My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3233
>
1600 - Food Program
>
PR0546144
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2020 3:34:09 PM
Creation date
8/27/2020 3:24:59 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0546144
PE
1618
FACILITY_ID
FA0026105
FACILITY_NAME
DOLLAR TREE #08467
STREET_NUMBER
3233
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
3233 W HAMMER LN STE 1
P_LOCATION
01
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-Tr-e-e__ <br /> � �,ti9OAL �o <br /> Water Friendly Solutions `%ce le <br /> BARRIER-FREE UNIVERSAL SPLIT LEVEL VERSACOOLEe II <br /> Energy and Water Conservation Technology <br /> PG8ACSL, PGACSL <br /> Suggested Specification <br /> Model PG8ACSL shall deliver 8.0 gph of 50°F degree water at 90°F Options (at additional cost) <br /> ambient and 80°F inlet water.Model PGACSL is a non-refrigerated • Glass filters(factory installed) <br /> drinking fountain and delivers ambient water.Models PG8ACSL and • Push handle(029603-004) <br /> PGACSL shall include front and side antimicrobial copper push pads. • Push back(029603-005) <br /> Basin shall be designed to eliminate splashing and standing water. • Push down(029603-006) <br /> Water saver bubbler reduce waste water by 50%and shall have flexible • One piece chrome plated brass bubbler(036700-001) <br /> guard and operate between 20 and 100 PSI.Cabinet finish shall be • Apron for upper unit <br /> sandstone on galvanized steel or brushed stainless steel.Cooling system Limited 5-Year Warranty <br /> shall use R-134a refrigerant.Shall comply with ANSI 117.1 and ADA. (Continetal limits of the United States and Canada) <br /> Shall be listed by Underwriters Laboratories to US and Canadian Five years on the sealed refrigeration system and most <br /> standards.Shall comply with ANSI/NSF 61 and NSF/ANSI 372. component parts.Detailed watrantly certificate enclosed <br /> Models with each water cooler;sample avaiable upon request. <br /> • PG8ACSL delivers 8.0 gallons of chilled drinking water per hour amort Waranty <br /> • PGACSL is a non-refrigerated fountain One <br /> Standard Features One year on components parts.Detailed warranty <br /> certificate enclosed with each drinking fountain; <br /> • Universal design includes a universal side access panel and universal sample copy avaible upon request. <br /> drain pipe that allows the unit to be installed left high,right low or right Certifications/Compliance <br /> high,left low • Antimicrobial Copper-EPA Registration No.89187-3 <br /> • Built-in 100 micron strainer stops particles before they enter the . oasis International Electric Water Coolers are listed by <br /> • waterway <br /> • Waterways are Lead-Free in materials&construction Underwriters Laboratories Inc and comply with both U.S.and <br /> • Stainless steel top Canadian Requirements. <br /> • Flexible and one-piece water saver bubbler • Product Certified to NSF/ANSI Standard 61-G&372 and <br /> • Heavy duty galvanized steel frame conforms with the lead content requirements for"lead free" <br /> • Refrigerant R-134a plumbing as defined by California,Vermont,Maryland,and <br /> • Four antimicrobial copper push pads Louisiana state laws and the U.S.Safe Drinking Water Act. <br /> Finishes • This unit complies with ARI standard 1010 Testing, <br /> • Standard cabinet finish: Sandstone powder coated paint on Operating and Rating requirements(electric water coolers only). <br /> galvanized steel <br /> • Optional finishies(at additional cost): Stainless steel and These waters coolers comply with the requirements of ADA <br /> optional greystone powder coated paint (Americans with Disabilities Act)when properly installed. <br /> Installation 117 t <br /> • Prior to roughing consult with local,state and federal codes for proper a i <br /> mounting height �i3 ' OC&S <br /> • Shipped with complete instructions and wall mounting bracket <br /> • Removable side and front panels provide easy access for installation <br /> 50"1;Drinking Watur 115 volts, <br /> 0. <br /> r ;> <br /> - - - 0000::.:, <br /> F Ambient Air Temp HOLM Cold <br /> :.ti; <br /> PBAC•• 8.0 8.0 No No 1l4 4.6 460 Yes Yes 59 Lbs. <br /> PAC Fountain Only Yes 29 Lbe. <br /> * Industry Standard Rating Condition 800 F inlet water temperature Specifications subject to change without notice <br /> "'Special export models avaiable,operate on 220-240 volts,50/60 Hz <br />
The URL can be used to link to this page
Your browser does not support the video tag.