My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3355
>
1600 - Food Program
>
PR0515486
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2020 3:43:04 PM
Creation date
8/25/2020 3:06:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0515486
PE
1625
FACILITY_ID
FA0012181
FACILITY_NAME
MCDONALDS #20612
STREET_NUMBER
3355
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
12618007
CURRENT_STATUS
01
SITE_LOCATION
3355 E HAMMER LN
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I m <br /> POS & COD ISOLATED GROUND/DEDICATED CIRCUIT <br /> KEY NOTES <br /> 4 SOLID #12 AWG THIS IS THE ONLY POINT WHERE THE ISOLATED <br /> • SHOWS CONNECTION/BONDING POINT ONLY. <br /> CONDUCTORS 8 ❑1 EQUIPMENT GROUNDING CONDUCTOR SHALL BE <br /> CONNECTED TO THE BUILDING'S GROUNDING SYSTEM. <br /> SEE BUILDING GROUNDING DETAIL THIS SHEET. <br /> (ORDER AREA) ELECTRICAL (PICK UP AREA) SERVICE ENTRANCE 3 PANEL CP 9 1-1/2" <br /> -1 P2 CND METAL 1CONDUIT:CU 4-#1T CU GND1-#6 CU <br /> RACEWAY (ADJUST (TYPICALLY MDP) COMPUTER ONLY <br /> TO BE 1 LESS A B G0 111- BLIJ 10 ALL ISOLATED GROUND/ DEDICATED CIRCUIT <br /> THAN COUNTER C BLK 100A-3P REL) W"T RECEPTACLE COVER PLATES SHALL BE ORANGE <br /> GRN WH STRIP HUBBELL PJ7CO (SINGLE), PJ8CO (ONE DUPLEX) OR Z <br /> LENGTH) BLU GRN PJ82CO (TWO DUPLEX) MARKED "COMPUTER ONLY". O <br /> WHT METAL JUNCTIO 11 <br /> 4 AWG GRN nW STRIP BOX METAL CONDUIT SHALL CONTAIN ONLY P.O.S. CIRCUIT a_ <br /> cRN 12 � CONDUCTORS (DEDICATED CIRCUIT). ONLY USE RIGID <br /> JBOX(S) ELECTRICAL JBOX(S) NON-METALLIC CONDUIT BELOW GRADE WHEN O <br /> FOR POWER _ _ _ _ RACEWAY TO BE FOR POWER N 5 13 REQUIRED BY LocAL coDE. W <br /> PULL BOX INSTALLED ON PULL BOX cRN rEw EQUIPMENT GROUNDING BONDING CONDUCTOR <br /> FOR DATA ® ® ® ® ® ® HORIZONTAL ® ® FOR DATA 6 � (TYPICAL) <br /> FRAMING10 <br /> ®® ea N ISOLATED GROUND BUS, ELECTRICALLY INSULATED <br /> 0 0 0 o MEMBER OR A 0 7 Ifl FROM PANEL ENCLOSURE USED TO TERMINATE ONLY <br /> PIECE OF ISOLATED EQUIPMENT GROUNDING CONDUCTORS. <br /> UNISTRUT L ALL CONDUCTORS SHALL BE SOLID COPPER AND <br /> 1 TERMINATED TO THEIR APPROPRIATE TERMINAL SCREWS <br /> BY WRAPPING THE CONDUCTOR COMPLETELY AROUND <br /> THE SCREW BARREL AND TIGHTENING THE SCREW PER <br /> 8 rr 2 MANUFACTURER'S TORQUE SPECIFICATIONS. <br /> ISOLATED GROUND RECEPTACLE <br /> 8 NOTES 191 HUBBELL-IG4700,IG471OJG5262 OR IG5261. SEE <br /> ROUGH IN SCHEDULE FOR THE APPROPRIATE I <br /> I ALL P.O.S. EQUIPMENT (COMPUTERS,PRINTERS,MONITORS RECEPTACLE TO USE. <br /> KVS, MODEM, HUB & COD) SHALL BE POWERED FROM 6. EC SHALL VERIFY THAT SUBPANEL CP DOES NOT CONTAIN <br /> SYMBOL CATALOG DESCRIPTION QUANTITY ANY ILLEGAL NEUTRAL TO GROUND BONDS. 10 ISOLATED GREEN GROUND SCREW. <br /> THE COMPUTER PANEL. w <br /> D HBLALU57DR & 104700 RECEPTACLE COVERPLATE WITH ORANGE, 1 PER ISOLATED GROUND RECEPTACLE 7. PANEL CP SHALL ONLY BE USED TO POWER SENSITIVE 11 ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN Q <br /> ALL OTHER COMPUTER/DIGITAL EQUIPMENT SHALL BE W/YLW STRIP) <br /> TWIST LOCK, ISOLATED GROUND POWERED FROM PHASE "A" IN THE COMPUTER PANEL. ELECTRONIC EQUIPMENT, AS OUTLINED IN NOTE #1. IT <br /> DUPLEX RECEPTACLE SHALL NOT BE USED TO POWER ANY OTHER LOADS. 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER SCREW. <br /> 2. ISOLATED GROUND INSTALLATION SHALL COMPLY WITH THE > <br /> Be HBLALU57DR & 515R RECEPTACLE COVERPLATE WITH 1 REQUIREMENTS OF NEC SECTION 250 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION FOR THE 13 PHASE CONDUCTOR TERMINATED ON BRASS SCREW I w <br /> STRAIGHT BLADE DUPLEX RECEPTACLE POS SYSTEM TO HAVE ITS OWN INDEPENDENT GROUNDING <br /> 3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN ISOLATED ROD. IF AN INDEPENDENT GROUND ROD IS FOUND FOR ENGINEER OF RECORD: <br /> D HBLALU57LPB COMMUNICATIONS COVERPLATE 1 PER REGISTER & 1 FOR DUAL POINT & 1 FOR ANALOG WIRELESS OPTION EQUIPMENT GROUNDING CONDUCTOR. THE POS SYSTEM, IT SHALL BE BONDED TO THE <br /> D HBLALU57BL BLANK COVERPLATE AS NECESSARY TO FILL RACEWAY BUILDING GROUNDING SYSTEM. <br /> 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY WITH NEC OFEs`5/p'�t <br /> D HBLALU7620B03M290 3' SECTION OF RACEWAY. INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER ARTICLE 250 AND MCDONALD's BUILDING GROUNDING <br /> COUPLERS LENGTH. INSTALL (2) 2' OR 3' RACEWAY AT PICKUP DETAIL. FER <br /> D HBLALU7620B02M290 2' SECTION OF RACEWAY, INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER 5. EC SHALL VERIFY CORRECT POLARITY AT RECEPTACLE. 7 <br /> COUPLERS LENGTH. INSTALL (2) 2' OR 3' RACEWAY AT PICKUP * ; <br /> ® HBLALU761 OB BLANK END FITTING AS NEEDED <br /> OF CAO1 <br /> HBLALU501OB2M2 SERVICE ENTRANCE FITTING & BUSHING AS NEEDED 9/6/19 <br /> FOR DATA CABLES <br /> N/A HBLALU5701 COUPLER INCLUDED WITH RACEWAY RECEIVE 1 PAIR PER RACEWAY SECTION <br /> SECTION) W <br /> N/A HBLALU5709 GROUND ADAPTER AS NEEDED B = unctix VIF = Verify in Feld ELECTRICAL SCHEDULE ~ moo <br /> Jo <br /> JB PB <br /> Box 14 <br /> EC = Electrical Contractor <br /> NOTES: TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS <br /> 1 . RACEWAY AND RECEPTACLES TO BE PROVIDED WITH MODULAR FRONT COUNTER, INSTALLED BY CONTRACTOR. ISOLATED <br /> 0o4.20Es 2 MENU BOARD - DIGITAL s.s 20A - - (z) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION <br /> ISOLATED <br /> 2. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE DEVIATIONS. SHORTER COUNTERS MAY REQUIRE CONTRACTOR 004.21E1 2 MENU BOARD - DIGITAL - MEDIA PLAYER 120/1 1.0 20A - - (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION <br /> ISOLATED (1) IG4700 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION V <br /> TO CUT RACEWAY FOR RACEWAY TO BE 1 ' SHORTER THAN COUNTER. 216.05E9 1 ORB MONITOR 120/1 ,.SEA zoA - - <br /> ISOLATED 'kinW <br /> JB WITH ONE (1) OPTION 2: r o 0 <br /> 1 1/2" CONDUIT TO 216.05 E9 JB WITH ONE (1) 2 1/2" RECESSED 4X12 ALUMINUM FIXED BLADE m a <br /> ABOVE CEILING WITH CONDUIT TO ABOVE CEILING WITH LOUVER TO EXHAUST INTO CAVITY. GC TO o 0 o, m <br /> MODULAR COMMTER RACEWAY P BUSHINGS FOR DATA 4.20 E3 BUSHINGS FOR DATA CABLES PROVIDE (1) LOUVER PER DMB. CENTER O U <br /> CABLES AROUND PROPOSED BRACKET LOCATION < ""o,o o it° <br /> o. <br /> EQ ca B CEILING OIL <br /> Cj <br /> o� <br /> SEE RCP X-C 4'-e II II <br /> m ° <br /> II <br /> II IIII <br /> •' '. II ° III <br /> IIIIIIIIIIII a _ IIIIIIII ____°_ - IIIIIIIII _ __a IIII �-n <br /> n C <br /> O <br /> N <br /> IF <br /> u 0� 0v 0 <br /> II ° <br /> IIII4.201111 E3 III _0 J ° D Q) -0 D o <br /> OPTION 1: -- -- ----- o ° o u <br /> _ I 4" CONDUIT SLEEVE THROUGH -s- - <br /> F `�� i "� VALANCE WALL TO ALLOW FOR g ° 0 ° L ° <br /> �,, t,.f�r -�` f �yti PASS THROUGH OF DATA CABLE. E .- - 1'o <br /> ;4 t5 DUAL POINT PICK-UP 'J, I PROVIDE BUSHING ON EACH END. a 0 5 <br /> NEW ELECTRICAL STATION OVERSHELF A y PASS-THROUGH CAN BE ANGLED O c o o 0 0 <br /> ELECTRICAL AS NEEDED TO COORDINATE WITH = ° o <br /> 0 3 0 ° <br /> RECEPTACLES FOR MINI [J RECEPTACLE FOR ORB. ° U o o ° : o <br /> ORB AND SCANNER 71.13 E3 CEILING BEHIND AND <br /> VERIFY LOCATION IN ------, CONDITIONS ,w 0 0 0 0 <br /> NEW ELECTRICAL - - - --- - <br /> CEILING. 0 .�'n 0 <br /> V D Q 0 <br /> RECEPTACLE FOR ORB. - 0 0 o ° ° <br /> VERIFY LOCATION IN 2 4" 14 3'-0" 2'-7" <br /> O U N V n <br /> CEILING. �F 3'-0" MIhJ. 2'-6" MIN. 2'-S" MIN. <br /> 2 ra r� _ <br /> I cn rn cQ L_31 U1 co L51 LD cn c4€s1 4'-0" STD. 3'-0" STD. 3'-0" STD. oo <br /> o oco b b as ao U U) 0 m <br /> j I cn o 0 0 0 0 0 0 0 0 5'-0" MAX. 3'-0" 7" 3'-4" MpX. 3'-4" MAX. -2' T/FINISHED FLOOR O 0 <br /> ADA HOLD oW .L`� O'er •"'� <br /> rn m mm m rnm mrn rnrn 3" ( } <br /> O 0 -� I 3 4,a 1 G�1 C-y -� OVERALL COUNTER LENGTH VARIES 0 0 F <br /> OVERALL COUNTER LENGTH VARIES SEE CHART BELOW) ELEV. + 0'-0" ° V ° - o <br /> SEE CHART BELOW) EXISTING EQUIPMENT QUARRY TILE COVE BASE o N o Q° <br /> +� Q(n L <br /> ALT: SCHLUTER DILEX-AHK 0 ° 0 ° ° <br /> 0-0 <br /> '0- <br /> FRONT COUNTER ELECTRICAL ROUGH-INS FRONT COUNTER WRH DUAL POINT INCORPORATED NOTE: OPTION 1 IS PREFERRED IF AREA BEHIND BOARDS IS A o o <br /> s NTS IRs RECESSED MENU BOARDS o � <br /> NON-CUSTOMER AREA AND MEDIA PLAYERS WON'T BE INSTALLED w 0 ° L 0 <br /> NTS ABOVE FOOD PREP. SLEEVES SHOULD NOT BE INSTALLED WITHIN o ® -0 3 °--o o� <br /> SAMPLE ELECTRICAL SCHEDULE CUSTOMER VIEW. IF AREA BEHIND MENU BOARDS O DINING, ° 0 o o ° <br /> RESTROOMS, OR OTHER CUSTOMER-FACING LOCATION, USE OPTION 2. 0- �; o� (D L o <br /> W t � - O O� N� <br /> TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE CQND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS ~ °-3 E U <br /> m <br /> 215.00E1 4 POS PC HARDWARE - FRONT COUNTER 120/1 3.1) EA. 20A 1/2"C-2#121G CP;17 1134700 2'-0" EC TO RUN 3/4" COND IN WALL FOR FLUSH MTD SPCL. RECEP <br /> ISOLATED FOR KEYSTATIONS (MONITOR,CPU & CASH DRAWERS) z o <br /> 215.00E5 1 POS PC HARDWARE - FRONT COUNTER DATA CABLE - - - - 4x4x4 PB 1'-6" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.00E7 FOR POS DATA o °� O W O w <br /> CABLES OPTION 2: JB WITH ONE (1) 1" CONDUIT m O U <br /> ACCESSORY o co N co <br /> 216.04E1 1 ORB MONITOR (MINI) 120/1 1.5 EA. 20A 1/2"C-2#121G CP:17 IC47D0 1'-6" - SYSTEM WITH JB WITH TWO (2) 2 TO ABOVE CEILING WITH z N w n \ N <br /> ISOLATED MONITOR 0 . ® 1/2" CONDUIT TO BUSHINGS FOR DATA CABLES '> w w w w CD a <br /> LEVELING ABOVE CEILING WITH U z > w I O o <br /> 216.05E1 1 ORB MONITOR 120f1 1.5 EA. 20A 1/2"C-2#12113 CP:4 IG4700 FLUSH ON - CLIPS KTO 0 o CONTROL o D W L, Q \ 0 U <br /> ISOLATED CLG BUSHINGS FOR DATA o m . o � <br /> ACCESSORY ` o A o ' _D _D O n <br /> 219.ODE3 4 POS - RECEIPT PRINTER/CASHLESS 120/1 D.7 20A 1/2"C-2#121G CP;4,5 SEE RMKS IC47DO 2'-0" FOR RECEIPT LOCATED IN FRONT COUNTER POWER FROM CP:14 IN SYSTEM o ® 1� o CABLES 1 v �j <br /> ISOLATED PRESENTER'S BOOTH CP:4 0 0 <br /> 701.13E3 1 DCO - GENERAL PURPOSE 120/1 1.5 20A 1/2"C-2#12 AP-2:6 5-20R 1'-g" - o a o ®® MEDIA PLAYER <br /> � o <br /> DUAL POINT CONVERSION NOTES: E. o El El <br /> 1 . ADDITIONAL POWER FOR CREW MINI-ORB AND SCANNER LOCATED UNDER COUNTER. SEE 216.04/DETAIL 1 (ELECTRICAL ROUGH-INS) 0 � � 0 s" o <br /> 2. ADDITIONAL POWER FOR CUSTOMER ORB MONITOR INSTALLED AT FACE OF SOFFIT. SEE 216.05/DETAIL 1 (ELECTRICAL ROUGH-INS) BOTTOM OF VALANCE Y <br /> 3. SEQUENCE MENU BOARDS PER DUAL POINT STANDARDS V-5" o <br /> 4. NON-SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH CBB CELL WITH 1 OF 12 APPIROVED LAMINATE SELECTIONS. KES TO ORDER FROM DECOR ° o o ° OPTION 1: HORIZONTAL DIMENSIONS <br /> 4" CONDUIT SLEEVE REFERENCED FROM LEFT <br /> COMPANY. (VERIFIED AT TIME OF SURVEY) INSTALLATION THROUGH VALANCE WALL <br /> 5. SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH DECOR FRONT COUNTER CORIAN SPECIFICATION, GC TD FABRICATE AND INSTALL TO MOUNTING SUPPORTS TO ALLOW FOR PASS <br /> THROUGH OF DATA CABLE. <br /> SPECIFICATIONS, (LINEN OR RICE PAPER) PROVIDE BUSHING ON w <br /> 6. SIGNAGE PACKAGE PROVIDED BY KES AND INSTALLED BY G.C. *SECURE TO EXISITING STUDS OR 3/4" PLYWOOD BACKING EACH END. SLEEVE CAN I> <br /> 7. ADA PLATFORM SOLUTION DOES NOT MEET ADA REQUIREMENTS IN CA, IL QR FL. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS BE ANGLED WHEN z Q z <br /> 8. 3'-0" MINIMUM ADA SPACE REQUIRED BETWEEN END OF PICK-UP SHELF AND FIRST KEYSTATIOPJ NECESSARY U 0 o z <br /> Lj Li <br /> 9. ORDER READY BOARD TO BE CENTERED ON PICK-UP SHELF OR ADA PLATFORM. DIGITAL MENU BOARD BRACKET DETAIL BACK OF WALL VALANCE z Ld � > <br /> NTS NTS Q D w = <br /> THIS SLIP SHEET IS PROVIDED FOR REFERENCE ONLY. ADDITIONAL MODIFICATIONS TO THE HLZ, CENTER ISLAND AND POS SYSTEM WILL BE REQUIRED TO - � U) <br /> COMPLETE THE DUAL POINT SERVICE INSTALLATION. PLEASE VERIFY LAYOUT, NUMBER OF KEYSTATIONS AND DIMENSIONS WITH KES AND REGIONAL DUAL POINT LL m Q w <br /> LEAD PRIOR TO FABRICATION OR INSTALLATION. DIGITAL MENU BOARD (DMB) INSTALLATION NOTES: KEY NOTES w W Ln <br /> • DMB SUPPORT EQUIPMENT INCLUDES: z O <br /> - NETWORK MANAGEMENT DEVICE (NMD) 1❑THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL ROUGH-IN W Q w <br /> DUAL POINT FRONT GRUNTER PLANS - 24 PORT ENHANCED WAYPORT SWITCH (EWS) PREPARATION AND GENERAL DIGITAL MENU BOARD MOUNTING z <br /> THIS EQUIPMENT IS TYPICALLY MOUNTED IN GUIDELINES. EVALUATE EXISTING VALANCE WALL STRUCTURE 0-) a w w o <br /> $ L. N4j, TECHNOLOGY CLOSET OR IN MANAGER'S AND BACKING MATERIALS TO ENSURE ADEQUATE SUPPORT OF <br /> OFFICE. EQUIPMENT. w o o � � � <br /> • DMB INSTALLERS TO ROUTE CONTROL WIRES FROM \ W v w k o <br /> NMD/EWS ABOVE CEILING TO MENU BOARD ❑2 ALL HEADER AND WALL PENETRATIONS FOR CONDUITS \ W Ln o <br /> VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. OR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT. <br /> • EACH DMB SECTION REQUIRES A DEDICATED MEDIA <br /> PLAYER. oz <br /> w E490 <br /> In ROUGH IN DETAILS <br />
The URL can be used to link to this page
Your browser does not support the video tag.