Laserfiche WebLink
SAN J O A Q U I N Environmental Health Department <br />COUNTY <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />A ONE GAS & FOOD <br />Facility Address: <br />574 W GRANT LINE RD, TRACY <br />Date: <br />December 31, <br />2018 <br />UST System Observations <br />314 <br />HSC 25290.1, 25290.2, <br />25291 <br />Failed to have secondary containment or secondary containment not tight <br />❑ V <br />❑ R <br />❑ COS <br />315 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) <br />D V <br />D R <br />D COS <br />316 <br />HSC 25290.1(c3), <br />25290.2(c3) <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) <br />D V <br />o R <br />D COS <br />317 <br />CCR 2636, 2643(c)(1), <br />2666(f) <br />Line leak detector (LLD) not installed <br />D V <br />D R <br />D COS <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch <br />D V <br />D R <br />D COS <br />319 <br />CCR 2635, 2637. 1. <br />2665, 2712 <br />No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tested <br />D V <br />D R <br />D COS <br />320 <br />CCR 2635, 2637.2,Failure <br />2665, 2712 <br />to comply with the installation, inspection, or record keeping of the overfill prevention <br />■ V <br />D R <br />■ COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />D V <br />D R <br />D COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />D V <br />D R <br />D COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />D V <br />D R <br />D COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />D V <br />D R <br />D COS <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />D V <br />D R <br />D COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />D V <br />D R <br />D COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />D V <br />D R <br />D COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />D V <br />D R <br />D COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />D V <br />D R <br />D COS <br />330 <br />CCR 2636(f), 2666(c), <br />2666(f) <br />No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm <br />D V <br />D R <br />D COS <br />331 <br />CCR 2630(d), 2641(a) <br />Liquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot). <br />D V <br />D R <br />D COS <br />332 <br />CCR 2631(b&d), <br />2666(b&e) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />D V <br />D R <br />D COS <br />333 <br />CCR 2635, 2636(b), <br />2662, 2712 <br />Failure to comply with the cathodic protection system requirements <br />D V <br />D R <br />D COS <br />334 <br />CCR 2666(b)(2) <br />Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair <br />D V <br />D R <br />D COS <br />335 <br />JCCR2630,2632,2643, <br />2644.1 <br />Equipment or methods used to monitor the UST system are not certified by an independent third-party <br />D V <br />D R <br />D COS <br />Single-Walled Non-Pressurized Piping <br />401 <br />CCR 2636(a)(3), <br />2641(b) <br />Suction piping not properly sloped or incorrectly located check valve <br />V <br />; R <br />❑ COS <br />402 <br />CCR 2643(d) <br />No monitoring or record maintenance for single-walled conventional suction systems (pre-Jan 1984). <br />D V <br />D R <br />D COS <br />403 <br />CCR 2643(d), 2661(f) <br />Failure to conduct 0.1 gph test for single-walled conventional suction systems (pre-Jan 1984) <br />D V <br />D R <br />D COS <br />404 <br />CCR 2643(e), 2661(f) <br />Biennial 0.1 gph line integrity test for single-walled gravity piping not performed (pre-Jan 1984) <br />D V <br />D R <br />- COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />D V <br />D R <br />D COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS ll, or MINOR - Notice to Comply) <br />FA0003164 PR0231405 SCO01 12/31/2018 <br />EHD 23-01 Rev. 09/28/2018 Page 3 of 7 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, Califomia 952051 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />