Laserfiche WebLink
� CV <br /> N cn <br /> EXHAUST FAN EF DEDICATED OUTSIDE AIR UNIT DOAS AIR DEVICE SCHEDULE U <br /> ( ) ( ) , <br /> DAMPER ELECTRICAL HOT GAS MARK FLOW TYPE FACE SIZE NECK SIZE CFM RANGE MAX T.P. N.C.MAX THROW MODEL NOTES w <br /> OPER DX COOLING NATURAL GAS HEAT ELECTRICAL DIMENSIONS <br /> ESP FAN MAX (GRAVITY CONTROL OPENING EAT MANUFACTURER MIN REHEAT 6110 <br /> "0 0-140 0.08 19 4-7-9 <br /> � MARK LOCATION TYPE CFM ° WT NOTES SA ESP MANUFACTURER �� �� <br /> (IN WC) RPM SONES OR METHOD SIZE ( F) HP VOLT PH &MODEL MARK OSA MIN EAT MIN LAT MAX MIN MIN MAX NOTES 1 CEILING SUPPLY 12 x 12 TITUS TDCA 1,2,5,6 <br /> O Zv MOTOR) (LBS) (CFM) (INWC) OSA NUMBER OF MIN LAT INPUT MIN L W H &MODEL 8"0 141 185 0.08 20 4-7-11 <br /> (CFM) (DBIWB) (DBIWB) TEMP COMPRESSORS EER (°F) HUMIDITY (MBH) OUTPUT EFF STAGES VOLTAGE PHASE MCA MFS (IN) (IN) (IN) WEIGHT U <br /> EF-1 MENS RR 140 CEILING 150 0.5 1100 5.0 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1.2 (F) (F) GRAINS (MBH) (%) (LBS) 8"0 0-245 0.08 21 6-9-13 <br /> MEF-2 WOMENS RR 139 CEILING 150 0.5 1100 5.0 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1,2 DOAS-1 5335 i 5335 i 1.5 96.7/73.2 55/55 100 2 1 11.2 75 65 405 1 324 80 10 208 3 146 175 1110 , 60 58 3300 1 AAON RN 1 1-11 <br /> EF-3 FITNESS 137 CEILING 150 0.5 1100 5.0 GRAVITY TIMECLOCK N/A 70 0.17 120 1 20 COOK GC 1,2 2 CEILING SUPPLY 15 x 15" 10,10 246-30 0.08 19 6-9-13 TITUS TDCA 1,2,5,6 Q <br /> o NOTES: <br /> EF-5 ELECTRICAL 135 CEILING 50 0.5 900 2.0 GRAVITY T-STAT N/A 70 0.17 120 1 20 COOK GC 1,2 1. AAON,CARRIER,TRANE,AND DAIKIN ARE APPROVED MANUFACTURERS. REFER TO MANUFACTURER&MODEL FOR BASIS OF DESIGN. 12"0 301 -440 0.08 20 7-10-15 RED INC ARCHITECTS <br /> 2. UNIT SIZED USING ASHRAE EVAPORATION WB/MCDB 0.4%FOR DEHUMIDFICATION DB/WB 73.2/96.7°F.INDOOR RETURN TEMPERATURE:SUMMER DB/50%RH 757;WINTER DB 707. 1217 J STREET,MODESTO,CA 95354 <br /> EF-6 FOOD PREP 132 CEILING 100 0.5 1050 3.5 GRAVITY TIMECLOCK N/A 70 0.17 120 1 20 COOK GC 1,2 ( ) ( ) ( ) 6"0 0-140 0.08 18 4-7-9 zo9.szz.a9oo <br /> EF-7 COMM LAUNDRY CEILING 200 0.5 1200 5.0 GRAVITY TIMECLOCK N/A 70 0.17 120 1 20 COOK GC 1,2 3. PROVIDE THE FOLLOWING:VIBRATION ISOLATION ROOF CURB FOR VERTICAL DISCHARGE,THROUGH-THE-BASE ELECTRICAL WITH FACTORY MOUNTED DISCONNECT,CONVENIENCE OUTLET FOR FIELD WIRE,TDAY PROGRAMMABLE THERMOSTAT,HUMIDISTAT,AND <br /> EF-8 MARKET 114 CEILING 200 0.5 1200 5.0 1 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1,2 COMPLETE INTEGRAL CONTROL.PROVIDE WITH FOIL-FACED FIBERGLASS CABINET INSULATION OR CLOSED-CELL ELASTOMERIC INSULATION. 8"0 141 -245 0.08 20 6-9-13 <br /> EF 9 BOILER RM INLINE 200 0.4 1420 6.5 GRAVITY T STAT N/A 70 0.17 120 1 90 COOK SAND 1,2 4. PROVIDE WITH FACTORY MOUNTED SMOKE DETECTOR IN SUPPLY AIR STREAM FOR UNIT SHUTDOWN. SEAL: <br /> 5. DESIGNED FOR 100%OUTSIDE AIR.PROVIDE WITH SUPPLY AIR TEMPERATURE CONTROLS WITH THERMOSTAT AND HUMIDISTAT OVERRIDE. 10,10 246-300 0.08 19 6-9-14 <br /> J EF-10 GUEST LAUNDRY CEILING 100 0.5 1050 3.5 GRAVITY TIMECLOCK N/A 70 0.17 120 1 20 COOK GC 1,2 6. PROVIDE WITH DIRECT DRIVE SUPPLY FAN WITH VFD AND DUCT PRESSURE SENSOR.VFD TO MODULATE TO MAINTAIN DUCT PRESSURE SET POINT. 3 CEILING SUPPLY 24"x 24" TITUS TDCA 1,2,5,6 <br /> EF-11 2ND LVL ICE MAKER CEILING 200 0.5 1200 5.0 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1,2 7. PROVIDE WITH MERV 8 PRE-FILTER AND MERV 12 SECONDARY FILTERS.PROVIDE FULLY SYNTHETIC MEDIA WITH SPECIAL SUPPORTING STRUCTURE TO PREVENT MOISTURE LADEN FILTER COLLAPSE.ESP DOES NOT INCLUDE FILTER PRESSURE DROP. <br /> 12"0 301 -455 0.08 21 8-12-18 <br /> EF-12 2ND LVL ELECT CEILING 50 0.5 900 2.0 GRAVITY T-STAT N/A 70 0.17 120 1 20 COOK GC 1,2 8. FACTORY ASSEMBLED,PIPED,WIRED AND TESTED AS A SINGLE PACKAGE. 14"0 456-640 0.08 22 9-14-21 <br /> 9. UNIT TO INCLUDE MINIMUM 10:1 TURNDOWN MODULATING NATURAL GAS HEATING WITH STAINLESS STEEL HEAT EXCHANGER. e�oF s oN <br /> EF 13 POOL EQUIP RM CEILING 100 0.5 1050 3.5 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1,2,3 16"0 641 -840 0.08 21 11 -17-24 GN N.Stq�qeF <br /> 10.2"FOAM INJECTED INSULATED(MINIMUM R13 VALUE)DOUBLEWALL CABINET CONSTRUCTION. <br /> EF-14 3RD LVL MAINTENANCE CEILING 70 0.5 1000 3.5 GRAVITY WALL SWITCH N/A 70 0.17 120 1 20 COOK GC 1,2 11.UNIT TO HAVE MODULATING HOT GAS RE-HEAT FOR DEHUMIDIFICATION AND DELIVER 75 F @ 50%RH AT DESIGN CONDITIONS. <br /> 480-250 <br /> "x 61/2" 8"0 0.08 13 a <br /> EF-15 3RD LVL ICE MAKER CEILING 200 0.5 1200 5.0 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1,2 w m <br /> 4 LINEAR DIFFUSER TITUS FL-10 1,2,4,6 M37119 <br /> EF-16 3RD LVL ELECT CEILING 1 50 0.5 900 2.0 GRAVITY T-STAT N/A 70 0.17 1 120 1 20 COOK GC 1,2 48"x 6 1/2" 10,10 251 -290 0.08 16 11 -17-25 EXP.9-30-2020 <br /> EF-18 KITCHEN CEILING 70 0.5 1000 3.5 GRAVITY CONTINUOUS N/A 70 0.17 120 1 20 COOK GC 1,2 <br /> EF-19 1ST LVL ICE MAKER CEILING 200 0.5 1200 5.0 GRAVITY TIMECLOCK N/A 70 0.17 120 1 20 COOK GC 1,2 ELECTRIC WALL HEATER (EH) 10"x 8" 8"x 6" 0-215 0.08 23 7-8-12 <br /> �T�FC N\cP�, <br /> ® CEILING 50 0.4 1100 1.0 GRAVITY HUMIDITY N/A 70 0.17 120 1 20 PANASONIC 1,2,4 14"x 8" 12"x 6" 216-280 0.08 23 8-10-14 qTF OF CA`\ o� <br /> m EF-A GUESTROOMS ELECTRICAL DIMENSIONS OPER <br /> cuWALL SWITCH FV-05VK3MANUFACTURER& <br /> D MARK LOCATION TYPE CFM EAT(°F) MOUNTING #STEPS WT NOTES 5 WALL SUPPLY 10"x 10" 8"x 8" 281 -480 0.08 25 18-22-31 TITUS 272R 1,2,6 04/12/2019 <br /> m KW AMPS VOLT PH L W H (LBS) MODEL <br /> NOTES: EH-1 NORTH STAIRS WALL 160 60 SURFACE 1 2.25 11.2 208 1 16 5 22 30 INDEECO WCI 1,2,3 <br /> 12"x 12" 10"x 10" 481 -700 0.072 25 19-25-35 <br /> 1. COOK,GREENHECK,PENNBARRY,AND CAPTIVEAIRE ARE APPROVED MANUFACTURERS.REFER TO MANUFACTURER AND MODEL FOR BASIS OF DESIGN. EH-2 ENTRY VESTIBULE WALL 160 60 RECESSED 1 1.125 5.8 208 1 16 5 22 30 INDEECO WCI 1,2,3 16"x 16" 14"x 14" 701 -1295 0.049 25 26-34-48 <br /> 2. PROVIDE WITH VIBRATION ISOLATION AND FAN SPEED CONTROLLER. CONSULTANT: <br /> 3. EQUIPMENT TO BE ALUMINUM CONSTRUCTION. EH-3 SOUTH STAIRS WALL 160 60 SURFACE 1 1 2.25 11.2 208 1 16 5 22 30 1 INDEECO WCI 1,2,3 14"0 6"0 0-170 0.13 21 3-5-8 <br /> 4. FANS TO BE ENERGY STAR RATED.WALL SWITCH WITH INTEGRAL HUMIDITY SENSOR BY EC. EH-4 BOILER RM WALL 160 60 SURFACE 1 1 1 1.125 1 5.8 1 208 1 1 1 16 1 5 1 22 30 1 INDEECO WCI 1,2,3 <br /> 18"0 8"0 171 -295 0.13 23 4-7-11 <br /> NOTES: 6 CEILING SUPPLY 23"0 10,10 296-460 0.13 25 5-8-13 TITUS TMRA 1,2,6 <br /> 1. QMARK,� 2. PROVIDE WITH INTHERMOSTAT.INDEECO, <br /> TEGRAL APPROVED MANUFACTURERS.REFER TO MANUFACTURER AND MODEL FOR BASIS OF DESIGN. 27"0 12"0 461 -630 0.12 25 7-11 -16 <br /> PACKAGED TERMINAL HEAT PUMP UNIT (PT) 3. COLOR BY ARCHITECT. <br /> ELECTRIC ELECTRICAL DIMENSIONS(IN) 32"0 14"0 631 825 0.11 25 8-11 -19 <br /> OSA NOM HEAT HEATING OPER WT 12"x 5" 12"x 3" 0-110 0.13 23 6-7-11 <br /> MARK CFM COOLING PUMP NOM EER STAGES MANUFACTURER&MODEL NOTES ENGINEERING SYSTEM SOLUTIONS <br /> CFM CAP(MBH) CAP(MBH) CAPACITY MCA MOCP VOLT PH L W H (LBS) FAN COIL (FC) 7 DUCT SUPPLY 12"x 6" 12"x 4" 111 -165 0.13 25 7-9-13 TITUS S300 1,2,6 STRUCTURAL•MEP•BUILDING COMMISSIONING <br /> BUILDING RELATIONSHIPS <br /> PTA 360 35 7300 6700 11.3 1 2 9.7 15 208 -1 -F-2-2 42 16 125 GE AZ65H07DBM 1,2,3 OSA ESP MIN HEATING ELECTRICAL DIMENSIONS(IN) OPER WT MANUFACTURER& 12"x 8" 12"x 6" 166-230 0.13 25 9-11 -15 EXCEEDING EXPECTATIONS <br /> MARK SERVING CFM (CFM)* (IN WC) EAT°F(DBIWB) LAT°F(DBIWB) (MBH) MCA MOCP VOLT PH D W H (LBS) MODEL NOTES 8"x 8" 6"x 6" 0-100 0.12 <br /> NATES: - www.es2eng.com <br /> 4943 NORTH 29TH EAST,STE A <br /> 1.AMANA AND GENERAL ELECTRIC ARE APPROVED MANUFACTURERS.REFER TO MANUFACTURER AND MODEL FOR BASIS OF DESIGN FC-1 EVENT 1200 610 0.5 75/60 55/52 32 10 15 208 1 22 25 59 220 SAMSUNG AC 1,2,3,4,5,6 10"x 10" 8"x 8" 101 -190 0.12 10 IDAHO NED 0IDAHO <br /> D sz 98744 <br /> 2.PROVIDE INNCOM E4 SMART DIGITAL OCCUPANCY THERMOSTAT,AND WALL COLLAR. CENTER <br /> 3.PROVIDE WITH MAKEUP AIR MODULE WITH SEPARATE OUTDOOR AIR FAN. FC-2 MEETING RM 800 1 370 0.5 75/60 55/52 18 10 15 208 1 18 21 40 150 SAMSUNG AC 1,2,3,4,5 CEILING I WALL 12"x 12" 10"x 10" 191 -300 0.12 10 1 2 JOB NUMBER: 17.1019 <br /> FC-3 EXERCISE RM 800 90 0.5 75/60 55/52 18 10 15 208 1 18 21 40 150 SAMSUNG AC 1,2,3,4,5 EXHAUST 14"x 14" 12"x 12" 301 -450 0.12 12 Sy�E-,OR- DESIGIS ARE TIE E-1 S-PROPERTY OF ENGWEE- <br /> «a �s^atRtst_O . R1=011-6-�GSISTENIsOLLT1O^s <br /> FC-4 BREAFAST RM 1600 625 0.5 75/60 55/52 36 10 15 208 1 1 22 1 25 59 250 SAMSUNG AC 1,2,3,4,5,6 8 TITUS 8F <br /> GUESTROOM VENTILATION CALCULATIONS FC-5 LAUNDRY 1000 250 0.5 75/60 55/52 27 10 15 208 1 28 51 12 100 SAMSUNG AC 1,2,3,4,5,7 16"x 16" 14"x 14" 451 -625 0.12 13 <br /> FC-6 LOBBY 1600 240 0.5 75/60 55/52 36 10 15 208 1 22 25 59 250 SAMSUNG AC 1,2,3,4,5,6 20"x 20" 18"x 18" 626-1065 0.12 16 <br /> MINIMUM FC-7 FOOD PREP 600 70 0.5 75/60 55/52 18 10 15 208 1 28 47 10 90 SAMSUNG AC 1,2,3,4,5,7 <br /> VENTALATION 24"x 24" 22"x 22" 0-610 0.06 20 <br /> ROOM TYPE AREA(SQ FT) VENTALATION REQUIRED PROVIDED FC-8 EVENT 2200 730 0.5 75/60 55/52 48 10 15 208 1 22 25 59 250 SAMSUNG AM 1,2,3,4,5,6 CEILING EXHAUST 1,2 <br /> VENTALATION (CFM) CENTER - <br /> 24"x 12" 22"x 10" 611 -1340 0.06 <br /> (CFM) *VENTILATION AIR IS TO BE DELIVERED BY DOAS-1 " " " " Fakfield ACC DBL QUEEN 340 NOTE 1 30 35 12 x 12 10 x 10 0 270 0.06 12 <br /> NOTES: <br /> ACC KING 285 NOTE 1 30 35 1. TRANE,CARRIER,LENNOX,SAMSUNG AND YORK ARE APPROVED MANUFACTURERS.REFER TO MANUFACTURER AND MODEL FOR BASIS OF DESIGN. 14"x 14" 12"x 12" 271 -400 0.06 12 <br /> ACC KING ROLL-IN 260 NOTE 1 30 35 2. PROVIDE WITH FOIL-FACED FIBERGLASS CABINET INSULATION OR CLOSED-CELL ELASTOMERIC INSULATION. <br /> ACC KING SUITE 355 NOTE 1 30 35 3. ESP INCLUDES EXTERNAL DUCTING ONLY.ESP DOES NOT INCLUDE PRESSURE DROP THROUGH EVAPORATOR COIL,HEAT COIL,OR AIR FILTER. CEILING I WALL 18 x 18 16„x 16 401 740 0.06 14 1 N N & SUITES <br /> 20 x 20 18 x 18„ <br /> DBL QUEEN 255 NOTE 1 30 35 4. PROVIDE 7-DAY PROGRAMMABLE THERMOSTAT AND MERV-8 FILTER.INSTALL RETURN AIR BASED ON MANUFACTURER RECOMMENDATIONS TO ATTAIN SCHEDULED AIRFLOW. RETURN TITUS 355R 1,2 <br /> 741 -950 0.06 15 <br /> DBL QUEEN ALT 300 NOTE 1 30 35 5. <br /> FILTER PROVIDE WITH 22"x 22" 20"x 20" 951 -1175 0.06 15 <br /> FROM MAIN FIRE CONTROL PANEL TO FAN COIL.FAN COILS TO SHUT DOWN UPON DETECTION OF SMOKE FROM ANY AREA SMOKE DETECTOR. 9 B Y MARRIOTT <br /> 6. PROVIDE RELAY <br /> KING 200 NOTE 1 30 35 7. UNIT TO BE INSTALLED HORIZONTAL ABOVE CEILING SPACE. <br /> KING SUITE 285 NOTE 1 30 35 24"x 24" 22"x 22" 1176-1440 0.06 15 <br /> NOTES: 24"x 12" 22"x 10" 0-610 0.06 20 <br /> CEILING RETURN TITUS PXP 1,2,5 <br /> 1. PER 2016 EFFICIENCY STANDARDS TABLE 120.1-A,GUEST ROOMS LESS THAN 500 FT^2 REQUIRE MINIMUM 30 HEAT PUMP (H P) 24"x 24" 22"x 22" 611 -1340 0.06 - <br /> CFM VENTILATION AIR.GUEST ROOMS 500 FT"2 AND LARGER REQUIRE MINIMUM 0.15 CFM/FTA 2 VENTILATION AIR. <br /> NOM COOLING <br /> HEATING ELECTRICAL DIMENSIONS OPER 8"x 8" 6"x 6" 0-60 0.03 10 <br /> OSA MANUFACTURER& 10"x 10" 8"x 8" 61 -120 0.03 10 <br /> MARK LOCATION HEATING OSA TEMP TEMP HSPF SEER MCA MOCP VOLT PH L W H WT CORR UNIT MODEL NOTES <br /> (MBH) (°F) (°F) (LBS) CEILING/WALL 12"x 12" 10"x 10" 121 -190 0.03 10 TITUS 355R 1,2 Q <br /> HP-1 ROOF 36 100 20 9 14 27 40 208 1 37 13 48 225 FC-1 SAMSUNG AC 1,2,3 TRANSFER 14"x 14" 12"x 12" 191 -285 0.03 10 Z <br /> HP-2 ROOF 24 100 20 9 14 14 20 208 1 37 13 40 175 FC-2 SAMSUNG AC 1,2,3 10 ly- <br /> 16"x 16" 14"x 14" 286-390 0.03 10 O <br /> HP-3 ROOF 24 100 20 9 14 14 20 208 1 37 13 40 175 FC-3 SAMSUNG AC 1,2,3 <br /> 18"x 18" 16"x 16" 391 -520 0.03 10 <br /> HP-4 ROOF 48 100 20 9 14 27 40 208 1 37 13 48 225 FC-4 SAMSUNG AC 1,2,3 U <br /> HP-5 ROOF 30 100 20 9 14 23 30 208 1 37 13 48 225 FC-5 SAMSUNG AC 1,2,3 24"x 12" 22"x 10" 0-450 0.04 13 <br /> HP-6 ROOF 48 100 20 9 14 27 40 208 1 37 13 48 225 FC-6 SAMSUNG AC 1,2,3 CEILING TRANSFER TITUS PXP 1,2,5 <br /> 24"x 24" 22"x 22" 451 -1000 0.04 - <br /> HP-7 ROOF 18 100 20 9 14 14 20 208 1 37 13 40 175 FC-7 SAMSUNG AC 1,2,3 <br /> HP-8 ROOF 1 72 1 100 20 3.3 COP 11 EER 28 35 208 1 3 1 37 1 37 1 48 1 225 FC-8 SAMSUNG AM 1,2,3 7 1/2"x 7 1/2" 4"0 0-40 0.2 20 <br /> 11 CONSTANT FLOW 71/2"x 7112" 5"0 41 -60 0.2 20 _ -R-II CSR-R-II/CER <br /> NOTES: SUPPLY OR EXHAUST 1,3 <br /> 1. LENNOX,TRANE,SAMSUNG,CARRIER,AND YORK ARE APPROVED MANUFACTURERS.REFER TO MANUFACTURER AND MODEL FOR BASIS OF DESIGN. 91/2"x 9 1/2" 6"0 61 -100 0.2 20 <br /> 2. PROVIDE WITH LOW AMBIENT KIT,AND TXV REFRIGERANT METERING DEVICE. <br /> 3. PROVIDE ROOF CURB.(REFER TO"TYPICAL ROOF-MOUNTED CONDENSING UNIT/HEAT PUMP"DETAIL) *REFER TO FLOOR PLANS FOR THROW PATTERN/ARROWS. SUPPLY AIR DEVICE INTENDED TO BE 4-WAY THROW IF PATTERN/ARROWS ARE <br /> NOT INDICATED. <br /> CONDENSING UNIT (CU) **NOT ALL AIR DEVICES IN THE AIR DEVICE SCHEDULE ARE USED. <br /> NOTES: <br /> NOM OSA MIN ELECTRICAL DIMENSIONS(IN) OPER MANUFACTURER& 1. PROVIDE FRAME COMPATIIBLE WITH CEILING OR WALL TYPE. VERIFY FRAME TYPE OF ALL AIR DEVICES WITH ARCHITECTURAL <br /> MARK LOCATION COOLING TEMP SEER VOLT PHASE MCA MOCP L W H WT(LBS) CORR UNIT MODEL NOTES <br /> (MBH) (°F) REFLECTED CEILING PLAN BEFORE ORDERING. COLOR BY ARCHITECT. <br /> CU-1 ROOF 18 100 15 208 1 18 30 32 13 24 125 AC-1 MITSUBISHI PUY 1,213 2. TITUS, CARNES, PRICE,AND KRUEGER ARE APPROVED MANUFACTURERS. REFER TO MANUFACTURER AND MODEL FOR BASIS OF DESIGN. <br /> CU-2 ROOF 18 100 15 208 1 18 30 32 13 24 125 AC-2 MITSUBISHI PUY 1,2,3 <br /> CU-3 ROOF 18 100 15 208 1 18 30 32 13 24 125 AC-3 MITSUBISHI PUY 1,2,3 3. AMERICAN ALDES IS APPROVED MANUFACTURER. CONSTANT FLOW OF 35 CFM TO BE MANINTAINED BETWEEN SYSTEM PRESSURES OF <br /> NOTES: 0.2 AND 0.8 IN.WG. PROVIDE WITH RADIATION DAMPER. <br /> 1. LG,DAIKIN,SAMSUNG,MITSUBISHI AND FUJITSU ARE APPROVED MANUFACTURERS.REFER TO MANUFACTURER FOR BASIS OF DESIGN. 4. DIFFUSER TO HAVE(2)1"SLOTS. PROVIDE PLENUM ATTECHMENT FOR LINEAR DIFFUSER. <br /> 2. PROVIDE LOW AMBIENT KIT,TXV REFRIGERANT METERING DEVICE,AND MOUNTING PAD.(REFER TO"TYPICAL ROOF-MOUNTED CONDENSING UNIT/HEAT PUMP"DETAIL), <br /> 3. INDOOR UNIT POWERED BY OUTDOOR UNIT. 5. 24"x 24"OR 24"x 12"AIR DEVICES TO BE USED IN LAY-IN GRID CEILINGS. VERIFY CEILING TYPE WITH ARCHITECT. <br /> 6. THROW VALUES ARE FOR TERMINAL VELOCITIES OF 150 FPM, 100 FPM,AND 50 FPM, RESPECTIVELY. OU- <br /> U) <br /> MINI SPLIT AC UNIT (AC) <br /> AIRFLOW OSA DX COOLING DIMENSIONS ELECTRICAL MANUFACTURER&MODEL <br /> MARK LOCATION (CFM) CFM TOTAL <br /> EAT(°F) L(IN) W(IN) H(IN) (LBS) VOLTAGE PHASE MCA MFS NO, NOTES <br /> z <br /> 0 <br /> 46 AC-1 ELEV EQUIP 700 N/A 18 80 12 47 15 75 208 1 1.0 15 MITSUBISHI PKA 1,2 U <br /> pq AC-2 MAN 700 N/A 1 18 80 12 47 15 75 208 1 1.0 15 MITSUBISHI PKA 1,2 <br /> AC-3 AV ROOM 700 N/A 1 18 1 80 1 12 1 47 1 15 1 75 1 208 1 1 1.0 1 15 1 MITSUBISHI PKA 1,2 Z O <br /> NOTES: J <br /> 1. LG,DAIKIN,SAMSUNG,MITSUBISHI AND FUJITSU ARE APPROVED MANUFACTURERS. <br /> 2. PROVIDE WITH TDAY PROGRAMMABLE THERMOSTAT,AND CONDENSATE PUMP.INDOOR UNIT POWERED BY OUTDOOR UNIT. <br /> 2- <br /> LOUVER (LV) REVISIONS: <br /> 2 FRANCHISE 11/06/18 <br /> MARK CFM VELOCITY(FPM) MIN FREE AREA PRESSURE DIMENSIONS(IN) MANUFACTURER&MODEL NOTES <br /> (SQ FT) DROP W H <br /> LV-1 200 800 0.34 0.13 12 12 RUSKIN ELF375DX 1,2 <br /> LV-2 550 800 0.69 0.13 16 16 RUSKIN ELF375DX 1,2 <br /> LV-3 1120 800 1.4 0.13 18 24 RUSKIN ELF375DX 1,2 <br /> LV-4 3615 800 4.52 0.13 36 36 RUSKIN ELF375DX 1,2,3 <br /> CL <br /> Q NOTES: <br /> 1. RUSKIN,AMERICAN WARMING&VENTILATION CO.,&ARROW UNITED ARE APPROVED MANUFACTURERS. <br /> 2. PROVIDE WITH BIRD SCREEN. COLOR BY ARCHITECT. <br /> 3. FREE AREA TO BE VERIFIED WITH FINAL DRYER REQUIREMENTS PRIOR TO PURCHASE/INSTALLATION. <br /> m BA PROJECT# 161010 <br /> PLN PROJECT# 17077 <br /> MARRIOTT# 4476 <br /> Fm <br /> U PERMIT# - <br /> APN# 058-66-012 <br /> U <br /> N <br /> r.. <br /> L <br /> Q <br /> DATE: 4/12/19 <br /> DRAWN: CB <br /> CHECKED: HS <br /> SHEET TITLE: <br /> MECHANICAL <br /> SCHEDULES <br /> 'C <br /> a SHEET NO.: <br /> c <br /> 3 <br /> c>3 <br /> L <br /> r <br /> M6. 1 <br />