Laserfiche WebLink
N ,�//�� <br /> /47_� <br /> v/ <br /> 1 AGO 2 <br /> STAIR KEYNOTES: U <br /> I. HANDRAIL - VERIFY OWNER�REOUFREMENTS - INSTALL NOT LESS THAN 34" • LU <br /> OR MORE THAN 36" ABOVE NOSING OR TREADS PER GBG --RETURN TO <br /> 5 1/2" q'-1 3/4" 2 3/4" WALL - HANDRAIL SHALL EXTEND A MIN. OF 12" BEYOND THE TOP NOSING <br /> AND 12" PLUS THE TREAD WIDTH BEYOND THE BOTTOM NOSING - SEE STAIR <br /> STANDPIPE DETAILS I THROUGH 8/AD1 T <br /> 3 LOCATION TYP. 2 <br /> N % 2. LOCATION OF KNOX BOX - MOUNT ADJACENT TO STAIR ENTRY IN A U <br /> E LOCATION VISIBLE TO FIRE DEPARTMENT - VERIFY LOCATION WITH FIRE fV <br /> D <br /> MARSHALL- SEE DETAIL 12/ADI Q <br /> 0 <br /> ------- RED INC, A-RGHITEGTS <br /> J <br /> 1211 J STREET,MODESTO,GA 95354 <br /> N 209.522.8900 <br /> z 4'-4" q 3/4" 4'-2" m <br /> 6 <br /> o STAIR SIGNAGE REG: SEAL: <br /> r 1023.x.1 SIGNAGE REQUIREMENTS. STAIRWAY IDENTIFICATION SIGNS SHALL COMPLY <br /> Q - WITH ALL OF THE FOLLOWINO-REGUIREMENT5: <br /> LLI111 = II = I. THE SIGNS SHALL BE A MINIMUM SIZE OF 18 INCHES (451 BY 12 INCHES (305MM). �SE�ARCN/T� <br /> �n� 311 2. THE LETTERS DESIGNATING THE IDENTIFICATION OF THE STAIR ENCLOSURE, �DE.Bl1Rk (� <br /> SUCH AS STAIR NO. I OR WEST STAIR, SHALL BE PLACED AT THE TOP OF THE <br /> SIGN AND SHALL BE A MINIMUM OF 11/2 INCHES (38 MM) IN HEIGHT BLOCK <br /> z U 3 LETTERING WITH 1/4-INCH (6 MM) STROKES. 3G� <br /> 3. THE NUMBER DESIGNATING THE FLOOR LEVEL SHALL BE A MINIMUM OF 5 <br /> - 3511 3111 INCHES (121 MM) IN HEIGHT WITH 3/4-INCH (Iq MM) STROKES AND LOCATED IN <br /> w PREGEOING THE FLOOR LEVEL. BASEMENT LEVELS SHALL HAVE THE LETTER <br /> m - 31 III v THE CENTER OF THE THE MEZZANINE LEVELS SHALL HAVE THE LETTER "M^ q REN. O <br /> 2G m "B" PRECEDING THE FLOOR NUMBER. TF 03-31-2I\� �P <br /> 4• OTHER LETTERING AND NUMBERS SHALL BE A MINIMUM OF I INCH (25 MM) IN OFCA�- <br /> cV r 3 38 O HEIGHT. <br /> 5. THE STAIRWAY'S UPPER TERMINUS, SUCH AS ROOF ACCESS OR NO ROOF <br /> 3q 2l7 r ' ACCESS, SHALL BE PLACED UNDER THE STAIRWAY IDENTIFICATION IN <br /> 40 2611 I-INCH-HIGH (25 BLOCK LETTERING WITH 1/4-INGH (6 MM) STROKES. <br /> 6. THE LOWER AND UPPER TERMINUS OF THE STAIRWAY SHALL BE PLACED AT <br /> N 41 III 2 THE BOTTOM OF THE SIGN IN I-INGH-HIGH (25 MM) BLOCK LETTERING WITH <br /> 1/4-INGH (6 MM) STROKES. <br /> O CONSULTANT: <br /> x <br /> ON 42 1• CHARACTERS AND THEIR BAGKCROUND SHALL HAVE A NONGLARE FINISH. <br /> O - CHARACTERS SHALL CONTRAST WITH THEIR BAGKCROUND, WITH EITHER LIGHT <br /> CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT <br /> BACKGROUND. <br /> 106 FLOOR 8. WHERE SIGNS-REQUIRED BY SECTION 10236 A-RE INSTALLED IN THE INTERIOR <br /> EXIT STAIRWAYS AND-RAMPS OF BUILDINGS 5UBJEGT TO SECTION 1025, THE <br /> S AFR #I 101 LANDING SIGNS SHALL BE MADE OF THE SAME MATERIALS AS-REGUIRED BY SECTION <br /> w ST3.I r- 1025.4. <br /> LLI <br /> i r <br /> IOC STAIR NOSING <br /> � 202 BASE <br /> r <br /> Q 305 HANDRAILS SEE STAIR SIGNAGE DETAIL 21/AD2 <br /> H 3 5 305 DOOR TRIM <br /> N 305 WALL <br /> STAIR NOTES: <br /> O I. COMPLETELY FINISH STAIR INTERIORS (FLOOR, BASE, LANDINGS, WALLS, AND <br /> GE I L I NGS. <br /> 2. PROVIDE CARPET AND CARPET BASE THROUGHOUT. ONLY THE FLOOR LEVEL <br /> STAIR LANDINGS RECEIVE PADDING. TREADS AND-RISERS DO NOT <br /> 1'-11" 3. STAIR N051NG5 TO BE RUBBER. <br /> 4. PAINT ANY EXPOSED FIREYZ15ER/STANDPIPES IN STAIRWELLS <br /> 3'-II I/4" 5'-8" 5. PROVIDE FULL HEIGHT CORNER GUARDS AT ALL OUTSIDE CORNERS TO MATCH <br /> WALL COLOR <br /> 6. PROVIDE LEVEL 3 MEDIUM TEXTURE FINISH AT GEILING/UNDER5IDE5 OF STAIRS <br /> TN I RD L���L �NL�RCC�D STS I R PLAN <br /> O <br /> 4 <br /> O AGO 2 <br /> 5 1/2" W-1 3/4" 1 if IJ"ll A R USS O T T <br /> STANDPIPE <br /> 3 LOCATION TYP. <br /> E II II <br /> T.O. PARAPET <br /> 36'-6" <br /> -------- <br /> T.O.�ROOF SLOPE 1/4" 12 � 4' 211 q 3ML," 4'-2" m <br /> VARIES <br /> �� r _Q <br /> - <br /> PHI <br /> Z <br /> T.O. FINISH FLOOR #4 T.O. PLATE: <br /> >x 402 G 402_771 1 <br /> 3 31 <br /> > TYP. OF 3 �H <br /> m 311111 2G w <br /> IM <br /> II S4II 21 - <br /> 305 % 2 0 <br /> �O 305 411111 2 <br /> <sJ 42 UP = <br /> > 1 - 106 FLOOR (J <br /> W IOl LANDING <br /> (1� <br /> STAFR #I IOq STAIR NOSING <br /> O 305 m T2.1 m 202 BASE <br /> m <br /> •� dj r ;-� � 305 HANDRAILS � a <br /> T.O. FINISH FLOOR #3lul T.O. FINIS FLOOR #3 _ Q 305 DOOR TRIM <br /> 23'-G" <br /> \/ WALL <br /> 3 5 1 305 [ o <br /> 1 C� <br /> LL <br /> 4 <br /> I <br /> O <br /> 3 II � � ���` ) AD1 <br /> p) 202 10-7 O <br /> C) <br /> m 3 <br /> F3-0-51 Z <br /> v X Q <br /> O � X ADl T.O. LAND NG #2 H <br /> O 305 w SEGOND LEVEL ENLARGED STAIR PLAN Cil <br /> 6 - SGALE: 1/4" = 1'-0" Q Q <br /> O d_J �� 0 <br /> � 3 <br /> 4 SYMBOL LEGEND <br /> AGO <br /> A INDICATES ACGESSIBLE GUESTROOM - SEE <br /> IOC O 2 W1 <br /> ENLARGED GUESTROOM PLANS A301, A302, <br /> A303, A305 - SEE TYPICAL AG6E551BILITY <br /> 106 202 305 <br /> 1 2 3/4 DETAILS AND NOTES ON SHEETS AD2 8 AD3 <br /> 4) 5 1/2" q'-1 3/4" <br /> T.O. STANDPIPE -REVISIONS: <br /> O <br /> T.O. FINISH FLOOR 2 FINIS FLOOR 2 <br /> LOCATION TYP. <br /> - 13'-1 3/4" T D T <br /> s � SEE ENLARGED GUESTROOM PLANS A301, I BLDG DEPT. 10/12/18 <br /> A302, A303, A305, 2 BLDG DEPT. 10/31/18 <br /> 6 - 4'-2" q 3/4" 4 X12„ WINDOW TAG - SEE WINDOW SCHEDULE ON <br /> v m 5 AASIN 002ER E 03/20/ICI <br /> � 10 305 FRO5 w 1033A: <br /> p� 4 \ = ODOOR A801- SEE DOOR SCHEDULE ON SHEET <br /> A800 <br /> \\ 2 23 F_� 12 <br /> \ \ _ AP-7 I III SHELET AOI TAG - SEE WALL ASSEMBLY <br /> \ 101 141111 3 # <br /> ��Ln10 ➢ ��G�� ➢ �/ _ 15 III G PLN PROBA JEGT JEGT # 161010 <br /> INTERIOR ELEVATION TAG <br /> m X 305 <br /> T.O. LAND NO #I 16 8 MAGNETIG DOOR HOLD-OPEN TIED TO <br /> � cv � _ MARRIOTT # 446 <br /> _ BUILDING ALARM SYSTEM- REFER TO <br /> m \ L 18 1 6 ' N DOOR SCHEDULE, ELEG. 8 ALARM <br /> LN r =I I 1�Lu 5 O � DRAWINGS PERMIT # - <br /> O m - SEMI RECESSED FIRE EXTINGUISHER CABINET <br /> cv 3 2 4 APN # 058-66-012 <br /> �+1 3 <br /> � � � �i 2 DATE: 11/13/2018 <br /> 1oG 3 2311 HALL TYPES DRAWN: G.CUAJARPO <br /> 23, <br /> I HOUR FIRE PARTITION GHEGKED: D. BURKETT <br /> •� I I 106 ° � 202 I I <br /> Q m I HOUR FIRE BARRIER <br /> O <br /> v <br /> T.O. FINISH FLOOR #1 T.O. FINISH FLOOR #1 <br /> 2 HOUR FIRE BARRIER <br /> s a a a r 51 HhR #1 TYPICAL INTERIOR WALL <br /> TTT <br /> � d SHEE TITLE: <br /> STAIR DETAILS <br /> a a _ _ 111=111-111=111 I HOUR FIRE RATED EXTERIOR <br /> 106 FLOOR <br /> pj -III-III= a III-III i ik -ill-III-III-III I I=III- 2X6 WALL <br /> u� =111-III 1 1 1 = 1=111=11 a _ <br /> 111=1 <br /> 3 III= a -III-li' AD-7 =111-III a =111 N 5TI.IB FI-0-7 LANDING SEE SHEET A011 <br /> g <br /> 1oG STAIR NOSING <br /> s =1 I I-III-I 1 11 1 11 11=1 11=1 11=1 11=1 11=1 I I- 1=1 11=1 11=1 11=1 11=1 I I_I 11=1 11=1 11=1 11=1' <br /> -111 1I 1I 1I 1I 11 1I 11 L- 11 11 1I 1=1 11 11 1I 11 `� 202 BASE <br /> o -1 IIIII 1=1 1I 1I 1=1 11 _ ''=1 1I 1=1 1I ISI =1 1=1 1=1 <br /> =111111=III-III-III-III-1i -III-III-III=III-III=III=1'' O � HANDRAILS <br /> � 305 <br /> I <br /> 305 DOOR TRIM <br /> 305 WALL <br /> STAIR SEGT IONPLAN <br /> O 3'-11 1/4" 5'-8" NORTH SHEET NO.: <br /> 3 <br /> SCALE: 3/8" = 1'-0" <br /> lix-1 <br /> O <br /> SEE SHEETS AOII FOR WALL <br /> I I N L \ / LNLR/� D ✓T I R PLN ASSEMBLIES AND PENETRATION <br /> DETAILS <br /> A900 <br /> SEE SHEET AD7 IR FOR TYPICAL STADETAILS <br /> KEY PLAN <br />