Laserfiche WebLink
REV 1510NS BY <br /> ET WATER HAMMER <br /> ARRESTOR <br /> HOT OR COLD WATER SUPPLY TYP. FLOOR SINK W/ EXPANSION TANK. <br /> DOME STRAINER SIZE AND INSTALL AS HOT WATER SUPPLY <br /> IF BRANCH IS GREATER THAN 20' LONG, PROVIDE PER MFR.'S <br /> t t <br /> ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF RECOMMENDATIONS. ° THERMOMETER <br /> 't THE FIXTURE UNITSPROVIDE SEISMIC <br /> PDI SIZE A1/2 GRATE W/OPEN <br /> CRIMP EDGE OVER PIPE O - -- <br /> IN A NEAT MANNER TO 0-111 FOR DRAIN PIPES STRAPS AS PER CPC. ° ° ---1 <br /> PREVENT REDUCTION OF SET ON TOP OF FLOOR _ <br /> IF HORIZONTAL BRANCH IS LESS SINK i <br /> THAN 20' LONG, PROVIDE ONE EFFECTIVE VENT AREA. EDGE OF EQUIPMENT COLD WATER i <br /> WHA AT END OF LINE TOP VIEW SUPPLY <br /> 1 _ <br /> SINGLE FIXTURE MULTIPLE FIXTURES SHEET COPPER OR LEAD FLOOR SINK PROVIDE HALF SIZE WATER HAMMER <br /> PDI PIPE FIXTURE FIXTURE UNIT TABULATION COUNTER FLASHING BY PLBG. REMOVABLE GRATE REMOVABLE GRATING ARRESTOR <br /> SIZE SIZE UNIT LOAD FIXTURE COLD HOT BASE FLASHING CONT'R. (TO MATCH MATERIAL OF FOR CLEANING INDIRECT o <br /> A 1/2" 1-11 VALVE WATER CLOSET 10 -- BY GEN'L. BASE FLASHING). OF DOME STRAINER DRAIN PIPE <br /> B 3/4" 12-32 TANK WATER CLOSET 5 -- CONT'R. 1 " ABOVE AS.M.E. APPROVED <br /> C 1" 33-60 URINAL 5 __ FINISH FLOOR + FINISH FLOOR (3) 1 -1/4" x 1/8" WH o PRESSURE AND <br /> STEEL STRAPS ONE AT TEMPERATURE RELIEF QkoFESS/pN <br /> D 1-1/4" 61-113 LAVATORY/SINK 1.5 1.5 THE UPPER (1/3) AND ' VALVE <br /> y <br /> � � 2 <br /> > OTHER AT LOWER <br /> E 1-1/2 114-154 JANITORS SINK 3 3 ° DRAIN VALVE. z <br /> F 2" 154-330 SHOWER/BATHTUB 2 2 <br /> (1/3) <br /> OF ITS DIMENSIONS VERTICAL DISCHARGE TO ui �' M36409 80 A <br /> LOOR SINK LOWER POINT, A MIN APPROVED DRAIN p <br /> IM FLUSH TYPE FIXTURE AT MIN. 1 " <br /> [ REFER TO ARCH. - ( ) DISTANCE OF 4" SHALL <br /> NOTES: REFER TO PLANS 0 AIR GAP ABOVE Q <br /> DWGS. FOR ROOF CONSTRUCTION. BE MAINTAINED ABOVE <br /> FOR SIZE AND WASTE LINE THE CONTROLS WITH ° FIXTURE RIM. n FCA <br /> 1. PROVIDE AIR CHAMBERS OR WATER HAMMER ARRESTERS BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, LOCATION THE STRAPPING. IDISCHARGE TO <br /> WATTS OR APPROVED EQUIVALENT WITH PISTON AND 0-RING CONSTRUCTION, HAVING PDI #WH-201, ASSE # 1010 STRAPS SHALL BE APPROVED DRAIN <br /> AND ANSI # A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. SECTION ANCHORED TO WALL FIXTURE AT MIN. 1" o <br /> INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND/OR WITH 3/8" x 3" LAG AIR GAP ABOVE <br /> PER THE TABLES SHOWN ABOVE. BOLTS OR APPROVED FIXTURE RIM. N c� <br /> 2. INSTALL PER PDI STANDARDS AND MANUFACTURER'S INSTRUCTIONS. EQUAL. N m <br /> PLATFORM WITH j W <br /> DRIP PAN <br /> 0 <br /> WATER HAMMER ARRESTOR ASSEMBLY DETAIL NTS 10 VENT THRU ROOF DETAIL NTS 7 FLOOR SINK DETAIL NTS 4 STORAGE TYPE WATER HEATER PIPING DETAIL NTS 1 <br /> 3 <br /> � 3 <br /> VACUUM RELIEF VALVE COLD WATER PIPE <br /> DOMESTIC STAINLESS STEEL IN ACCORDANCE WITH HOT WATER PIPE <br /> WATER LINE ACCESS PANEL CSA Z21 .22 <br /> z <br /> SHUT-OFF VALVE \i <br /> 1/2" TRAP PRIMER SUPPLY i <br /> MAY EXTEND AS MOO TRV TO <br /> P SINK. �\ 0 <br /> A WASTE OR A <br /> VENT LINE T <br /> WALLCOVER AND <br /> SCREW (FIRE 1 -1/4" x 1/8" STEEL T <br /> wH <br /> 0 STRAPS ONE AT THE i <br /> PROVIDE TRAP PRIMER VALVE RATED WHERE WALL UPPER (1/3) AND <br /> KEYED LOCK REQ D) i <br /> ---� PLUGGED TEE WITH OTHER AT LOWER <br /> CLEANOUT <br /> (1/3) OF ITS VERTICAL WALL STRUCTURE (� <br /> TYP. UNION DIMENSIONS. AT <br /> LOWER POINT, A MIN — <br /> BOTTOM PLATE DISTANCE OF 4" SHALL Q <br /> " <br /> 1 2TRAP PRIMER LINE FLOOR LINE BE MAINTAINED ABOVE <br /> / THE CONTROLS WITH Lf <br /> THE STRAPPING. Q <br /> i STRAPS SHALL BE 0 <br /> SLEEVE THRU FLOOR SLAB FLOOR DRAIN/FLOOR ANCHORED TO WALL ( n <br /> SLAB SINK � WITH 3/8" x 3" LAG o `J <br /> i BOLTS OR APPROVED z <br /> EQUAL. WALL MOUNTED CD <br /> 0 oa o o� p o BALANCE OF PIPING SAME ET SUPPORT PLATFORM <br /> AS CLEANOUT TO GRADE 2 DRAIN VALVE. <br /> WASTE PIPE EXPANSION TANK. DISCHARGE TO <br /> SIZE AND INSTALL AS APPROVED DRAIN D <br /> 1/2" HARD PER MFR.'S FIXTURE AT MIN. 1" __jDRAWN COPPER RECOMMENDATIONS. NOTE: AIR GAP ABOVE D_ <br /> & CONTINUOUS PROVIDE SEISMIC 1.) 6 MINIMUM FIXTURE RIM. <br /> WATER <br /> SLOPE STRAPS AS PER CPC. RENS ABOVE <br /> WATER HEATER. <br /> 2.) 7' CLEARANCE FROM <br /> TOP RIM OF MOP <br /> SINK. <br /> TRAP PRIMER DETAIL NTS 8 WALL CLEANOUT DETAIL NTS 5 NTS 12 <br /> z <br /> LAVATORY 0 <br /> rm LL/ <br /> � <br /> O O <br /> ..�..�..�..�..�.. FULL SIZE PIPE, VENT <br /> oN_ <br /> U <br /> U � < <br /> Lu LL_ <br /> w U <br /> MECHANICAL EQUIPMENT CLEANOUT AND ACCESS <br /> COVER. TOP OF COVER TO 1 O <br /> CONDENSATE DRAIN, z 'l' z O <br /> 2" HOT WATER LINE <br /> BE FLUSH WITH TOP OF / <br /> SIZE COLD WATER O U <br /> FLOOR. THERMOSTATIC LINE w O <br /> MIXING VALVE z Q �— <br /> � ��� � ��� � ��� � FLOOR LINE <br /> 3" MIN. <br /> SHUT OFF VALVE <br /> O <br /> TRAP <br /> 1/8" BEND <br /> rA DATE <br /> 03/05/2020 <br /> BALANCE OF PIPING SAME POU POINT OF USE <br /> AS CLEANOUT TO GRADE. � WATER HEATER SCALE <br /> NOTE: CONTRACTOR SHALL VERIFY EXACT SIZE AND LOCATION OF AS 5110WN <br /> ALL PLUMBING CONNECTIONS INTO MECHANICAL UNITS PRIOR J-BOX , BY <br /> TO START OF WORK. BRANCH PIPE SIZE SHALL NOT BE LESS BY ELECT. DRAWN <br /> THAN THE CONNECTION SIZE. GEA <br /> POWER WIRING BY JOB <br /> ELECT, <br /> NOTES: INSTANT WATER HEATER MOUNTING DETAILS AS PER MANUFACTURE RECOMMENDATION. SKEET <br /> POINT OF USE WATER HEATER DETAIL NTS 9 FLOOR CLEANOUT DETAIL NTS 16 POINT OF USE WATER HEATER DETAIL NTS 3 F)4 1 <br />