Laserfiche WebLink
Time In: <br /> Time Out: <br /> opQ.�tN. San Joaquin County <br /> .X Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> • �... P Telephone: (209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd <br /> �<<FORtN <br /> Underground Storage Tank Program Service Request Inspection Report <br /> Name of Facility: ARCO 07049 Date: 10/07/2019 <br /> Address: 800 E Kettleman LN , LODI 95240 <br /> Requestor: ALEXIA INIGUES, BARGHAUSEN CONSULTING ENGINEERS INC Telephone: (425)251-6222 <br /> Program Element: 2303-UST/PIPING INSTALLATION Request#: SR0078236 <br /> Inspection Type: 131 -UST INSTALLATION INSPECTION <br /> Onsite Service Technician: Latham Zubillaga ICC Service Tech/Installer Exp. Date: 01/08/2020 <br /> Manufacturer training: NOV, 01/16/20 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> On site for the following: <br /> -Witnessed pressure testing on the 87, 91, diesel,fill and STP sumps at 3 psi for one hour. All passed. <br /> -Verified proper brine manufacturer. <br /> -Verified brine filling was conducted in accordance with manufacturer instructions. Witnessed the addition of brine on sumps. <br /> -Verified secondary piping slope at 1/8 inch per foot or greater to a containment sump. <br /> -Verified all pipe setbacks, cross overs, and burial depth according to the manufacturer's installation instruction. *The chase <br /> piping between the vapor recovery manifold from the 91 tank to the 87 tank sump and the 91 product line sump crosses over <br /> the pipe with less than the required crossover distance. Both pipes were wrapped in thick rubber by the installer. Written <br /> manufacturer approval is needed for any alternative installation methods.. <br /> -Provide written approval for the wrapping of the piping prior to backfilling. <br /> *Additional inspections are needed. Refer to the approval letter for a list of required inspections.* <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Name and Title: Latham Zubillaga, Superintendent <br /> EH Specialist: SHEWIT WOLDEAREGAY Phone: (209)468-0216 <br /> FA0003633 SR0078236 SC131 10/07/2019 <br /> EHD 23-01 Rev.06/30/15 Page 1 of 1 Underground Storage Tank Program Service Request Inspection Report <br />