INSTALL_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
2300 - Underground Storage Tank Program
>
PR0231349
>
INSTALL_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 1:30:08 PM
Creation date
8/25/2020 4:25:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0231349
PE
2351
FACILITY_ID
FA0003633
FACILITY_NAME
ARCO 07049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
Ln
City
Lodi
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E Kettleman Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19204310.5 <br /> UNDERGROUND STORAGE TANK <br /> MONITORING SYSTEM CERTIFICATION FORM(Page t of 6) <br /> This form must be used to document testing and servicing of underground storage tank(UST)monitoring equipment. A copy <br /> of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local <br /> agency regulating the USTs within 30 days of the date of the monitoring system certification. <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Monitoring System Certification <br /> 10339507 1 11/27/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) Building# <br /> Arco 7049 <br /> Business Site Address City ZIP Code <br /> 800 E Kettleman Lane Lodi 195240 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of Company Performing the Certification Phone# <br /> Gettler-Ryan Inc. (925) 551-7555 <br /> Mailing Address <br /> 6805 Sierra Court, Suite G, Dublin, CA 94568 <br /> Name of UST Service Technician Performing the Certification(Print as shown on the ICC Certlfrcatlon) <br /> Elodio Sanchez <br /> Contractor!Tank Tester License# Certification# ICC Certification Expiration Date <br /> ICC <br /> 220793 8887127 6/4/2020 <br /> Mon1toring System Training and CerUficatlons List all applicable cerlifications. Expiration Date <br /> Veeder Root TLS3XXX Tech Ceti B41204 7/5/2020 <br /> VMI Line Leak#3200 12/3/2020 — <br /> VM I <br /> 2/3/2020VMI LDT-890 Leak Detector Tester#3201 12/3/2020 <br /> III. RESULTS OF TESTING 1 SERVICING <br /> Indicate and attach the following reports if the monitoring equipment is capable of generating either. Y N NA <br /> x Monitoring System Set-up x Alarm History Report <br /> Was any monitoring equipment replaced? Q <br /> (If'Yes,"Identify the specific devices replaced and list the manufacturer and model for all replacement parts In section IV below.) <br /> Was damage,debris,or liquid found inside any secondary containment systems? <br /> (If"Yes,'describe what was found in section IV below.) <br /> Is all monitoring equipment operational per manufacturer's specifications? <br /> (1t'No,"describe why in sactlon IV below.) N El El <br /> IV. COMMENTS <br /> ll directed to use this section,describe how and whop the Issues were or will be corrected. <br /> RECEIV <br /> DEC i, 7 Zoo <br /> ENVIRONMENTAL HEAF <br /> DEPARTS!,,FNT <br /> V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the equipment Identified In this document was inspected/serviced in accordance with California Code of <br /> Regulations,Title 23,Division 3,Chapter 16,Section 2638 and all Information contained herein Is true and accurate. Attached to <br /> this certification Is information(e.g.,manufactursUolchocklists,monitoring system set-up,alarm history report,etc.) necessary <br /> to verify that this Information and slte plana n th a out of UST system is complete and accurate. <br /> UST Service Technician Signature CAS&A <br /> CERS=C liibmia Ernironmental Reporting System,10-Identification,ICC=triftriatlorel Code Card,Y=Yes,N=No,NA=Not Appic" <br />
The URL can be used to link to this page
Your browser does not support the video tag.