REVISIONS BY <br /> GENERAL NOTES <br /> A. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL PIPING <br /> AND UTILITIES PRIOR TO START OF WORK. IN THE EVENT OF ANY <br /> 3" SD T B 3" SD T B 3" SD T B 3" SD T B 3" SD T B 3" SD T B DISCREPANCIES OR POTENTIAL CONFLICTS, NOTIFY THE ARCHITECT <br /> ROOF DRAIN OVERFLOW ROOF DRAIN OVERFLOW OVERFLOW ROOF DRAIN AND ENGINEER IN WRITING PRIOR TO START OF WORK. <br /> A=664FT2 A=664FT2 A=664FT2 <br /> NORTH _ _ B. ALL PIPING LOCATIONS ARE DIAGRAMMATIC. CONTRACTOR SHALL <br /> OFTD RD OF RD OF OF D COORDINATE WITH ALL TRADES AND OWNER'S REPRESENTATIVE AND <br /> VERIFY EXACT ROUTING PRIOR TO START OF WORK. <br /> PAR PET WALL i� C. ALL SEWER PIPE SHALL BE SLOPED TO 1/4" PER FOOT. <br /> 3 <br /> FREE DISCHARGE UNLESS OTHERWISE NOTED. <br /> 1'AFF D. PIPE PENETRATIONS OF FIRE RATED WALL, FLOOR & CEILING SHALL <br /> NORTHERN BE PROTECTED AS PER CBC 714.3. <br /> LOWER ROOF 0- PARAPET WALL 4 <br /> NORTHERN DECK E. VENT PIPING SHALL BE AT CEILING SPACE OR HIGH LEVEL. <br /> UPPER ROOF A=1110FT2 w z UNLESS OTHERWISE NOTED. <br /> DECK <br /> A=285FT2 uN F. WASTE PIPING BELOW THE FLOOR OR GROUND. UNLESS <br /> – OTHERWISE NOTED. <br /> ORTHERN N Q�pFESS/pA <br /> oN, �,n, UPPER ,PAPE <br /> RP ROOF <br /> A=595FT2 SHEET NOTES �' M36488 m <br /> Exp.09/30/21 A <br /> PARAPET WALL <br /> � F Q <br /> Q <br /> ~ F CAL <br /> 01 3/4"CW PIPE FROM BELOW THRU ROOF FOR HOSE BIBB. <br /> OU ER FAUCET SHALL HAVE INTEGRAL ASSE 1011 COMPLIANT <br /> UPPER VACUUM BREAKER. <br /> ROOF o o <br /> A=595FT2 0 3/4" DRAIN FROM ROOF TOP UNIT TO DISCHARGE TO ROOF <br /> 1 <br /> DRAIN AS PER APPROVAL OF THE AUTHORITY HAVING m <br /> HB 2 i JURISDICTION. <br /> 3 4" VENT THROUGH ROOF. PROVIDE ROOF CAP WITH INSECT 0 <br /> —3/4"7 O SCREEN. m v L <br /> E <br /> 04 3" VENT THROUGH ROOF. PROVIDE ROOF CAP WITH INSECT Z <br /> SCREEN. Z <br /> OF RTU 2 <br /> sD 3 <br /> RD 3' P WALL °� 3 <br /> SOUTH N <br /> rD UPPER ROOF <br /> FREE DISCHARGE <br /> DECK <br /> 4" SD T B knocK 1 AFF A=285FT2 <br /> ROOF DRAIN 0 z <br /> V) <br /> A=1990FT2 U 4 Q <br /> i <br /> z <br /> O <br /> 4" SID TB 2 <br /> OVERFLOW N <br /> 1 I <br /> I <br /> o ® RTU 1 <br /> I ^ 3 <br /> 01 <br /> J <br /> D � <br /> N <br /> _I >no z }- <br /> o � <br /> Z N <br /> n <br /> o Lj iCL- J <br /> Li- I <br /> � <br /> oI QD <br /> on-i o CU 2 LL_ <br /> U) N SOUTHERN UNITS AND O <br /> N LOWER ROOFL EQUIPMENT O <br /> DECK ) FROM PUBLIC CQ <br /> A=1 1 10FT2 T PROPERTIES <br /> D Ir DED. LL <br /> V) �u�VSTKu�-TION TO BE <br /> SIMILAR TO BUILDING) <br /> I <br /> OF N <br /> RDI CL- <br /> Li I <br /> 0 <br /> IV) <br /> PARAPET WALL <br /> (E) CAR WASf1 <br /> 0 <br /> IN <br /> SLOPE <br /> 1/2 : 12 MIN. TYP. <br /> 0 <br /> IN <br /> in <br /> C O O <br /> ou-j W N <br /> v7 J = z Ln <br /> 6� <br /> U c ) <br /> 4 Lu `L w U <br /> zQ <br /> I w z <br /> N zw z � o <br /> N z Q <br /> 0 <br /> OF N <br /> D ROOF ACCESS <br /> PARAPET WALL <br /> LLI <br /> DATE <br /> 03/05/2020 <br /> SCALE <br /> AS SHOWN <br /> DRAWN <br /> GEA <br /> JOB <br /> ROOF PLAN - PLUMBING LAYOUT <br /> SHEET <br /> P2.5 3/16" = 1 '-0" F) 2 ,o 5 <br />