2019 <br /> m <br /> 1 L <br /> J4, A33 PER CBC 1007.8, PROVIDE 2-WAY COMMUNICATION BETWEEN EACH ELEVATOR <br /> V2R 2A LANDING ONE OR MORE STORIES ABOVE OR BELOW THE STORY OF EXIT CONSULTANT: <br /> DISCHARGE AND A CENTRAL CONTROL POINT APPROVED BY THE FIRE <br /> T3 DEPARTMENT. BASIS-OF-DESIGN:CORNELL COMMUNICATIONS'4200 SERIES <br /> AUDIO RESCUE ASSISTANCE SYSTEM'OR EQUAL. <br /> E45 FOR EXHAUST FAN TIME CLOCK, PROVIDE DIGITAL,ASTRONOMIC& <br /> 1 LEVEL 2 ELECTRICAL ROOM SCALE: 1/4"=1'-0" PROGRAMMABLE 24-HOUR TIMER SWITCH(BASIS-OF-DESIGN:LEGRAND(P&S) <br /> E2.2 #RT24 OR EQUAL). <br /> i <br /> E78 SEE GUESTROOM CIRCUITING NOTES ON E4.2 FOR GUESTROOM BRANCH ll:mmm� <br /> I- CIRCUITING INFORMATION.SEE ALSO PANEL SCHEDULES. ENGINEERING SYSTEM SOLUTIONS <br /> LL STRUCTURAL•MEP•BUILDING COMMISSIONIN <br /> BUILDING RELATIONSHIPS <br /> T3 INTERMEDIATE DISTRIBUTION FRAME/HUB TERMINAL BACKBOARD'IDF. EXCEEDING EXPECTATIONS <br /> PROVIDE(1)4'X8'SHEETS OF 3/4"PLYWOOD(MOUNTED VERTICALLY)PAINTED www.es2eng.com <br /> WHITE WITH FIRE-RETARDANT PAINT.COORDINATE WORK WITH GC. PROVIDE 4943 NORTH 29TH EAST,STEA <br /> (2)2"C(EMT)BETWEEN 3RD FLOOR AND 2ND FLOOR'IDFAND FROM 2ND FLOOR IDAHO FALLS,IDAHO 83401 <br /> 'IDF'TO 1 ST FLOOR MATY ROOM FOR BACKBONE CABLING OF TELEPHONE/DATA PHONE:(208)552-9874 <br /> AND COAX CABLE DISTRIBUTION SYSTEMS. JOB NUMBER: 17.1019 <br /> TIRSEPLANS,DRAWEJGS Aim DESIGNS ARE THEIXCLUSNE PROPERTYOF NJO <br /> SYSTEMSTIONSANDSHALLNOTBEREPRODUCEDM FORMWITHOUT WRITTEN <br /> OLA <br /> CONSENT.ALLRbHTS ARE RESERVED.COPYRIGHT 2018 ENGBJEERBJG SYSTEM SOLUTIONS <br /> T23 FOR EACH ADMINISTRATIVE TELEPHONE LOCATION, PROVIDE(1)CAT6 UTP <br /> CABLE FROM TELEPHONE OUTLET CONTINUOUS TO MATY ROOM. HOUSE <br /> PHONES MUST RING DIRECTLY TO THE SYSTEM OPERATOR. <br /> 0 0 0 <br /> T42 EC TO COORDINATE CARD READER ELECTRICAL REQUIREMENTS W/ <br /> ARCHITECT/OWNER. IF HARD WIRED CARD READERS ARE TO BE INSTALLED, <br /> PROVIDE 4 SQUARE BACKBOX AND 1/2"C FOR BRANCH CIRCUITING. ROUTE <br /> BRANCH CIRCUIT TO NEAREST PANELBOARD DEDICATED TO PLUG LOADS.ALSO <br /> PROVIDE <br /> CABLING AS QUIREED.COORDINATE ALL REQUIREMENTS W/EST ACCESSIBLE LING FOR 1p, <br /> a 00 00DATTAa <br /> ARCHITECT/OWNER PRIOR TO ROUGH-IN. � H H o O u � O E O <br /> oOl 00G�3IOD0000 <br /> 1 2 3 4 5 6 7 8 9 (10 (11 11.912 (13 (14 (15 (16 (17 (1818.1 19 20 <br /> O O Tj O O O O 00 <br /> z <br /> 0 <br /> — — — — — — — — — — — — — — — <br /> B O U <br /> D� 1 7D <br /> I I I I I <br /> vx//O <br /> I I o0 <br /> 2R-5 <br /> HOUSEKEEPING <br /> 211 Q <br /> 0 REC <br /> TO REC BOVE LIN <br /> —BELOW' (TYP) TYP) n'P) 23 <br /> E78 E78 E78 <br /> O <br /> J_ <br /> U <br /> IR 1 L <br /> 2R-12 z <br /> R ELL <br /> • <br /> mA10 T23EM <br /> 0 <br /> EF-11 A30 SD 2R-3 F O <br /> I SD A33 <br /> SD SD COR IDOR 2R 1 CORRID((@ S O _ <br /> a <br /> 23 <br /> 6 G Z Q <br /> T42 I <br /> E2.2 T MECHA I2R-2 A10 0 <br /> U J <br /> 235 234 (TIE) <br /> 2R-7 2.2 <br /> 0 REC <br /> TO REC BELO <br /> .532R-9,11 BOVE REVISIONS: <br /> p o TYP (TYP) TYP UNDR 2 FRANCHISE 11/06/18 <br /> E78 E78 E78 <br /> EF-138 <br /> E45 <br /> 2R 8 T } <br /> m STORAGE <br /> Q 1 <br /> 0 <br /> 2R-10 <br /> (6.9 -- — — — G.9 <br /> zv <br /> H <br /> `13 1H.10� _ _ _ _ _ _ H.1) BA PROJECT# 161010 <br /> PLN PROJECT# 17077 <br /> — — — — — — — — — — — — — — — MARRIOTT# 4476 <br /> U — — — — — — — — — — — — — — — — • — — — — — — — — — — PERMIT# - <br /> �; <br /> APN# 058-66-012 <br /> U <br /> N <br /> r.. <br /> t <br /> Q <br /> DATE: 4/15/19 <br /> DRAWN: DW <br /> CHECKED: JC <br /> O� — — I — — I — — I — — I — — I — —I ° • � — � — I— — I I — — I — — I — — I — I — — I — � I —I <br /> � � SHEET TITLE: <br /> 1 2 3 4 5 6 7 8 9 (10 11 11.912 (13 (14 15 16 17 (1818.1 19 20 ELECTRICAL POWER <br /> & SPECIAL SYSTEMS <br /> PLAN - LEVEL 2 <br /> — = <br /> � ELECTRICAL POWER & SPECIAL SYSTEMS PLAN _ LEVEL 2�� SCALE: 1/8" 1'-0" <br /> 'C <br /> d <br /> r� <br /> SHEET NO.: <br /> c <br /> 3 <br /> c� <br /> L <br /> r <br /> E2 .2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.