My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROCKY
>
262
>
1600 - Food Program
>
PR0545763
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 6:12:58 PM
Creation date
8/25/2020 2:50:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545763
PE
1624
FACILITY_ID
FA0025909
FACILITY_NAME
FAIRFIELD INN & SUITES LODI
STREET_NUMBER
262
STREET_NAME
ROCKY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
262 ROCKY LN
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VI <br /> GEILING DIMENSION LEC END GENERAL NOTES THIS SHEET REFLEGTED GE I L I NC KEYNOTES <br /> I. CEILING HEIGHT/FINISH TAG - SEE LEGEND BELOW . U <br /> CENTER FIXTURE IN SPACE - I. ALL LIGHTS TO ACTIVATE TO FULL BRIGHT 2. CENTER GEILING TILE IN CORRIDOR. SEE GEILING . <br /> O CENTER THE FIXTURE IN THROUGH THE DIMMING PANEL DURING DETAILS FOR ADDITIONAL INFORMATION <br /> FOR TYPICAL GEILING DETAILS - SEE SHEET AD8 SPACE IDENTIFIED BY EMERGENCY ALARM ACTIVATION. <br /> DIAC70NAL LINE. 3. 0/8" THICK ) EXTERIOR GEMENT PLASTER <br /> iv 2 BEY-IN / SUSPENDED GEILIN&INSTALLED BELOWRATEDYSTEMS AiRE TO DINESBAS REQUIRED - SPROVIDE EXP ELEIVOATIONS <br /> ASSEMBLIES. J ��yy <br /> ALIGN FIXTURES 4. EMERGENCY FLOOD LIGHTS WITH BATTERY BACKUP L.L <br /> - ALIGN FIXTURES ALONG - SEE ELECTRICAL PLANS <br /> o PROVIDE AGGESS PANELS AT LOCATIONS <br /> �REQUIRIN6 AGGESS CENTERLINE SHOWN 5. EXIT SIGN WITH BATTERY BACKUP - TYPICAL - SEE <br /> ELECTRICAL PLAN FOR ADDITIONAL INFORMATION- QED INC A-RGHITEGTS <br /> PROVIDE TACTILE SIGNS AT ALL DOORS WITH EXIT 1211 J STREET,MODESTO,GA 65354 <br /> z CENTER OVER SIGNS AND FLOOR LEVEL EXIT SIGNS 20a.522.8g00 <br /> Q - CENTER FIXTURE OVER <br /> y GENTERLINE OF ADJACENT 6. MECHANICAL EQUIPMENT - SEE MECHANICAL <br /> O SEE SHEETS AOII FOR WALL CONSTRUCTION DRAWINGS SEAL: <br /> ASSEMBLIES AND PENETRATION <br /> Q DETAILS -7. EXHAUST FAN LOCATION - SEE MECHANICAL <br /> J S <br /> AV41NOS - COORDINATE VENT LOCATIONS WITH ip ARCy/� <br /> N5. LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS i��P\O� BUR�FjJ CJ <br /> O <br /> G. -ROOF ACCESS LADDER AND HATCH- SEE DETAIL II 17� <br /> A22I d 12/AD6 3 <br /> REN. <br /> Q �J 03-31-21 <br /> p I �TFOFCA\-\FO <br /> w 1 <br /> 1 2 3 4 5 6 7 8 9 10 11 11.. 12 13 14 15 16 17 18 8. 19 0 <br /> N <br /> CONSULTANT: <br /> O <br /> O <br /> GEILING NOTES: <br /> N I. ALL FURRDOWN AREAS TO BE CONSTRUCTED OF <br /> NONCOMBUSTIBLE MATERIALS. VERIFY <br /> W MECHANICAL DUCT CLEARANCES WITH <br /> lu <br /> MECHANICAL CONTRACTOR PRIOR TO <br /> — — — — — — L — — — — — — — — — — — — L CONSTRUGTING FURROOWNS. <br /> 2. ELEVATOR EQUIPMENT-ROOM IS TO BE <br /> COMPLETELY I-HR PROTECTED. SEE SHEET AOII <br /> FOR-RATED FLOOR/ GEILING ASSEMBLIES. <br /> 3. SEE ELECTRICAL d MECHANICAL PLANS FOR <br /> FIXTURE SCHEDULES 8 LOCATIONS OF EMERGENCY <br /> LIGHTS, EXIT LIGHTS AND A/G-REGISTERS. <br /> 4. ALL GEILING HEIGHTS A-RE MINIMUM CLEAR AND <br /> 2 MUST BE MAINTAINED. IF ABLE TO-RAISE DRYWALL <br /> A231 GEILING (9 PUBLIC AREAS, NOTIFY ARCHITECT AND <br /> OENRGRIOR TO CONSTRUCTION OF DROPPED <br /> EILI <br /> 1 5. GEILING AT CUPBOARD SHALL HAVE A DURABLE, <br /> 1 SMOOTH, NON-ABSORBENT AND WASHABLE <br /> SURFACE. <br /> 6. SUSPENDED CEILINGS SHALL MEET CRITERIA PER <br /> APPLICABLE CODES AND HAVE A MINIMUM NOISE <br /> -REDUCTION COEFFICIENT (NRG) OF 0.8. <br /> O <br /> 1. WHEN INSTALLING GEILING MOUNTED EXIT SIGNAGE <br /> - GENERAL CONTRACTOR TO VERIFY LINE OF <br /> SIGHT IS MAINTAINED AND NOT OBSCURED BY <br /> FURRED GEILING FIXTURES - NOTIFY ARCHITECT IN <br /> WRITING OF ANY CONFLICTS PRIOR TO MH o SMTES <br /> INSTALLATION BY <br /> MARM <br /> TT <br /> O 4 — — — — — 2 — — — — — — — — — — — — — — 2 — I — — 8. GENERAL CONTRACTOR TO OVERSEE O <br /> A221 — — — — — — — — — — — — O — O — — COORDINATION OF ALL TRADES VERIFY <br /> EXACT LOCATION OF DUCTS, CONDUITS, LIGHTS, <br /> REGISTERS, EOUIPMENT TRAYS, PLUMBING, WASTE, <br /> AND FIRE SPRINKLER LINES. NOTIFY ARCHITECT IN <br /> WRITING OF ANY CONFLICTS, <br /> I I I I <br /> 1 1 I 1 G. WALL SGONGE FIXTURES LOCATED IN CORRIDORS <br /> © — — — — — — — — — — — — — — OR ALONG AGGESSIBLE PATH OF TRAVEL WHICH <br /> OJ GT 4" OR MORE FROM WALL SURFAGE MUST <br /> BE MOUNTED SUCH THAT THE HEIGHT FROM FINISH <br /> FLOOR IS 80" OR MORE TO THE BOTTOM OF ANY <br /> PROJECTION ON THE FIXTURE - VERIFY ROUGH-IN <br /> L - — — — HEIGHT WITH EXACT FIXTURE PRIOR TO <br /> INSTALLATION. E77774 < <br /> EQ. EQ. n n n Z <br /> O — — 10. ALL SPRINKLER HEAD PENETRATIONS THROUGH u <br /> SUSPENDED CEILINGS ARE TO HAVE FLEXIBLE <br /> HOSE CONNECTIONS OR SWING JOINTS WHICH GAN <br /> 0 - REFER TO ENLARGED ACGOMMODATE A I" MINIMUM HORIZONTAL J <br /> O GUESTROOM GEILING MOVEMENT IN ANY DIRECTION. SEE FIRE • Q <br /> REFER TO ENLARGED PLANS FOR CEILING SPRINKLER DRAWINGS (DEFERRED SUBMITTAL) <br /> O I INFORMATION FOR THIS <br /> GUESTROOM GEILING 4� MAX A AREA (HATCHED) II. USE DENS-SHIELD (OR APPROVED EQUAL) AT ALL <br /> PLANS FOR GEILING <br /> REFER TO ENLARGED WET LOCATIONS OR WHERE MOISTURE RE515TANT <br /> INFORMATION FOR THIS GUESTROOM GEILING <br /> GYP. 130. 15 SPECIFIED <br /> — I INS 1 AREA (HATCHED) PLANS FOR GEILING <br /> 400 GEILING INFORMATION FOR THIS 12. FIRE SPRINKLER HEADS TO BE CENTER OF <br /> Ni AREA (HATGHED) ACOUSTIC GEILING TILE AT ALL PUBLIC, AGGESS n n n <br /> L AREAS. u <br /> v <br /> � II II T II G <br /> s 0 <br /> L <br /> v G,_E O <br /> TYP. O MAX A <br /> _8„A I LuIF4-0-0-]GE I L I NO <br /> 0 III = 12 O 8'-O"D O O O <br /> O 400 GEILING 8'-O"A H13 <br /> A 5 404 GEILING l'-8'A 12 TYP. A40 TY A -L2 l'-8"A 8, O,A 5 �'-8"A -7 7'-8"A 404. GEILING 1 _8„A <br /> O ' - — <br /> 8-0D <br /> O O O O O O O O O <br /> O <br /> O O I GE I L I NC LEGEND <br /> l l-8A i 2 - 5 0 <br /> Q <br /> - <br /> - - RECESSED FIXTURE <br /> G'-3"A <br /> sELI <br /> 400 GEILING 400 GEILING TYP. El <br /> 2' x 2'-RECE55ED FIXTURE ks) <br /> O MAX A <br /> No, z <br /> 2' x 4'-RECESSED FIXTURE <br /> 3 C VIII K <br /> - SII o 4" ST-RIP-REGESSED LIGHTING FIXTURE n <br /> O <br /> Z � <br /> o -RECESSED LIGHTING FIXTURE O <br /> 1 REFER TO ENL <br /> 75ARGED — �GUESTROOM GEILING )C( G PENDANT LIGHTINFIXTURE 0 <br /> u <br /> 1 PLANS FOR GEILING ( a <br /> v INFORMATION FOR THIS b WALL MOUNTED LIGHT FIXTURE <br /> O , fREFER TO ENLARGED AREA (HATCHED) O n n � C) <br /> GUESTROOM GEILING O SPEAKER01 u <br /> v <br /> N PLANS FOR GEILING EXIT <br /> INFORMATION FOR THIS �® EXIT LIGHT <br /> AREA (HATGHED) <br /> DECORATIVE WALL SCONCE <br /> N O — — — — —� <br /> Zz_ — — — — — — PREVISIONS: <br /> O <br /> El MECHANICAL EXHAUST GRILLE <br /> I BLDG DEPT. 10 12 I <br /> O O 2X2 MEGHANICAL-RETURN GRILLE 2 E31_06 <br /> 10 11 <br /> 3 MARRIOTT <br /> 03/20/1ci <br /> ® <br /> 4 OWNER-REV. O /20/1 G <br /> 12X12 MECHANICAL SUPPLY GRILLE 5 ASI #002 03/20/IG <br /> A231 12X12 MECHANIGAL-RETURN GRILLE <br /> v <br /> SD SMOKE DETECTOR <br /> BA PROJEGT # 161010 <br /> O — — — — — — — — — — — — — — — — — — — — — — — — — — PROVIDE EMERGENCY LIGHTING ASPLN PROJECT # I-101-1 <br /> -REQUIRED BY LOCAL CODE <br /> MARRIOTT # 44-76 <br /> D <br /> EXTERIOR LIGHTING <br /> PERMIT # - <br /> DECORATIVE PENDANT APN # 0586-012-6 <br /> N <br /> Q <br /> EM <br /> ELECTRICAL PLASN <br /> GEILING FINISH LEGEND <br /> DATE: 11/13/2018 <br /> GEILING HEIGHT DR <br /> p`wN` ' <br /> CEILING FINISH CHEGKED: D. BURKETT <br /> s <br /> O <br /> O A. PRIMED d PAINTED GYPSUM BOARD SHEET TITLE: <br /> s <br /> B. PRIMED & PAINTED GYPSUM BOARD - MOISTURE <br /> -RESISTANT OVERALL THIRD <br /> 3 <br /> 1 2 3 4 5 6 7 8 9 10 11 1. 12 13 14 15 16 17 18 8. 19 O <br /> G. NOT USED LEVEL REFLECTED <br /> p) D. 2x2 LAY-IN GLC. GRID SYSTEM SUSPENDED CEILING PLAN <br /> FROM STRUCT. INFILLED W/ ACOUSTICAL GLC. <br /> O TILE -SEE FINISH SCHEDULE <br /> O <br /> E. 2x2 LAY-IN GLC. GRID SYSTEM SUSPENDED <br /> N <br /> FROM STRUCT. INFILLED W/ WASHABLE GLC. TILE <br /> -SEE FINISH SCHEDULE <br /> F. STUCCO SYSTEM (LIGHT SAND) <br /> 3 <br /> OVERALL THIRD LEVEL REFLEGTED GEILINO PLAN <br /> G. 2x4 LAPIN GLC. GRID SYSTEM SUSPENDED FROM SHEET O.: <br /> STRUGT. INFILLED W/ WASHABLE GLC. TILE -SEE <br /> SCALE: 1/8” = 1'-0" <br /> FINISH SCHEDULE <br /> H. ARMSTRONG WOODWORKS LINEAR 6460WI 6" <br /> PLANKS, COLOR: ECHO WALNUT - SEE DETAILS <br /> PLAN NORTH SHEET A405 <br />
The URL can be used to link to this page
Your browser does not support the video tag.