Laserfiche WebLink
rREV1510N5 BY <br /> GENERAL NOTES : <br /> 1. ELECTRICAL CONTRACTOR SHALL VERIFY (E) FIELD CONDITIONS PRIOR TO BID. ANY DISCREPANCIES BETWEEN <br /> DRAWINGS & (E) CONDITIONS FOUND DURING INSTALLATION SHALL BE BROUGHT TO THE ENGINEER'S <br /> ATTENTION & SHOULD BE RESOLVED AT NO ADDITIONAL COST TO THE OWNER. <br /> 2. ALL WIRING TO BE COPPER "THWN," UNLESS OTHERWISE NOTED. SEE PANEL SCHEDULE FOR SIZING. CONSULTANT <br /> 3• ELECTRICAL CONTRACTOR TO SUPPLY OWNER WITH DRAWINGS OF THE AS—BUILT CONDITION OF THE WIRING <br /> SYSTEM UPON COMPLETION. 2249,° r. <br /> CAN5 <br /> Pittsburg,CA 94565 <br /> phone'.(510)288-1228 <br /> 4, ALL CONSTRUCTION OF THIS PROJECT SHALL CONFORM TO ALL LOCAL CODES, ORDINANCES AND CURRENT ga1tlepo11a@9ede°eZ°50°'°9­ <br /> ELECTRIC & BUILDING CODES. ENERGY CONSUL TING <br /> & ENGINEERING SER VICES <br /> 5. THE E.0 SHALL COMPLY WITH ALL LOCAL COUNTY, STATE AND FEDERAL CODES, ORDINANCES, RULES AND www.geoenergyconsult/ng.cora <br /> REGULATIONS INCLUDING ALL REQUIREMENTS OF GOVERNING AGENCIES. ELECTRICAL CONTRACTOR SHALL PAY <br /> ALL COSTS, ASSOCIATED WITH THE INSTALLATION, INCLUDING BUILDING APPLICATION FEES, ETC. <br /> 6. ALL ELECTRICAL ROUGH—INS SHOWN ON THIS PLAN PERTAINS ONLY TO THE EQUIPMENT BEING FURNISHED ESS/ONy <br /> BY VENDOR. ANY ADDITIONAL REQUIREMENTS SHALL BE SPECIFIED BY THE OWNER AND/OR THE GENERAL ��� �aPN "v �F <br /> CONTRACTOR. s` �G" <br /> rn <br /> � Z <br /> 7, ALL DISCONNECTING MEANS SHALL BE IDENTIFIED FOR ITS PURPOSE PER LATEST EDITION OF NEC ARTICLE Ex 21313 <br /> 110.22. Exp.09-30-21 <br /> 1 , <br /> 8. EVERY STRUCTURE AND PORTION THEREOF, INCLUDING NONSTRUCTURAL COMPONENTS THAT ARE �F CAL�FO��\� <br /> PERMANENTLY ATTACHED TO STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS, SHALL BE DESIGNED <br /> AND CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE MOTIONS IN ACCORDANCE WITH ASCE 7, <br /> EXCLUDING CHAPTER 14 AND APPENDIX 11A. THE SEISMIC DESIGN CATEGORY FOR A STRUCTURE IS <br /> PERMITTED TO BE DETERMINED IN ACCORDANCE WITH SECTION 1613 OR ASCE 7. <br /> 9. ALL DISCONNECTING MEANS AND ELECTRICAL EQUIPMENT SHALL BE INSTALLED PER 110.3(B) OR PER THE <br /> LISTING AND LABELING INSTRUCTIONS BY THE MANUFACTURERS. <br /> 10. INSTALL BUSHING ON ALL RACEWAY ENTRIES CONNECTORS THAT CONTAIN 4 AWG OR LARGER CONDUCTORS. <br /> 11. ALL 15 AND 20—AMPERE, 125 AND 250—VOLT RECEPTACLES INSTALLED IN A WET LOCATION SHALL HAVE AN <br /> ENCLOSURE THAT IS WEATHERPROOF WHETHER OR NOT THE ATTACHMENT PLUG CAP IS INSERTED. <br /> 12. ALL HVAC UNITS SHALL HAVE PROPERLY FUSED DISCONNECTING MEANS AND A GFCI PROTECTED RECEPTACLE <br /> SHALL BE INSTALLED WITHIN 25 FEET OF ALL HVAC AND VENTILATING EQUIPMENT ON THE ROOF. <br /> 13. ELECTRICAL PLANS ARE INTENDED TO SHOW, IN A GENERAL WAY, THE APPROXIMATE LOCATION AND LOADS <br /> OF THE INTENDED FIXTURE AND EQUIPMENT. EXACT LOCATIONS AND MATERIALS SHALL BE DETERMINED IN <br /> THE FIELD BY THE INSTALLING CONTRACTOR AND SHALL CONFORM TO THE PROVISIONS AS SET FORTH IN <br /> 00 00 00 00THE 2016 EDITION OF THE CALIFORNIA ELECTRICAL CODE, 2016 EDITION OF THE CALIFORNIA ENERGY CODE <br /> o AND THE 2016 CALIFORNIA GREEN BUILDING CODE. <br /> 14. PROVIDE A SEPARATE NEUTRAL CONDUCTOR FOR EACH AND EVERY PHASE (LINE) CONDUCTOR; TO COMPLY <br /> WITH CEC ARTICLE 210.4 FOR MULTI—WIRE CIRCUITS AND TO PERMIT INDIVIDUAL OPERATION/CONTROL OF <br /> EACH BRANCH CIRCUIT OR PROVIDE TIE HANDLE ON BREAKERS TO SUIT SINGLE NEUTRAL ON <br /> MULTI—CIRCUITS HOMERUNS— NEUTRAL MUST BE MINIMUM #10 ON MULTI CIRCUITS. <br /> SHEET NOTES : <br /> O PROVIDE WEATHERPROOF AND GFCI PROTECTED RECEPTACLES WITHIN 25 FT. OF ROOFTOP EQUIPMENT PER z <br /> CEC 210.63. Q <br /> COORDINATE LOCATION OF DISCONNECT SWITCH WITH MECHANICAL VENDOR PRIOR TO INSTALLATION. PROVIDE <br /> ® O FLEXTITE CONDUIT BETWEEN DISCONNECT SWITCH AND TERMINATION POINT AT MECHANICAL UNIT. <br /> CU 5 <br /> A 0 0 ALL CONDUITS PENETRATION ON ROOF MUST BE COORDINATED WITH ARCHITECT. PROVIDE FLASHING AND Q <br /> COUNTER FLASHING AND WATER TIGHT ALL CONDUITS PENETRATION ON ROOF. RUN ALL CONDUITS IN GROUP <br /> 8 AND WELL ORGANIZED MANNER. _ <br /> ® RUN FEEDER AND BRANCH CIRCUIT WIRING ON ROOF ALONG MECHANICAL PATH. PROVIDE ROOF SLIPPERS <br /> o 30A 30ACLF <br /> 3R <br /> MA 3R FOR PROPER CONDUIT SUPPORTS AND INSTALLATION. <br /> 3P <br /> o F G PROVIDE RIGID STEEL PVC COATED CONDUIT INCLUDING FITTINGS ON ALL CONDUITS ON ROOF AND EXTERIOR LU <br /> C B-7,9,11 O INSTALLATION. _J <br /> 1 L1J <br /> 6 REFER TO SHEET E5.1 FOR THE MAXIMUM ALLOWED FEEDER LENGTH AND SIZE OF ELECTRICAL EQUIPMENTS. <br /> Al-8 <br /> WP AC <br /> GFCI O <br /> O <br /> CU WP 60A 60ACLF <br /> NEMA 3R 3P <br /> G <br /> ® B-1 ,3,5 <br /> CU 2 NOTE:ALL HVAC UNITS AND <br /> OTHER MECHANICAL EQUIPMENT <br /> SHALL BE SCREENED FROM PUBLIC <br /> VIEW AND ADJACENT PROPERTIES <br /> IF NEEDED. <br /> (CONSTRUCTION TO BE <br /> ONSIMILAR TO BUILDING) 0 <br /> o <br /> CU I Jam <br /> CLI o <br /> (E)CAR WA511 <br /> � - = z Ln <br /> z U <br /> U <br /> z z w U <br /> zz z � z <br /> zw 0 <br /> o =) It L <br /> 0 U <br /> zQ � o <br /> W <br /> • <br /> DATE <br /> 03/05/2020 <br /> SCALE <br /> A5 5110WN <br /> DRAWN <br /> GEA <br /> ELECTRICAL ROOF PLAN a3 4 5 6 JOB <br /> E3.1 SCALE: 1/8"=1'-0" SHEET <br />