My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2124
>
2200 - Hazardous Waste Program
>
PR0544381
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/26/2020 8:45:11 AM
Creation date
8/26/2020 7:57:26 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0544381
PE
2220
FACILITY_ID
FA0025229
FACILITY_NAME
CAVALLINO COACHWORKS OF STOCKTON
STREET_NUMBER
2124
Direction
W
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95203
CURRENT_STATUS
01
SITE_LOCATION
2124 W FREMONT ST
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Small Quantity Hazardous Waste Generator Inspection Report <br />Date: <br />July 17, 2019 <br /> Facility Address: <br /> 2124 W FREMONT ST, STOCKTON <br /> Facility Name: <br /> CAVALLINO COACHWORKS OF STOCKTON <br />Labeling and Storage <br /> 611 □ V □ R □ COSFailure of laboratory to comply with hazardous waste accumulation area requirementsHSC 25200.3.1(b) <br />Universal Waste <br /> 701 □ V □ R □ COSUW handler failed to notify EPA RA and obtain an EPA ID # prior to accumulating >5000kg of UWCCR 66273.32(a) <br /> 702 □ V □ R □ COSElectronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UWCCR 66273.32(c) <br /> 703 □ V □ R □ COSUW handler failed to store UW batteries in a manner that prevents release to the environmentCCR 66273.33(a) <br /> 704 □ V □ R □ COSUW handler failed to properly manage universal waste lampsCCR 66273.33(b) <br /> 705 □ V □ R □ COSUW handler failed to properly manage mercury containing universal wasteCCR 66273.33(c) <br /> 706 □ V □ R □ COSUW handler failed to prevent release of universal waste electronic devices, CRTs or CRT glassCCR 66273.33.5 <br /> 707 □ V □ R □ COSFailed to manage aerosol cans in a manner that prevents the unauthorized release of wasteHSC 25201.16(e) <br /> 708 □ V □ R □ COSFailed to properly manage containers of waste aerosol cansHSC 25201.16(f) <br /> 709 □ V □ R □ COSFailed to store used aerosol cans in an accumulation containerHSC 25201.16(g) <br /> 710 □ V □ R □ COSNo written operating procedure for aerosol can processingHSC 25201.16(h)(4) <br /> 711 □ V □ R □ COSFailed to submit or amend notification for aerosol can processingHSC 25201.16(j) <br /> 712 □ V □ R □ COSUW handler (UWH) failed to label universal waste to identify type of universal wasteCCR 66273.34 <br /> 713 □ V □ R □ COSUWH stored UW onsite greater than one year or was unable to demonstrate storage timeCCR 66273.35 <br /> 714 □ V □ R □ COSUWH failed to train employees and maintain records on UW handling and emergency proceduresCCR 66273.36 <br /> 715 □ V □ R □ COSUWH failed to keep complete records of each shipment of universal waste for three yearsCCR 66273.39 <br /> 716 □ V □ R □ COSUW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notificationCCR 66273.40(a)(3)(4) <br /> 717 □ V □ R □ COSUWH failed to obtain an ID number from DTSC prior to accumulating >5000kg of non-RCRA UWCCR 66273.32(b) <br /> 718 □ V □ R □ COSFailure of a UW handler to submit a complete annual report to DTSCCCR 66273.32(d) <br /> 719 □ V □ R □ COSFailure of UW handler to transfer UW to the appropriate destination facilityCCR 66273.38 <br /> 720 □ V □ R □ COSUW handler caused improper disposal of UWCCR 66273.31(a) <br /> 721 □ V □ R □ COSConditionally exempt small quantity UW generator caused improper disposal of UWCCR 66273.8(b) <br />Appliance Recycler <br /> 801 □ V □ R □ COSFailure to obtain Certified Appliance Recycler certification (CAR)HSC 25211.4 <br /> 802 □ V □ R □ COSFailure of a CAR to provide docs that materials that require special handling have been removedHSC 25211.2, 25211.3 <br /> 803 □ V □ R □ COSFailure of a CAR to properly remove and dispose of all materials that require special handlingHSC 25212 <br />Other Violations <br /> 3010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 3020 □ V □ R □ COSUnlisted Training violation See below <br /> 3030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 3040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 3050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />Page 3 of 4 <br />FA0025229 PR0544381 SC001 07/17/2019 <br />EHD 22-01 Rev. 09/27/2018 Small Quantity Hazardous Waste Generator OIR <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page