R
>
ROCKY
>
262
>
1600 - Food Program
>
PR0545763
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 6:12:58 PM
Creation date
8/25/2020 2:50:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545763
PE
1624
FACILITY_ID
FA0025909
FACILITY_NAME
FAIRFIELD INN & SUITES LODI
STREET_NUMBER
262
STREET_NAME
ROCKY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
262 ROCKY LN
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 12"MIN2 <br />3 <br />4 <br />5 <br />KEYNOTES: <br />1.SINGLE PLY ROOF JACK FURNISHED <br />AND INSTALLED BY ROOFING <br />CONTRACTOR. SEAL WATERTIGHT TO <br />VENT STACK <br />2.ROOFING MATERIAL <br />3.SLEEVE ROOF CONSTRUCTION AS <br />REQUIRED <br />4.VENT STACK <br />5.INCREASER WHEN REQUIRED <br />1 2 3 4 <br />5 <br />6 <br />7 <br />896"10 <br />6 <br />FLOOR CLEANOUT (FCO) <br />CLEANOUT TO GRADE (COTG) <br />1. <br />KEYNOTES: <br />CLEANOUT AND ACCESS COVER. <br />TOP OF COVER TO BE FLUSH W/ <br />TOP OF FLOOR <br />2.FLOOR LINE <br />3.BRASS CLEANOUT PLUG W/ <br />COUNTER SUNK HEAD <br />4.FINISH GRADE <br />5.16" SQUARE CONC. PAD TROWEL <br />SMOOTH AND EDGE <br />6.1/8" BEND <br />7.WASTE LINE. LENGTH TO SUIT <br />8.WASTE LINE <br />9.1/8" BEND IF CLEANOUT OCCURS <br />AT END OF LINE <br />10.BALANCE OF PIPING SAME AS <br />CLEANOUT TO GRADE <br />A. <br />NOTES: <br />CLEANOUT NOT TO BE LOCATED IN <br />CARPETED AREA <br />1 <br />2 <br />3 <br />4 <br />5 <br />69"1. <br />KEYNOTES: <br />CHROME WALL COVER AND SCREW <br />2.MAY EXTEND AS A WASTE OR <br />VENT LINE <br />3.WALL <br />4.PLUGGED TEE <br />5.WASTE OR VENT PIPING <br />6.FLOOR LINE <br />1. <br />KEYNOTES: <br />1/4" MINIMUM DIAMETER BEAD OF 3M <br />FIRE BARRIER CP 25 CAULK OR MP <br />MOLDABLE PUTTY <br />2.WOOD OR STEEL STUD <br />3.1 OR 2 HOUR FIRE RATED GYPSUM <br />WALL BOARD <br />1 <br />1 <br />3 <br />2 <br />NOTE: <br />TYPICAL DETAILS SHOWING GENERAL FIRE <br />STOPPING PROCEDURE. ACTUAL <br />PROCEDURE DEPENDS UPON ANNULAR <br />SPACE BETWEEN PIPE AND/OR INSULATION <br />AND OPENING. FOLLOW MANUFACTURER'S <br />INSTRUCTIONS. <br />FIRESTOP FOR PIPING THROUGH GYPSUM WALL BOARD <br />1. <br />2. <br />3. <br />GYPSUM WALL BOARD <br />4" DIAMETER OR LESS TYPE <br />L COPPER DOMESTIC WATER <br />PIPE, OR 10" DIAMETER <br />LESS CAST IRON WASTE AND <br />VENT PIPE. <br />3M FB 3000 WT SEALANT <br />1 <br />2 <br />3 <br />A.MINIMUM ANNULAR SPACE <br />BETWEEN PIPE AND OPENING <br />IS 3/4". <br />B.INSTALL FIRE STOP <br />COMPOUND TO A DEPTH OF <br />1/2" FOR EACH SIDE TO A <br />MINIMUM OF 1 1/2" THICK. <br />C.INSTALL PER <br />MANUFACTURER'S <br />RECOMMENDATION TO <br />MAINTAIN ASSEMBLY RATING. <br />KEYNOTES: <br />NOTES: <br />1. <br />2. <br />3. <br />SUB FLOOR <br />FLOOR JOIST <br />3M FB 3000 WT SEALANT <br />A.MINIMUM ANNULAR SPACE <br />BETWEEN PIPE AND OPENING <br />IS 3/4". <br />B.INSTALL FIRE STOP <br />COMPOUND TO A DEPTH OF <br />1/2" ON EACH SIDE TO A <br />MINIMUM OF 1 1/2" THICK. <br />C.INSTALL PER <br />MANUFACTURER'S <br />RECOMMENDATION TO <br />MAINTAIN ASSEMBLY RATING. <br />1 <br />2 <br />3 <br />4 <br />4.4" DIAMETER OR LESS TYPE <br />L COPPER DOMESTIC WATER <br />PIPE, OR 10" DIAMETER <br />LESS CAST IRON WASTE AND <br />VENT PIPE. <br />KEYNOTES: <br />NOTES: <br />KEYNOTES: <br />1. BALL VALVE (TYP). <br />2. UNION (TYP). <br />3. WATER HEATER (TYP). <br />4. P & T RELIEF VALVE -INDIRECT TO NEAREST <br />FLOOR SINK/ DRAIN (TYP). <br />5. DHW OUTLET. <br />6. DCW INLET. <br />NOTES: <br />A. PROVIDE EACH WATER HEATER WITH <br />SEISMIC STRAPS LOCATED 1/3 OF THE <br />WATER HEATER'S HEIGHT FROM THE <br />BOTTOM TO TOP OF THE WATER HEATER. <br />SECURE STRAPS TO WALL. <br />B. PROVIDE CONDENSATE DRAIN IF REQUIRED. <br />ROUTE TO NEAREST FLOOR SINK. <br />C. PROVIDE THERMO WELL AT THE INLET AND <br />OUTLET OF EACH CONNECTION TO <br />EQUIPMENT. <br />2 <br />6 <br />3 <br />4 <br />1 <br />5 <br />KEYNOTES: <br />1. BLENDING VALVE., <br />2. SENSING LINES. <br />3. SAMPLING COCK.THROTTLING GLOBE VALVE. <br />4. UNION (TYP). <br />5. FLOW METER (TYP). <br />6. ISOLATION VALVE. <br />7. HARD WATER LINE. <br />8. MANUAL BYPASS VALVE. NORMALLY <br />CLOSED. <br />9. MANUAL INLET ISOLATION VALVE (TYP). <br />10. CONTROLLER (TYP). <br />11. MANUAL OUTLET ISOLATION VALVE (TYP). <br />12. 4" THICK HOUSKEEPING PAD. <br />13. FLOOR SLAB. <br />7 <br />1 2 <br />11 <br />2 <br />3 <br />4 <br />5 <br />46 <br />8 <br />9 <br />12 <br />13 <br />14 <br />BRINE TANK <br />MINERAL TANK MINERAL TANK <br />KEYNOTES: <br />1. PUMP DISCHARGE -TO WATER HEATER / <br />MIXING VALVE. <br />2. BALL VALVE (TYP). <br />3. CHECK VALVE (TYP). <br />4. CIRC PUMP WITH INTEGRAL TEMPERATURE <br />SENSOR. <br />5. AUTOMATIC AIR VENT (TYP). <br />6. PUMP INLET. <br />7. TEMPERATURE GAUGE. <br />NOTES: <br />A. PUMP TO VARY FLOW TO MAINTAIN <br />SETPOINT RETURN WATER TEMPERATURE. <br />B. PUMPS TO ALTERNATE OPERATION. <br />1 <br />7 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />FLOOR <br />KEYNOTES: <br />1. SPLASH BLOCK. <br />2. COPPER DRAIN THRU WALL. <br />3. REFER TO DRAWINGS FOR CONDENSATE <br />ROUTING. ROUTE ALL CONDENSATE ON <br />WARM SIDE OF INSULATION. <br />4. DRAIN FROM UNIT INTO DRAIN STACK TO <br />TAIL PIECE. <br />5. PTAC. <br />54 <br />2 <br />3 <br />1 <br />2 <br />KEYNOTES: <br />1. AVOID DIRECT INSTALLATION TO PREVENT <br />FOREIGN MATERIAL FROM ENTERING <br />DIRECTLY INTO PRIMER. <br />2. LINE SHUT OFF VALVE. <br />3. UNION CONNECTION. <br />4. TRAP PRIMER VALVE. <br />5. FILTER SCREEN. <br />6. FOUR VIEW HOLES. <br />7. MI-GAP AIR GAP FITTING. <br />8. TRAP PRIMER SHOULD BE MOUNTED ONE <br />FOOT ABOVE THE FINISHED FLOOR FOR <br />EVERY 20 FEET OF PRIMER LINE. <br />9. WATER TRAP. <br />10. SEWER GAS. <br />11. FLOOR DRAIN/ SINK TRAP PRIMER <br />CONNECTION. <br />NOTES: <br />A. APPLIES TO ALL DRAINS/ FLOOR SINKS <br />UNLESS NOTED OTHERWISE. <br />B. DO NOT INSTALL THE TRAP SEAL PRIMERS <br />CLOSER THAN 40' APART WHEN USING THE <br />SAME POTABLE WATER SUPPLY LINE. <br />C. THE DEVICE SHOULD BE LOCATED WITHIN <br />20' OF THE VALVE OR FAUCET FOR <br />OPTIMAL DISCHARGE. <br />NOTES (CONT.): <br />D.INSTALL TRAP PRIMER IN ACCESSIBLE <br />LOCATION. PROVIDE ACCESS PANEL IF <br />NECESSARY. COORDINATE ACCESS PANEL <br />WITH GENERAL CONTRACTOR/ ARCHITECT. <br />E.CONNECT ONLY TO THE BRANCH PIPING OF <br />FIXTURES THAT SEE FREQUENT USE. <br />3 <br />4 <br />1 <br />11 10 <br />9 <br />8 <br />7 <br />6 <br />5 <br />KEYNOTES: <br />1. BALL VALVE (TYP). <br />2. STRAINER (TYP). <br />3. CHECK VALVE (TYP). <br />4. TEMP SENSOR. <br />5. MIXED WATER OUTLET. <br />6. FROM RECIRCULATION PUMPS. <br />7. HOT WATER FROM HOT WATER HEATERS. <br />8. TO HOT WATER SUPPLY. <br />9. COLD WATER INLET. <br />10. ARMSTRONG DVR MIXING VALVE. <br />NOTES: <br />A. INSTALL PER MANUFACTURERS <br />RECOMMENDATIONS. DETAIL FOR <br />REFERENCE ONLY. <br />3 <br />65 <br />89 <br />10 <br />2 <br />4 <br />17 <br />NO SCALEP5.1 <br />VENT THROUGH ROOF1 <br />NO SCALEP5.1 <br />CLEANOUT2 <br />NO SCALEP5.1 <br />WALL CLEANOUT30 1/2"1/4" 1" 2"IF THIS SHEET IS NOT 30"x42", IT IS A REDUCED PRINT - SCALE ACCORDINGLYThis drawing, printed or otherwise, is the copyrighted property of RED Inc Architects . The drawing may not be used, reproduced or copied without the permission of RED Inc Architects.REVISIONS: <br />BA PROJECT #161010CONSTRUCTION DRAWINGS FOR:DATE: <br />DRAWN:LODICHECKED: <br />PLN PROJECT #17077 <br />MARRIOTT #4476 <br />PERMIT #-CALIFORNIAAPN #058-66-012 <br />SHEET TITLE: <br />SHEET NO.: <br />SEAL: <br />CONSULTANT: <br />RED INC ARCHITECTS <br />1217 J STREET, MODESTO, CA 95354 <br />209.522.890030" x 42"JOB NUMBER: <br />THESE PLANS, DRAWINGS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF ENGINEERING <br />SYSTEM SOLUTIONS AND SHALL NOT BE REPRODUCED IN ANY FORM WITHOUT WRITTEN <br />CONSENT. ALL RIGHTS ARE RESERVED. COPYRIGHT 2018 ENGINEERING SYSTEM SOLUTIONS <br />4943 NORTH 29TH EAST, STE A <br />IDAHO FALLS, IDAHO 83401 <br />PHONE: (208) 552-9874 <br />ENGINEERING SYSTEM SOLUTIONS <br />STRUCTURAL • MEP • BUILDING COMMISSIONING <br />www.es2eng.com <br />BUILDING RELATIONSHIPS <br />EXCEEDING EXPECTATIONS <br />17.1019 <br />This drawing, printed or otherwise, is the copyrighted property of Burkett Architect PC . The drawing may not be used, reproduced or copied without the permission of Burkett Architect PCIF THIS SHEET IS NOT 30"x42", IT IS A REDUCED PRINT -SCALE ACCORDINGLY2"1"1/4"1/2"030" x 42"4/12/19 <br />P5.1 <br />PLUMBING DETAILS <br />ACS <br />HS <br />NO SCALEP5.1 <br />FIRESTOP FOR PIPING THROUGH GYPSUM WALLS4 <br />NO SCALEP5.1 <br />PIPING PENETRATION AT ONE HOUR RATED WALL ASSEMBLY6 <br />NO SCALEP5.1 <br />PIPING PENETRATION AT ONE HOUR RTD FLR/CLG ASSEMBLY7 <br />NO SCALEP5.1 <br />BTU WATER HEATER CONNECTIONS (3 WATER HEATERS)9 <br />NO SCALEP5.1 <br />WATER SOFTENER DETAIL10 <br />NO SCALEP5.1 <br />DUAL HOTWATER RECIRC PUMP5 <br />NO SCALEP5.1 <br />CONDENSATE DRAIN STACK11 <br />NO SCALEP5.1 <br />PRESSURE DROP ACTIVATED TRAP PRIMER12 <br />NO SCALEP5.1 <br />DRV 508 <br />E <br />IN <br />ARSESIOFNO <br />L <br />OIFCALOF <br />R <br />D <br />SIERGERETT <br />S <br />A <br />ET <br />P <br />EXP. 9-30-18 <br />M37119 NREEIGN <br />AMECHA N I C A LHU G H STAIN. <br />G <br />E <br />R04/12/2019