My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROCKY
>
262
>
1600 - Food Program
>
PR0545763
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 6:12:58 PM
Creation date
8/25/2020 2:50:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545763
PE
1624
FACILITY_ID
FA0025909
FACILITY_NAME
FAIRFIELD INN & SUITES LODI
STREET_NUMBER
262
STREET_NAME
ROCKY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
262 ROCKY LN
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ELECTRICALCAST IRO NBATHVILLAG ERK-716 <br />CAST IRO NBATHVILLAG ERK-716 CAST IRO NBATHVILLAG ERK-716 CAST IRO NBATHVILLAG ERK-716CAST IRO NBATHVILLAG ERK-716 <br />CAST IRO NBATHVILLAG ERK-716 <br />SINKSINKCLEANAIR/VANPOOL/EVCLEANAIR/VANPOOL/EVC110A <br />IT <br />134 <br />HALL <br />112 <br />WELCOME DESK <br />117 <br />CORRIDOR <br />105 <br />CORRIDOR <br />120 <br />AHU <br />BOILER/ <br />131 <br />FIRE RISER <br />141 <br />MEETING ROOM <br />118 <br />MATV <br />119 <br />STORAGE <br />ST1.2 <br />STAIR 2 <br />116 <br />LOUNGE <br />107 <br />ELEV. <br />101 <br />HVAC <br />102 <br />STORAGE <br />104 <br />PREP KIT. <br />EMPLOYEE <br />109 <br />BREAKROOM <br />108 <br />LAUNDRY <br />ELEV. <br />106 <br />EQUIP. <br />110 <br />WORK <br />111 <br />OFFICE <br />115 <br />VESTIBULE <br />THE <br />CORNER <br />114 <br />MARKET <br />113 <br />LOBBY <br />133 <br />BREAKFAST <br />132 <br />FOOD PREP <br />135 <br />ELECTRICAL <br />136 <br />MECHANICAL <br />139 <br />WOMEN <br />140 <br />MEN <br />137 <br />FITNESS CENTER <br />ST1.1 <br />STAIR 1 <br />103 <br />EVENT CENTER <br />129 <br />QUEEN QUEEN <br />127 <br />QUEEN QUEEN <br />125 <br />QUEEN QUEEN <br />123 <br />QUEEN QUEEN <br />121 <br />KING <br />ACC. KING <br />130 <br />ROLL-IN <br />128 <br />QUEEN QUEEN <br />126 <br />QUEEN QUEEN <br />124 <br />KING <br />122 <br />KING <br />2 <br />2 <br />D D <br />1 <br />1 <br />3 <br />3 <br />4 <br />4 <br />5 <br />5 <br />6 <br />6 <br />7 <br />7 <br />8 <br />8 <br />9 <br />9 <br />10 <br />10 <br />11 <br />11 <br />12 <br />12 <br />13 <br />13 <br />14 <br />14 <br />15 <br />15 16 17 <br />18 <br />18 <br />19 <br />19 <br />20 <br />20 <br />K K <br />J J <br />I I <br />G G <br />F F <br />E E <br />CC <br />BB <br />AA <br />WH-1 WH-2 <br />WH-3 <br />ET-1 <br />SR <br />CWFU12.5 <br />2 <br />SR <br />CWFU12.5 <br />2 <br />SR <br />CWFU12.5 <br />2 <br />SR <br />CWFU12.5 <br />2 <br />SR <br />CWFU12.5 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />SR <br />CWFU25 <br />2 <br />CP-1 <br />4"ø DCW <br />S-1 <br />SVS-02 <br />S-DCW <br />SNK-13 <br />SNK-13 <br />WB-2 <br />SNK-39 <br />SNK-39 <br />WCL-14U-1 <br />WCL-14 <br />WCL-14 <br />WCL-15 <br />WCL-15 <br />033 <br />1"ø S-DCW UP <br />EEW-1 <br />MOP-1 <br />P3 <br />SC-1 <br />SC-1 <br />SC-1 <br />SC-1 <br />SC-1 <br />U-DCW <br />U-DCW UP <br />123 <br />WCR-51 <br />P10 <br />SOLAR UP <br />FUTURE <br />SOLAR <br />SNK-39 <br />CP-2 <br />P8 <br />P8P8 <br />P8 P8 <br />P8 <br />P8 <br />P8 <br />P8 <br />FS <br />SOLAR UP <br />HH <br />P4 <br />LS-2 <br />SR <br />CWFU18.8 <br />3 <br />SR <br />CWFU37.5 <br />3 <br />SR <br />CWFU37.5 <br />3 <br />SR <br />CWFU37.5 <br />3 <br />SR <br />CWFU37.5 <br />3 <br />SR <br />CWFU18.8 <br />3 <br />105 <br />061 <br />118 <br />1"ø <br />1"ø <br />1"ø 1 1/4"ø <br />2"ø <br />1"ø 1 1/4"ø 2"ø <br />3/4"ø <br />1"ø <br />1 1/4"ø <br />2"ø <br />2"ø <br />1"ø <br />1"ø <br />2 1/2"ø 3"ø <br />2"ø <br />1"ø <br />1"ø <br />1 1/4"ø <br />1 1/4"ø <br />4"ø <br />MV-1 <br />2"ø <br />2"ø 2 1/2"ø <br />2"ø <br />3"ø <br />BP-1 <br />H.1H.1 <br />H.5H.5 <br />G.9G.9 <br />SNK-39 <br />EEW-1 <br />SNK-13 <br />P52 <br />SNK-39 <br />SNK-39 <br />HB-1 <br />P53 <br />1"ø <br />WB-2 <br />11.9 <br />11.9 18.1 <br />18.10 1/2"1/4" 1" 2"IF THIS SHEET IS NOT 30"x42", IT IS A REDUCED PRINT - SCALE ACCORDINGLYThis drawing, printed or otherwise, is the copyrighted property of RED Inc Architects . The drawing may not be used, reproduced or copied without the permission of RED Inc Architects.REVISIONS: <br />BA PROJECT #161010CONSTRUCTION DRAWINGS FOR:DATE: <br />DRAWN:LODICHECKED: <br />PLN PROJECT #17077 <br />MARRIOTT #4476 <br />PERMIT #-CALIFORNIAAPN #058-66-012 <br />SHEET TITLE: <br />SHEET NO.: <br />SEAL: <br />CONSULTANT: <br />RED INC ARCHITECTS <br />1217 J STREET, MODESTO, CA 95354 <br />209.522.890030" x 42"JOB NUMBER: <br />THESE PLANS, DRAWINGS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF ENGINEERING <br />SYSTEM SOLUTIONS AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN <br />CONSENT. ALL RIGHTS ARE RESERVED. COPYRIGHT 2018 ENGINEERING SYSTEM SOLUTIONS <br />4943 NORTH 29TH EAST, STE A <br />IDAHO FALLS, IDAHO 83401 <br />PHONE: (208) 552-9874 <br />ENGINEERING SYSTEM SOLUTIONS <br />STRUCTURAL • MEP • BUILDING COMMISSIONING <br />www.es2eng.com <br />BUILDING RELATIONSHIPS <br />EXCEEDING EXPECTATIONS <br />17.1019 <br />This drawing, printed or otherwise, is the copyrighted property of Burkett Architect PC . The drawing may not be used, reproduced or copied without the permission of Burkett Architect PCIF THIS SHEET IS NOT 30"x42", IT IS A REDUCED PRINT -SCALE ACCORDINGLY2"1"1/4"1/2"030" x 42"4/12/19 <br />P1.1B <br />PLUMBING FLOOR <br />PLAN - LEVEL 1 ( <br />DOMESTIC COLD <br />WATER) <br />ACS <br />HS <br />SCALE: 1/8" = 1'-0"PLUMBING FLOOR PLAN - LEVEL 1 ( DOMESTIC COLD WATER)PLUMBING FLOOR PLAN - LEVEL 1 ( DOMESTIC COLD WATER)PLUMBING FLOOR PLAN - LEVEL 1 ( DOMESTIC COLD WATER) <br />GUEST ROOM - PLUMBING <br />ROOM TYPE LAVATORY WATER CLOSET BATH/ SHOWER FLOOR DRAIN <br />ACC DBL QUEEN SNK-38 WCL-12 TUB-17 FD-1 <br />ACC KING SNK-38 WCL-12 TUB-17 FD-1 <br />ACC KING ROLL-IN SNK-38 WCL-12 SHR-24 FD-1 <br />ACC KING SUITE SNK-38 WCL-12 TUB-17 FD-1 <br />DBL QUEEN SNK-37 WCL-10 TUB-16 - <br />DBL QUEEN ALT SNK-37 WCL-10 TUB-16 - <br />KING SNK-37 WCL-10 SHR-25 - <br />KING SUITE SNK-37 WCL-10 SHR-25 - <br />*REFER TO ARCHITECTURAL PLANS FOR FINAL NUMBER OF GUEST ROOMS. <br />ABBREVIATIONS LEGEND <br />SR STORY RISER <br />CWFU COLD WATER FIXTURE UNITS <br />HWFU HOT WATER FIXTURE UNITS <br />KEYNOTES <br />P3 REFER TO CIVIL FOR CONTINUATION OF DOMESTIC WATER PIPING. <br />P4 SEE CIVIL FOR CONTINUATION OF FIRE SPRINKLER. SHOWN FOR REFERENCE ONLY. <br />SIZE AND LOCATION PROVIDED BY OTHERS. <br />P8 PROVIDE ISOLATION VALVES IN ACCESSIBLE AREA. <br />P10 PROVIDE 1 1/4" SDCW CONNECTION WITH SHUT OFF VALVE TO WASHER. INSTALL PER <br />MANFACTURERS RECOMMENDATIONS. <br />P52 COORDINATE EXACT LOCATION OF WATER COOLER WITH ARCHITECT PRIOR TO <br />INSTALLATION OF PIPING AND EQUIPMENT. <br />P53 PROVIDE WATER 1" WATER LINE TO HOSE BIB IN TRASH ENCLOSURE. HOSE BIB TO BE <br />WOODFORD Y34 OR EQUAL. COORDINATE WATER ROUTING WITH CIVIL. COORDINATE <br />HOSE BIB LOCATION WITH TRASH CONTAINERS AND ARCH. <br />A. PROVIDE BACKFLOW PREVENTERS ON WATER LINE FOR ALL ICE MACHINES. <br />B. REFER TO SHEET P2.1 FOR RISER DIAGRAMS. <br />C. REFER TO SHEET P5.1 FOR TRAP PRIMER REQUIREMENTS. <br />D. ALL PIPNG ABOVE FOOD HANDLING ESTABLISHMENTS MUST COMPLY WITH THE FOLLOWING: <br />GENERAL NOTES <br />1. ALL OPENINGS THROUGH FLOORS OVER SUCH AREAS SHALL BE SEALED <br />WATERTIGHT TO THE FLOOR CONSTRUCTION <br />2. FLOOR AND SHOWER DRAINS INSTALLED ABOVE SUCH AREAS SHALL BE <br />EQUIPPED WITH INTEGRAL SEEPAGE PANS. <br />3. CLEANOUTS SHALL BE EXTENDED THROUGH THE FLOOR CONSTRUCTIONS <br />ABOVE. <br />4. PIPING SUBJECT TO OPERATION AT TEMPERATURES THAT WILL FORM <br />CONDENSATION ON THE EXTERIOR OF THE PIPE SHALL BE THERMALLY <br />INSULATED. <br />5. PIPES INSTALLED IN CEILINGS SHALL BE PROVIDED WITH ACCESS PANELS IN <br />ORDER TO FORM A READY ACCESS FOR INSPECTION OF PIPING.ALL OPENINGS <br />E <br />IN <br />ARSESIOFNO <br />L <br />OIFCALOF <br />R <br />D <br />SIERGERETT <br />S <br />A <br />ET <br />P <br />EXP. 9-30-18 <br />M37119 NREEIGN <br />AMECHA N I C A LHU G H STAIN. <br />G <br />E <br />REXP.9-30-2020 <br />04/12/2019
The URL can be used to link to this page
Your browser does not support the video tag.