My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/6/2022 4:29:57 PM
Creation date
9/1/2020 9:46:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (SPEEDWAY) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Page 1 of 6) <br /> Type of Action ❑ Installation Test ❑ Repair Test ❑Six Month Test ® 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181447 12/9/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business A3 " <br /> Speedway/Mobil 4681 <br /> Business Site Address City ZIP Code <br /> 2500 W. Lodi ENVIRONMENTAL HEALT Lodi 95242 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Michael McCarter (707)545-5522 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Able Maintenance, Inc.-312844 8819839 10/15/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (By tank number, stored product, etc.) A 87 B 89 C 91 D Diesel <br /> Tank Containment <br /> Tightness Test Result Z Pass ❑ Fail ❑ NA Z Pass ❑Fail ❑ NA Z Pass ❑ Fail ❑ NA Z Pass ❑ Fail ❑ NA <br /> Product Piping Containment <br /> Tightness Test Result ❑ Pass Z Fail ❑ NA ❑Pass Z Fail ❑ NA ❑Pass Z Fail ❑ NA Z Pass ❑ Fail ❑ NA <br /> Communication Test Result ❑ Pass Z Fail ❑ NA ❑ Pass Z Fail ❑ NA ❑ Pass Z Fail ❑ NA Z Pass ❑ Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑ Pass ❑Fail Z NA ❑ Pass ❑ Fail Z NA <br /> Communication Test Result ❑Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑Pass ❑Fail Z NA ❑ Pass ❑ Fail Z NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA <br /> Communication Test Result ❑ Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA ❑Pass ❑ Fail Z NA ❑ Pass ❑ Fail Z NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑ Pass ❑Fail Z NA ❑ Pass ❑ Fail Z NA ❑Pass ❑ Fail Z NA ❑ Pass ❑Fail Z NA <br /> Communication Test Result ❑ Pass ❑Fail Z NA ❑ Pass ❑Fail Z NA ❑Pass ❑ Fail Z NA ❑ Pass ❑Fail Z NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result Z Pass ❑ Fail ❑ NA Z Pass ❑ Fail ❑ NA Z Pass ❑ Fail ❑ NA ❑ Pass Z Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result Z Pass ❑Fail ❑ NA Z Pass ❑ Fail ❑ NA 2 Pass ❑ Fail ❑ NA Z Pass ❑Fail ❑ NA <br /> VENT/TRANSITION SUMP ID: a b C d <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑ NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑Fail ❑ NA <br /> UDC ID: 1 1/2 23/4 35/6 47/8 <br /> Tightness Test Result ❑ Pass Z Fail ❑ NA ❑ Pass Z Fail ❑ NA ❑Pass Z Fail ❑ NA Z Pass ❑ Fail ❑ NA <br /> UDC ID: 59/10 611/12 7 8 <br /> Tightness Test Result Z Pass ❑ Fail ❑ NA Z Pass ❑ Fail ❑ NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑Fail ❑ NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑ Pass ❑ Fail ❑ NA ❑ Pass ❑ Fail ❑ NA ❑Pass ❑ Fail ❑ NA ❑ Pass ❑Fail ❑ NA <br /> All items marked"Fail"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3 Chapter 16,Section 2637 and all the information contained herein is accurate. <br /> UST Service Technician Signature _. <br /> CERS=California Environmental Reporting System,ID=Identificabon,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment <br />
The URL can be used to link to this page
Your browser does not support the video tag.