My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
ROCKY
>
262
>
1600 - Food Program
>
PR0545763
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 6:12:58 PM
Creation date
8/25/2020 2:50:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0545763
PE
1624
FACILITY_ID
FA0025909
FACILITY_NAME
FAIRFIELD INN & SUITES LODI
STREET_NUMBER
262
STREET_NAME
ROCKY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
262 ROCKY LN
P_LOCATION
02
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
164
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N ��//'�� <br /> V/ <br /> NINDON GENERAL NOTES: ~ <br /> I. -REFER TO SPECIFICATIONS FOR ADDITIONAL GLAZING • <br /> ALL VENTS TYPICAL: -REQUIREMENTS. W <br /> ALUMINUM VENT WITH STORM PROOF BLADES. <br /> KYNAR PAINTED TO MATCH ADJACENT WALL 2. GLAZING IN THE FOLLOWING LOCATIONS SHOULD BE OF — <br /> FINISH. VERIFY SIZE WITH MECHANICAL SAFETY GLAZING MATERIAL IN ACCORDANCE W/ LOCAL <br /> PLANS CODE: <br /> N v' ` <br /> A.FIXED d SLIDING PANELS OF SLIDING DOOR A55EMBLE5 d n/ <br /> PANELS IN SWINGING DOORS LL <br /> 14ol6'-O" 14 6'-O" <br /> EQ EQ EQ EQ SEE MEC-H. PLANS B.WINDOWS WITHIN 24" OF DOOR5 IN ANY POSITION, WHERE <br /> o I4 6 O AD5 AD5 THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS RED INC ARCHITECTS <br /> lo THAN 60 INCHES ABOVE THE WALKING SURFACE. <br /> AD5 EQ EQ = 1211 J STREET,MODESTO,GA 95354 <br /> z w G.INDIVIDUAL FIXED OR STOP (WALL OR CLOSER MOUNTED) 209.522.89oo <br /> Lu PANEL, OTHER THAN THOSE LOCATIONS DESCRIBED <br /> N O ABOVE, THAT MEET ALL OF THE FOLLOWING CONDITIONS: <br /> y W 1n <br /> 0 O z i) EXPOSED AREA OF AN INDIVIDUAL PANE 15 GREATER SEAL: <br /> N ~ - THAN G 50.FT. <br /> a _ -1 <br /> JO 15 O O v ii) EXPOSED BOTTOM EDGE IS LESS THAN I8" ABOVE THE SED ARCy/� <br /> Q (V cv d) dJ 1 R <br /> LL = FLOOR Q,� E.BU F <br /> N r r AD5 z iii) EXPOSED TOP EDGE IS GREATER THAN 36" ABOVE THE <br /> Q LL FLOOR <br /> z 3�I <br /> ry LEZ iv) ONE OR MORE WALKING SURFACES A-RE WITHIN 36" <br /> HORIZONTALLY OF THE PLANE OF THE GLAZING. REN. <br /> 03-31-21 �P <br /> I6 16 3 ALL 5T-ROOM WWA- <br /> INDOS RE OPERABLE WITH 4" MAX <br /> OPE NC6 �TFpFCAL�F�� <br /> AD5 AD5 4. ALL WINDOW SILLS PER MARRIOTT FAIRFIELD INN 8 SUITES <br /> OB OOPERABLE WINDOW W/ GO OPERABLE WINDOW OD NOT USED EO LOUVERED VENT INTERIOR FINISH 5PECIFI6ATION5 OPERABLE WINDOW W/ BUILT-IN PTAG RILL EVENT GENTER 4 OFFIGE GENERAL GONTRAGTOR TO <br /> BUILT-IN PTAG GRILL BUILT-IN 5. MANUFACTURER IS-REQUIRED TO VERIFY ALL FIELD <br /> ~ 5TG=3G 5TG=3G 4 VERIFY SIZE AND LOCATION WITH DIMENSIONS PRIOR TO FABRICATION 8 INSULATION OF <br /> TYPIGAL IST TYPIGAL GUESTROOM GUESTROOM FLOOR LAUNDRY CONSULTANT <br /> � WINDOWS <br /> O GON5ULTANT: <br /> X <br /> Cb. WINDOW FRAMES SHALL BE� YBH0JAN' M-85 OR <br /> m <br /> APPROVED EQUAL. <br /> O '7. WINDOWS SHALL MEET OR EXCEED LOCAL ENERGY CODES. <br /> II'-II 1/2" e x. II'-II 1/2 e <br /> PROVIDE 0.25 U VALUE AND 0.20 SHGG GLAZING AS <br /> -REQUIRED BY TITLE 24 ENERGY-REPORT <br /> 2'-4 1/2" 5'-8" 2-4 1/2" 2'-4 1/2" 5'-8" 2'-4 1/2" Il 8'-5" 12'-4" e. <br /> AD5 EQ EQ EQ AD5 EO EQ IdeEQ 8.ALL WINDOWS SHALL HAVE A MINIMUM 5TG RATING OF 3q. <br /> Nell Ti ell CONTRACTOR TO VERIFY FOR LOCATIONS, BRAND <br /> irm m REQUIREMENTS AND WITH OWNER. <br /> Il Il p 9. PTAG GRILLS ARE TO BE INTEC-,RAL TO THE WINDOW, NO <br /> LL A05 AD5 SUBSTITUTIONS WILL BE ALLOWED. <br /> 3 4IO.EXTERIOR WINDOWS SHALL BE TESTED AND LABELED A5 <br /> AD5 AD5 18 18 CONFORMING TO AAMA/WDMA/GSAIOI/1.5.2/A440. <br /> UI <br /> AD5 AD5 II. WINDOW FLASHING TO BE INSTALLED PER DETAIL 23/AD5 <br /> l � � _ -N6' l � � _ -N6' <br /> AD5 DOOR TYPE A AD5 DOOR YPE A i 7 p d) 17 p dJ 12.LOUVERS FOR THRU-WALL HVAC UNITS IN GUESTROOMS <br /> r r AD5 r AD5 r MUST BE FURNISHED BY THE WINDOW MANUFACTURER AND <br /> MUST BE ALUMINUM, A-RGHITEGTURAL-STYLE WITH A FINISH <br /> TO MATCH THE WINDOW SECTIONS. THESE ARCHITECTURAL5 5 LOUVERS MUST BE AN INTEGRAL PART OF THE WINDOW <br /> AD5BA BA AD5 BA 3A SYSTEM (ONE-PIECE FACTORY ASSEMBLED UNIT). LOUVERS <br /> T T T T T T TIL— T TT T T T T MUST MEET THE FREE AR-REQUIREMENTS OF THE <br /> THRU-WALL UNIT SELECTED. <br /> 13.GENERAL CONTRACTOR 15-REQUIRED TO VERIFY ALL <br /> AD5 AD5 AD5 AD5 DOOR, WINDOW 8 PTAG INSTALLATIONS A-RE PROTECTED <br /> O SLIDING ENTRY SYSTEM O SLIDING ENTRY SYSTEM O FIXED STOREFRONT O FIXED STOREFRONT FROM OTHER TRADES DURING CONSTRUCTION - DAMAGED <br /> UNITS TO BE-REPAIRED OR-REPLACED AT THE p <br /> EXTERIOR VESTIBULE INTERIOR VESTIBULE VESTIBULE LOUNGE CONTRACTORS EXPENSE TO THE SATISFACTION OF THE <br /> m n R d <br /> OWNER. ��pp ��pp pp np 22 <br /> IIV UV o SluJ � TES <br /> A MINIMUM ENERGY/AGOUST I G BY M Q R M 0 T T <br /> REQUIREMENTS FOR GLAZ I NC <br /> EQ w 6'-0" EQ10'-0" FIXED WINDOWS: <br /> 6'-6" Il Il Il <br /> I7 3'-O" EQ EQ EQ DUAL PANE /METAL FRAMED /LOW-E GLA55 UNITS TO MEET <br /> AD5 —fl —EQ EQ AD5 AD5 AD5 OR EXCEED: <br /> ell 'I <br /> 0.23 U-FAGTOR <br /> w ell 0.20 SHGG MINIMUM OUTDOOR-INDOOR TRANSMISSION <br /> - r GLASS (STC)=39 <br /> III <br /> T T <br /> Sic <br /> 1- GLASS DOORS: <br /> 18 IS AD5 r DUAL PANE /METAL FRAMED /GLEAR GLASS UNITS MEET OR <br /> AD5 EXCEED: Q <br /> 0.20 U-FAGTOR <br /> 6 0.23 SHGG <br /> 11 13 N dJ AD5 dJ Q MINIMUM OUTDOOR-INDOOR TRANSMISSION GLASS (STC)=3G <br /> AD5 r AD5 / \ / \ r IG <br /> AD5 PTAG UNITS - MINIMUM AGOU5TIGAL-REQUIREMENT5J <br /> 1-7 ALL PTAG UNITS ARE-REQUIRED TO MEET OR EXCEED A <br /> AD5 MINIMUM OUTDOOR-INDOOR TRANSMISSION GLA55 (OITG) = 23 <br /> T T T T T <br /> MINIMUM SOUND TRANSMISSION GLA55 OF (5T6) = 28 <br /> MINIMUM ROUGH OPENING SEE MANUFACTURER SPECIFICATIONS. <br /> IG IG IG r��//nil <br /> AD5 AD5 AD5 <br /> si O FIXED STOREFRONT O FIXED STOREFRONT O FIXED STOREFRONT O FIXED STOREFRONT TYPICAL GUESTROOM NINDON NOTES: IM <br /> LOUNGE BREAKFAST BREAKFAST BREAKFAST <br /> I. DUAL PANE ALUMINUM WINDOWS (TRAGO TR-6400). OR <br /> s APPROVED EQUAL. MANUFACTURERS TO SUBMIT SHOP <br /> v DRAWINGS AND SAMPLES FOR APPROVAL PRIOR TO <br /> FABRICATION. <br /> v 2. ALL OPENABLE EXTERIOR WINDOWS SHALL BE SCREENED <br /> WITH NOT LESS THAN SIXTEEN (I(b) MESH PER 5QUARE INCH <br /> A4 SCREENING <br /> 3. OPERABLE WINDOWS, WHEN-REQUIRED, MUST HAVE A <br /> GHILDPROOF LOCKING DEVICE APPROVED BY MARRIOT <br /> 20'-7" 15'-8" FAIRFIELD INN d SUITES AND A-RE NOT ALLOWED TO OPEN o <br /> 5'-11" MORE THAN 4"/102 MM <br /> O I7 5 1/2" 5 1/2" 5 1/2" I7 0" 10" 21 <br /> AD5 EQ EQ EQ EQ AD5 EQ EQ EQ AD5 2'-5" 3'-0" <br /> 0 4'-10" GLAZING LEGEND: Q <br /> a <br /> 22 3'-0" 1'-4" <br /> AD4 <br /> SYMBOL: COLOR: DESG-RIPTION: u <br /> p) 20 0 <br /> T CLEAR TEMPERED <br /> s AD4 1l %% INSULATED 5/8" GLA55 <br /> LL <br /> BA CLEAR BREAKAWAY PANELS � <br /> O I l cp 1_ c0 2I <br /> AD5 c0 AP 5 c0 X\ d� 13 c� Z n (( I <br /> AD5 K lug <br /> AD5 / \ r < o O <br /> N nn <br /> 21 20 Z <br /> vAD4 T AD5 T <br /> � T T T T T T <br /> IG IG 18 IG � Q z�0 — <br /> AD5 AD5 AD4 AD5 Z 75 <br /> C) <br /> OFIXED STOREFRONT WRAP COLUMNS WITH BREAK O FIXED STOREFRONT WRAP COLUMNS WITH BREAK O FIXED STOREFRONT O FIXED STOREFRONT O <br /> FITNESS METAL - FINISH TO MATCH FITNESS METAL - FINISH TO MATCH INTERIOR FITNESS CORRIDOR SIDELIGHT <br /> STOREFRONT SYSTEM STOREFRONT SYSTEM <br /> 7 <br /> N <br /> u� <br /> 4J <br /> REVISIONS: <br /> 0 <br /> I BLDG DEPT. 101121185 <br /> I, 2 D6 DEPT. O <br /> 3 MARRIOTT 03/20/1 q <br /> AD5 14 6' O.. <br /> AD5 EG EG 5 OASIN 002EV 03/20/IG <br /> N <br /> s <br /> BA <br /> f— - <br /> cv <br /> v - � <br /> 161010 <br /> r N PROD EGTEGT # <br /> P # 1-70 <br /> Tll MARRIOTT # 4476 <br /> D <br /> 11.1 <br /> IG <br /> PERMIT # - <br /> O AD4 <br /> APN # 058-66-012 <br /> -R FIXED STOREFRONT <br /> UPPER LEVEL GORRIDOR O OPERABLE WINDOW <br /> C) STG=3q <br /> TYPIGAL HOUSEKEEPING DATE: 11/13/2018 <br /> N <br /> DRAWN: G.OUAJARDO <br /> CHECKED: D. BURKETT <br /> S <br /> Q <br /> O <br /> v <br /> SHEET TITLE: <br /> A WINDOW SCHEDULE <br /> .3 <br /> NOTE: <br /> s� WINDOW AND STOREFRONT MANUFACTURERS TO <br /> O SUBMIT SHOP DRAWINGS AND SAMPLES FOR <br /> APPROVAL PRIOR TO FABRICATION - TYPICAL <br /> O <br /> GLASS IN LOCATIONS SUBJECT TO HUMAN IMPACT <br /> SHALL BE TEMPERED PER GBG 2406 <br /> STOREFRONT FINISH: WHITE <br /> 1/4" CLEAR GLAZING - TYPIGAL AT INTERIOR UNLESS SHEET NO.: <br /> 3 OTHERWISE NOTED - V15TAWA-L FG-1000 SERIES <br /> O <br /> 1" DUAL PANE INSULATED GLAZING - VI5TAWALL <br /> s SERIES FG-3000 CENTER 5ET - TYPICAL AT <br /> EXTERIOR UNLESS OTHERWISE NOTED A801 <br />
The URL can be used to link to this page
Your browser does not support the video tag.