My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/1/2020 10:29:08 AM
Creation date
9/1/2020 10:01:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br /> - C G U N T Y ....__.-. <br /> MINIMUM <br /> �� <br /> x, .. .x' .1 . �.r�:t .Ji �'91S,t�' .,�, :, a m, -r'.. i ��t,t <i£c7i ? ua' . �.,�� �f � .�t� �. t_ � 1# . ��s � ���2 .. , ' *��' *�1= ..� t��--k" =�� ;��� -r`',• Y..}itf j�.#��.. <br /> Facility Name: Facility Address: Date: <br /> E F KLUDT & SONS INC 1126 E PINE ST, LODI February 05, 2019 <br /> Item # Remarks <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br /> UST Tank Information forms for the racing fuel and Kerosene are not current In CERS. Both tanks state to be steel <br /> for primary containment and Jacketed as secondary containment however based on the service technician <br /> statement and observations the tanks have secondary containment to be Steel. Any change of information must be <br /> updated in CERS within 30 days of the changes. Immediately log into CERS , update the required information , and <br /> submit for review by the EHD. <br /> This is a Class II violation. <br /> 201 CCR 2712 (b) Failure to maintain monitoring , maintenance, and follow up action records . <br /> Maintenance and monitoring records for the last three years were not found on site. Monitoring system certification <br /> for 2017 were not available for review at the time of inspection , These records shall be maintained on site for at <br /> least three years, Monitoring records include: ( 1 ) date and time of all monitoring or sampling ; (2) monitoring <br /> equipment calibration and maintenance records; (3) results of any visual observations; (4) results of sample analysis <br /> performed a lab or in the field ; (5) logs of all readings of gauges or other monitoring equipment, ground water <br /> elevations , or other test results ; (6) results of inventory readings and reconciliations . The operator was able to get <br /> the test results emailed while the inspector was on site to correct the violation with inspector on site, <br /> This was corrected on site , <br /> This is a minor violation . <br /> 209 CCR 2716(a-e) Failure to conduct the designated UST operator visual inspection at least once every 30 days , <br /> In the March 1st, 2018 inspection report the DO failed to print the alarm history for 0- UDC 11 /12. <br /> In the June 4th , 2018 inspection report the DO failed to print the alarm history for L4- UDC 13/14, <br /> In the September 4th , 2018 inspection report the DO failed to print the alarm history for L13- Dyed Diesel 1 STP. <br /> In the December 6th , 2018 inspection report the DO failed to print the alarm history for L14- Dyed Diesel 2 STP, <br /> The DO failed to sign the Designated inspection report on 12/6/18, 1 /4/19 and 2/1 /19 . The DO was present at the <br /> time of inspection and was able to sign the reports to correct this part of the violation while the inspector was on site. <br /> During the monthly inspection , the designated operator shall review the alarm history for the previous month , check <br /> that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br /> documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br /> inspections at least once every 30 days at this facility and are including all of the required information on the reports . <br /> This is a repeat violation , Class II , <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity , <br /> Pig mats were observed in UDC SAT 9 , UDC 7/8 , UDC 9/10, UDC 11 /12 , and UDC 13/14 preventing the UDC <br /> sensor to detect a leak at the earliest opportunity, Monitoring equipment shall be maintained to be able to detect a <br /> leak at the earliest possible opportunity. The pig mats were removed by the service technician while the inspector <br /> was on site. Ensure that all monitoring equipment is maintained to detect a leak at the earliest opportunity . <br /> This is a Class II violation. <br /> PA0003771 PRO231364 SCO01 02/05/2019 <br /> EHD 23-01 Rev, 09/28/2018 Page 4 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 T 209 468-3420 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.