My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
141
>
2300 - Underground Storage Tank Program
>
PR0543574
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/23/2021 10:51:14 AM
Creation date
8/27/2020 2:37:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0543574
PE
2351
FACILITY_ID
FA0024750
FACILITY_NAME
Harney Lane 76
STREET_NUMBER
141
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
141 E HARNEY LN
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN O U I Environmental Health Department <br /> —_. — ........... C u a AMENDED <br /> Greatness grows here, 11/10/2020 <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> 76 FUEL ISLAND&CARWASH (916)807-4076 July 07, 2020 <br /> Facility Address: CERS ID: <br /> 141 E HARNEY LN, LODI, CA 95240 10844113 <br /> Inspection Contact: Title: Phone: <br /> Sandeep Dhanda TIManaging Member (209)518-3496 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 12351 - UST FACILITY-2481 COMPLIANT <br /> Consent For: Consent Given By: <br /> ❑x Inspection ❑x Photos ❑ Samples Balwinder Dhanda, Managing Member <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> Steven Jones 08/05/2021 <br /> Service Technician Manufacturer's Training: <br /> VR, 07/21/21; OPW, 01/16/21;VMI,07/01/20 <br /> CCR=Title 23 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284;CCR Failure to obtain a permit to operate from the EHD including but not limited to unpaid permit fees c V c R c COS <br /> 2711(d) <br /> 102 CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST c V c R c COS <br /> 103 CCR 2635(f),2636(c)(2) Failure to submit the UST Certification of Installation/Modification c V c R c COS <br /> 104 CCR 2632(d)(1), Failure to have an approved UST Monitoring Plan c V c R c COS <br /> 2634(d) <br /> 105 CCR 2632(d)(2), Failure to have an approved UST Response Plan c V c R c COS <br /> 2634(e) <br /> 106 CCR 2632(d),2641(h) Failure to submit and maintain a current facility plot plan/site map c V c R c COS <br /> 107 HSC 25292.2;CCR Failure to submit and maintain complete and current financial responsibility documents c V c R c COS <br /> 2711(a)(11) <br /> 108 CCR 2620(b);HSC Failure to implement or maintain a written agreement between the UST owner and operator c V c R c COS <br /> 25284(a)(3) <br /> 109 CCR 2715(a)(1)(B), Failure to submit"Designated Underground Storage Tank Operator Identification Form"within 30 days c V c R c COS <br /> 2715(a)(3) <br /> 110 CCR 2715(a)(1)(A), Failure to submit the"Underground Storage Tank Statement of Understanding and Compliance Form" c V c R c COS <br /> 2715(a)(2) <br /> 111 CCR 2637,2638(e), Failed to notify the EHD 48 hours prior to conducting testing c V c R c COS <br /> 2643(g) <br /> 112 CCR 2638,26410), Failure to have properly qualified service technician test leak detection equipment every 12 months c V c R c COS <br /> 2715(f) <br /> 113 CCR 2637(a-d),2712(b) Failure to conduct secondary containment testing c V c R c COS <br /> (1)(F) <br /> 114 CCR 2636(f)(3),2643(c) Failure to perform line integrity test every 12 months or within 30 days of repair of primary pipe c V c R c COS <br /> (3) <br /> 115 CCR 2638(c),2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the test c V c R c COS <br /> 116 CCR 2637.1(d), Failure to submit the"Spill Container Testing Report Form"within 30 days c V c R c COS <br /> 2637.1(e) <br /> 117 CCR 2637(e),2637(f) Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test c V c R c COS <br /> 118 CCR 2637.2(d&e), Failure to submit the"Overfill Prevention Equipment Inspection Report Form"within 30 days c V c R c COS <br /> 2665(a&b) <br /> 119 CCR 2663, 2712(b)(6) Failure to comply with tank lining certification,testing,and inspection requirements c V c R c COS <br /> 120 CCR 2631,2640.1, Failure to submit and/or maintain documentation regarding compatibility for UST system components c V c R c COS <br /> 2665,2711 <br /> FA0024750 PRO543574 SCO01 07/07/2020 <br /> EHD 23-01 Rev.9/16/2020 Page 1 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.