FACILITY_NAME
MCDONALDS #14444
STREET_NUMBER
6440
Direction
W
STREET_NAME
BANNER
STREET_TYPE
ST
City
LODI
Zip
95242
APN
05532018
CURRENT_STATUS
01
SITE_LOCATION
6440 W BANNER ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I M <br /> POS & COD ISOLATED GROUND/DEDICATED CIRCUIT <br /> KEY NOTES <br /> 4 SOLID #12 AWG THIS IS THE ONLY POINT WHERE THE ISOLATED <br /> • SHOWS CONNECTION/BONDING POINT ONPPER CONDUCTORS 8 I EQUIPMENT GROUNDING CONDUCTOR SHALL BE <br /> CONNECTED TO THE BUILDING'S GROUNDING SYSTEM. <br /> SEE BUILDING GROUNDING DETAIL THIS SHEET. <br /> (ORDER AREA) ELECTRICAL (PICK UP AREA) SERVICE ENTRANCE 3 PANEL CP 9 1-1/2" METAL CONDUIT: 4-#1 CU + 1-#6 CU <br /> RACEWAY (ADJUST (TYPICALLY MDP) COMPUTER ONLY ® EQUIP GND + 1-#4 CU ISOLATED GND. <br /> TO BE 1' LESS a B c BL1< A B c BLU 10 ❑¢ ALL ISOLATED GROUND/ DEDICATED CIRCUIT <br /> THAN COUNTER 100A-3P RED RECEPTACLE COVER PLATES SHALL BE ORANGE <br /> wrtT <br /> cRN w STRIP HUBBELL PJ7CO (SINGLE), PJ8CO (ONE DUPLEX) OR Z <br /> LENGTH BLU cRN PJ82CO (TWO DUPLEX) MARKED "COMPUTER ONLY". O <br /> w"r METAL JUNCTIO 11 � <br /> 4 AWG cRN w STRIP BOX METAL CONDUIT SHALL CONTAIN ONLY P.O.S. CIRCUIT <br /> GRN 12 CONDUCTORS (DEDICATED CIRCUIT). ONLY USE RIGID <br /> J-BOX(S) ELECTRICAL J-BOX(S) N 5 REQUIRED BY LOCAL CODE. <br /> NON-METALLIC CONDUIT BELOW GRADE WHEN <br /> FOR POWER _ _ _ _ RACEWAY TO BE FOR POWER 13 0 <br /> PULL BOX INSTALLED ON PULL BOX GRN w EQUIPMENT GROUNDING BONDING CONDUCTOR <br /> H O R I Z O NTAL 6 (TYPICAL) <br /> FOR DATA FOR DATA <br /> ® ® ® ® ® ® ® FRAMING ® ® ® N ISOLATED GROUND BUS, ELECTRICALLY INSULATED <br /> O O O O MEMBER OR A O 7 FROM PANEL ENCLOSURE USED TO TERMINATE ONLY <br /> PIECE OF G ISOLATED EQUIPMENT GROUNDING CONDUCTORS. <br /> UNISTRUT G ❑ ALL CONDUCTORS SHALL BE SOLID COPPER AND <br /> L+ 1 8 TERMINATED TO THEIR APPROPRIATE TERMINAL SCREWS <br /> BY WRAPPING THE CONDUCTOR COMPLETELY AROUND <br /> ir <br /> THE SCREW BARREL AND TIGHTENING THE SCREW PER <br /> 2 MANUFACTURER'S TORQUE SPECIFICATIONS. <br /> 8 8 NOTES HUB BELDL-G40700,IG4710,IIG5262 OR IG5261. SEE <br /> ROUGH IN SCHEDULE FOR THE APPROPRIATE <br /> 1. ALL P.O.S. EQUIPMENT (COMPUTERS,PRINTERS,MONITORS RECEPTACLE TO USE. <br /> KVS, MODEM, HUB & COD) SHALL BE POWERED FROM 6. EC SHALL VERIFY THAT SUBPANEL CP DOES NOT CONTAIN 10 ISOLATED GREEN GROUND SCREW. <br /> SYMBOL CATALOG # DESCRIPTION QUANTITY THE COMPUTER PANEL. ANY ILLEGAL NEUTRAL TO GROUND BONDS. w <br /> 7. PANEL CP SHALL ONLY BE USED TO POWER SENSITIVE 11 ISOLATED EQUIPMENT GROUNDING CONDUCTOR (GRN Q <br /> I HBLALU57DR & IG4700 RECEPTACLE COVERPLATE WITH ORANGE, 1 PER ISOLATED GROUND RECEPTACLE ALL OTHER COMPUTER/DIGITAL EQUIPMENT SHALL BE H W/YLW STRIP) o <br /> TWIST LOCK, ISOLATED GROUND POWERED FROM PHASE "A" IN THE COMPUTER PANEL. ELECTRONIC EQUIPMENT, AS OUTLINED IN NOTE #1. IT <br /> SHALL NOT BE USED TO POWER ANY OTHER LOADS. 12 NEUTRAL CONDUCTOR TERMINATED ON SILVER SCREW. <br /> DUPLEX RECEPTACLE 2. ISOLATED GROUND INSTALLATION SHALL COMPLY WITH THE > <br /> D HBLALU57DR & 5-15R RECEPTACLE COVERPLATE WITH 1 REQUIREMENTS OF NEC SECTION 250 . 8. IT IS A SAFETY HAZARD AND AN NEC VIOLATION FOR THE 13 PHASE CONDUCTOR TERMINATED ON BRASS SCREW w <br /> POS SYSTEM TO HAVE ITS OWN INDEPENDENT GROUNDING ft� <br /> STRAIGHT BLADE DUPLEX RECEPTACLE3. EACH 20 AMP CIRCUIT SHALL HAVE IT'S OWN ISOLATED ROD. IF AN INDEPENDENT GROUND ROD IS FOUND FOR ENGINEER OF RECORD: <br /> D HBLALU57LPB COMMUNICATIONS COVERPLATE 1 PER REGISTER & 1 FOR DUAL POINT & 1 FOR ANALOG WIRELESS OPTION EQUIPMENT GROUNDING CONDUCTOR. THE POS SYSTEM, IT SHALL BE BONDED TO THE <br /> BUILDING GROUNDING SYSTEM. <br /> D HBLALU57BL BLANK COVERPLATE AS NECESSARY TO FILL RACEWAY 4. ENTIRE GROUNDING SYSTEM SHALL COMPLY WITH NEC 1yFE5S1- <br /> 0 HBLALU7620B03M290 3' SECTION OF RACEWAY. INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER ARTICLE 250 AND MCDONALD's BUILDING GROUNDING FER <br /> COUPLERS LENGTH. INSTALL (2) 2' OR 3' RACEWAY AT PICKUP DETAIL. f <br /> D HBLALU7620B02M290 2' SECTION OF RACEWAY, INCLUDES AS NECESSARY TO MAKE ORDER COUNTER RACEWAY 1 ' LESS THEN COUNTER <br /> 5. EC SHALL VERIFY CORRECT POLARITY AT RECEPTACLE. (/ 7 <br /> COUPLERS LENGTH. INSTALL (2) 2' OR 3' RACEWAY AT PICKUP <br /> ® HBLALU761OB BLANK END FITTING AS NEEDED af�T OF CAILN0'`�' <br /> ® HBLALU5010B2M2 SERVICE ENTRANCE FITTING & BUSHING AS NEEDED 4/25/19 <br /> FOR DATA CABLES <br /> crs �r � z <br /> NIli <br /> /A HBLALU5701 COUPLER (INCLUDED WITH RACEWAY RECEIVE 1 PAIR PER RACEWAY SECTION W 0 <br /> SECTION) I o <br /> N/A HBLALU5709 GROUND ADAPTER AS NEEDED JPB xB = JuPullnctibo <br /> Box VIF = Verify in Feld ELECTRICAL SCHEDULE Q <br /> EC = Electrical Contractor <br /> NOTES: TAEQMENU - DIGITAL TY MOTIONVOLT/PH <br /> LT PH SA <br /> LA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS <br /> 1. RACEWAY AND RECEPTACLES TO BE PROVIDED WITH MODULAR FRONT COUNTER, INSTALLED BY CONTRACTOR. 23 120/1ED (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION <br /> ISOLAT <br /> 2. DETAIL SHOWN IS A TYPICAL CONFIGURATION ONLY. SITE SPECIFICS MIGHT CAUSE DEVIATIONS. SHORTER COUNTERS MAY REQUIRE CONTRACTOR 004.21E1 2 MENU BOARD - DIGITAL - MEDIA PLAYER 120/1 1.0 20A - - (2) IG5262 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION <br /> ISOLATED <br /> TO CUT RACEWAY FOR RACEWAY TO BE 1' SHORTER THAN COUNTER. 216.05E9 1 ORB MONITOR 120/1 1.5EA 20A - - (1) IG4700 SEE PLAN SEE LAYOUT FOR GANGED OUTLET CONFIGURATION 'kin <br /> W <br /> JB WITH ONE (1) OPTION 2: } E <br /> 1 1/2" CONDUIT TO 216.05 E9 JB WITH ONE (1) 2 1/2" RECESSED 4X12 ALUMINUM FIXED BLADE m o <br /> �n� Y ABOVE CEILING WITH CONDUIT TO ABOVE CEILING WITH LOUVER TO EXHAUST INTO CAVITY. GC TO o a N <br /> �� tl tl I ® BUSHINGS FOR DATA 4.20 E3 BUSHINGS FOR DATA CABLES PROVIDE (1) LOUVER PER DMB. CENTER w O � Q - <br /> MODUCABLES AROUND PROPOSED BRACKET LOCATION d Cm o <br /> w o� MP3 <br /> B CEILING � o^ o <br /> eo m �______ �__ ==11�====__��____ �� _ ___� w .50v <br /> g s-s III 4'-e IIII I SEE RCP <br /> I I <br /> II III. .IIII. .IIII. All <br /> II ' III '. 1111 ' IIII ' III 11 o a> � �pv <br /> p O p O <br /> O L � p � i <br /> o No 0 <br /> H 11 II o L Qap a1 p v <br /> III CJ O 12 w 0 p p <br /> I III III I O J o a�� o <br /> 0 <br /> I III IIII 4.201111 E3 III II j ° �a O o_o <br /> 1 -- --=JL======JL=====_ -----=JL======J ° o ° a1 a1 E.pof c <br /> OPTION 1: o ., ° °' '- O <br /> p <br /> i F.-------- j---�� -- ------ ' tit jII 4" CONDUIT SLEEVE THROUGH Qc o--- co pai <br /> VALANCE WALL TO ALLOW FOR <br /> �c o <br /> PASS THROUGH OF DATA CABLE. W E•--1 oa,i <br /> DUAL POINT PICK-UP '� I I PROVIDE BUSHING ON EACH END. V♦ 73 ° °'rn o <br /> 2, STATION OVERSHELF I O ° O <br /> �, � I PASS-THROUGH CAN BE ANGLED N o ° <br /> NEW ELECTRICAL '_ ELECTRICAL ` ` AS NEEDED TO COORDINATE WITH 0 <br /> RECEPTACLES FOR MINI (J RECEPTACLE FOR ORB. I CEILING BEHIND AND EXISTING o a 0 O ° c O <br /> ORB AND SCANNER 701.13 E3 -------------- <br /> VERIFY LOCATION IN I------- CONDITIONS <br /> NEW ELECTRICAL - OEILING. I - 0 c'6 Ern <br /> I p o,3'p E v 0 <br /> RECEPTACLE FOR ORB. - - - - - - - - - - i ° o 0 o °;? ° <br /> VERIFY LOCATION IN z 4" 14 3'-O" 2'-7" 2" <br /> CEILING. MIhJ. 12-8 <br /> I I U ° ` n <br /> ra ra ra r r� ra r a r�r� r�r a ° <br /> 2-8" MIN. 2'-8" MIN. I 1 _J~ p o o api <br /> I aS m 1.0 LTt LJ1 cD cs Ln cn c0 cs1 4'-0" STD. 3'-0" STD. 3'-0" STD. I I O Q ° (D 0 i_ <br /> O O b O L'] d 0 Q� C�O I I ;� �n O N ° c N O <br /> f I CJ Q O O o O Q o Q C] 5'-0" MAX. 3'-O" 3'-4" MAX. 3'-4" MAX. '-2' O c ° ° <br /> -� R f3 1 11 m -� 3 OVERALL COUNTER LENGTH VARIES ELEV. + 0'-0" o `1 2:,°' <br /> AOA HOEo T/FINISHED FLOOR w .° <br /> 2 IV• - <br /> 7 Q 7 O 7 <br /> OVERALL COUNTER LENGTH VARIES SEE CHART sFEow EXISTING EQUIPMENT QUARRY TILE COVE BASE ♦� o o � <br /> - SEE CHART BELOW ALT: SCHLUTER DILEX-AHK �,/ o �-0 <br /> FRONT COUNTER ELECTRICAL ROUGH INS FRONT COUNTER WRH DUAL POINT INCORPORATED NOTE: OPTION 1 IS PREFERRED IF AREA BEHIND BOARDS IS A O 3 w o - <br /> 1 "'S IIS "rs RECESSED MENU BOARDS NON-CUSTOMER AREA AND MEDIA PLAYERS WON'T BE INSTALLED LL p o L o 0 0 ° <br /> ® L 3 0 o <br /> °" ° n ° <br /> NTS ABOVE FOOD PREP. SLEEVES SHOULD NOT BE INSTALLED WITHIN �w ° <br /> SAMPLE ELECTRICAL SCHEDULE CUSTOMER VIEW. IF AREA BEHIND MENU BOARDS IS DINING, QEE N Qo U) <br /> RESTROOMS, OR OTHER CUSTOMER-FACING LOCATION, USE OPTION 2. w o- `o a1 L a1 <br /> TAG # QTY DESCRIPTION VOLT/PH FLA BRK SIZE COND/WIRE PNL/CCT RECEP TYPE HGT AFF REQUIREMENTS & REMARKS w o _I_-..� rn <br /> o <br /> � O 3 0 c ..- <br /> 215.0DE1 4 POS PC HARDWARE - FRONT COUNTER 120/1 3.D EA. 20A 1/2"C-2#121G CP;17 1134740 2'-D" EC TO RUN 3/4" GOND IN WALL FOR FLUSH MTD SPOIL. RECEP <br /> ISOLATED FOR KEYSTATIONS (MONITOR,CPU & CASH DRAWERS) Ld z Q <br /> 215.44E5 1 P05 PC HARDWARE - FRONT COUNTER DATA CABLE - - - - 4x4x4 PB 1'-6" EXTEND 2 1/2" CONDUIT UNDER SLAB TO 215.00E7 FOR POS DATA } o - m O w U N <br /> CABLES OPTION 2: JB WITH ONE 1 1" CONDUIT DD O 0 V) LO \ � (.0 <br /> 216.04E1 1 ORB MONITOR MINI 120 1 1.5 EA. 20A 1 2"C-2 121G CP:17 IC47DO 1'-g" - ACCESSORY z N w Ln Lo <br /> (MINI) / I # o o JB WITH TWO (2) 2 TO ABOVE CEILING WITH = w CD N <br /> ISOLATED MONITOR ® SYSTEM WITH 3 O cn w w a N <br /> • e LEVELING 1/2" CONDUIT TO BUSHINGS FOR DATA CABLES a v_1 z > \ <br /> 21 e.oSE� 1 oRe MONITOR 120 f 1 1.5 EA. 20A 1/2"c-a#�21� CP:4 Ic470o EwsH arJ - BRACKET e e ABOVE CEILING WITH o Q LJ Q <br /> ISOLATED cLG CLIPS TO 6 a CONTROL o o O <br /> 219.DDE3 4 POS - RECEIPT PRINTER/CASHLESS 12C/1 0.7 20A 112"C-2#1 21G CP:4,8 SEE RMKS IC47DO 2'-0" FOR RECEIPT LOCATED IN FRONT COUNTER POWER FROM CP:4 IN ACCESSORY O o ® 0 0 BUSHINGS FOR CABLES N N <br /> ISOLATED PRESENTER'S BOOTH CP:4 SYSTEM o a <br /> 1 v <br /> 701.13E3 1 DCO - GENERAL PURPOSE 120/1 1.5 20A 1/2"C-2#12 AP-2:6 5-20R 1'-6" - o a MEDIA PLAYER <br /> JoelN <br /> DUAL POINT CONVERSION NOTES: ° o ' Ln <br /> ❑❑ Q <br /> 1 . ADDITIONAL POWER FOR CREW MINI-ORB AND SCANNER LOCATED UNDER COUNTER. SEE 216.04/DETAIL 1 (ELECTRICAL ROUGH-INS) <br /> 2. ADDITIONAL POWER FOR CUSTOMER ORB MONITOR INSTALLED AT FACE OF SOFFIT. SEE 216.05/DETAIL 1 (ELECTRICAL ROUGH-INS) 0 O 6"" <br /> BOTTOM OF VALANCE <br /> o <br /> 3. SEQUENCE MENU BOARDS PER DUAL POINT STANDARDS cc 0 V-5" J <br /> 4. NON-SEEQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH CBB CELL WITH 1 OF 12 APPROVLD LAMINATE SELECTIONS. KES TO ORDER FROM DECOR ° 0 ® ° OPTION 1: HORIZONTAL DIMENSIONS <br /> COMPANY. (VERIFIED AT TIME OF SURVEY) o 0 4" CONDUIT SLEEVE REFERENCED FROM LEFT <br /> 5, SELQ INSTALL - PICK-UP SHELF MATERIALS TO MATCH DECOR FRONT COUNTER CORIAN SPECIFICATION, CC TO FABRICATE AND INSTALL TO INSTALLATION THROUGH VALANCE WALL <br /> MOUNTING SUPPORTS TO ALLOW FOR PASS <br /> SPECIFICATIONS, (LINEN OR RICE PAPER) THROUGH OF DATA CABLE. > <br /> 6. SIGNAGE PACKAGE PROVIDED BY KES AND INSTALLED BY G.C. *SECURE TO EXISITING STUDS OR 3/4" PLYWOOD BACKING PROVIDE BUSHING ON (� > <br /> EACH END. SLEEVE CAN g <br /> 7. ADA PLATFORM SOLUTION DOES NOT MEET ADA REQUIREMENTS IN CA, IL OR FL. BE ANGLED WHEN Q z <br /> REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS O z N <br /> 8. 3'-0" MINIMUM ADA SPACE REQUIRED BETWEEN END OF PICK-UP SHELF AND FIRST KEYSTATIOfJ NECESSARY U CD � - <br /> Uj <br /> 9. ORDER READY BOARD TO BE CENTERED ON PICK-UP SHELF OR ADA PLATFORM. Z <br /> w �Z <br /> DIGITAL MENU BOARD BRACKET DETAIL BACK OF WALL VALANCE U Q Z:) m <br /> THIS SLIP SHEET IS PROVIDED FOR REFERENCE ONLY. ADDITIONAL MODIFICATIONS TO THE HLZ, CENTER ISLAND AND POS SYSTEM WILL BE REQUIRED TO NTS <br /> NTS 0m0 J o w o N <br /> COMPLETE THE DUAL POINT SERVICE INSTALLATION. PLEASE VERIFY LAYOUT, NUMBER OF KEYSTATIONS AND DIMENSIONS WITH KES AND REGIONAL DUAL POINT m w Q <br /> LEAD PRIOR TO FABRICATION OR INSTALLATION. DIGITAL MENU BOARD (DMB) INSTALLATION NOTES: KEY NOTES z Li_ w Cc)• DMB SUPPORT EQUIPMENT INCLUDES: Q 0 _j Uj <br /> - NETWORK MANAGEMENT DEVICE (NM1❑D) THIS SLIP SHEET IS PROVIDED FOR ELECTRICAL ROUGH-IN z z g 3 <br /> DUAL POINT FRONT COUNTER PLANS - 24 PORT ENHANCED WAYPORT SWITCH (EWS) PREPARATION AND GENERAL DIGITAL MENU BOARD MOUNTING of w Oro <br /> THIS EQUIPMENT IS TYPICALLY MOUNTED IN GUIDELINES. EVALUATE EXISTING VALANCE WALL STRUCTURE O� (� q UJ E n <br /> N.T.S. AND BACKING MATERIALS TO ENSURE ADEQUATE SUPPORT OF <br /> TECHNOLOGY CLOSET OR IN MANAGER'S w - v 0- N <br /> OFFICE. EQUIPMENT. O X W o w w <br /> • DMB INSTALLERS TO ROUTE CONTROL WIRES FROM N W 0❑2 N o <br /> NMD/EWS ABOVE CEILING TO MENU BOARD ALL HEADER AND WALL PENETRATIONS FOR CONDUITS <br /> VALANCE WALL. WIRES TO EXIT WALL VIA J-BOXES. OR OTHER ELECTRICAL ROUTING MUST BE SEALED TIGHT. <br /> • EACH DMB SECTION REQUIRES A DEDICATED MEDIA oz <br /> PLAYER. <br /> w • <br /> 0 <br /> U) ROUGH IN DETAILS <br />
The URL can be used to link to this page
Your browser does not support the video tag.