My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/23/2022 4:26:50 PM
Creation date
9/1/2020 9:40:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection ❑36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181313 11/21/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> LODI FOOD & LIQUOR <br /> Business Site Address City ZIP Code <br /> 1225 W. LOCKEFORD STREET LODI 95240 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Zane Nimmo (209) 744-0112 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 04-1676 Ex.03/31/2019 8883064-UT 6/1/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> FF- EBW, Phil-Tite &EVR Phase 1 10009843708 Ex 11-16-18 OPW 104-632 Ex 3-14-2020 <br /> Emco 3206 Ex. 9/21/2020 VR:A28446 ATG: 9/28/19 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines(Specify): <br /> Used: O P W PHASE I TESTING &SITE SPECIFIC TANK CHARTS <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages 4 <br /> TANK ID:(By tank number,stored product,etc.) 1 - 87 OCT 2 - 91 OCT 3 - DIESEL <br /> What is the tank inside diameter?(Inches) 95.5 95.5 95.5 <br /> Is the fill piping secondarily contained? ❑Yes [j]No ❑Yes 0 No ❑Yes ❑x No ❑Yes ❑ No <br /> Is the vent piping secondarily contained? 0 Yes ❑No 2 Yes ❑No 0 Yes ❑No ❑Yes ❑ No <br /> Overfill Prevention Equipment Manufacturer(s) opw oPw opw <br /> What is the overfill prevention equipment response ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> when activated? ❑x Restricts Flow Restricts Flow ❑x Restricts Flow ❑Restricts Flow <br /> (Check all that apply.) <br /> ❑AA/Alarm ❑A/V Alarm ❑A/V Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes Z No ❑Yes 2 No ❑Yes 0 No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 8911 8911 84.5" <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 96.7% 96.7% 93.2% <br /> Is the overfill prevention in proper operating condition ❑Yes ❑Yes 9e ❑Yes <br /> to respond when the substance reaches the <br /> appropriate level? Z No(Specify in V.) 0 No(Specify in V.) ❑No(Specify in V.) ❑ No(Specify in V) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ❑ Pass ❑x Fail 0 Pass ❑x Fail ❑x Pass ❑Fail ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> BOTH 87&91 DO NOT MEET STANDARDS REPAIR AND RETEST BY BZ. `. <br /> RE Rs ti 'i. <br /> a` .;' L <br /> 6 DQ '. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with lifornia Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurkiNVIRONMENTAL <br /> UST Service Technician Signature DEPARTMENT <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,A/V=Audible and Usual <br />
The URL can be used to link to this page
Your browser does not support the video tag.