Laserfiche WebLink
SAN , J O A Q U I N Environmental Health Department <br />-COUNTY— <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />A ONE GAS & FOOD <br />574 W GRANT LINE RD, TRACY <br />December 31, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />inspections at least once every 30 days at this facility and are including all of the required information on the reports. <br />This is a Class II violation. <br />211 <br />CCR 2715(c)(2) No employee present that were trained in the operation and maintenance of the UST system by a <br />DO. <br />The designated operator employee training for Kevin Hur was not performed using the correct form. The designated <br />operator shall train facility employees for which he or she is responsible in the proper operation andmaintenance of <br />the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the designated operator, maintain the list on site, and submit a copy of <br />the training records to the EHD. <br />Training performed after October 1st, 2018 shall be recorder using the UNDERGROUND STORAGE TANK <br />FACILITY EMPLOYEE TRAINING CERTIFICATE found in title 23 chapter 16 appendix XII. <br />This is a repeat violation, Class II. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The site has flexible primary and secondary piping. During the field inspection it was observed that the test boots <br />appeared completely sealed with jumper hoses in the 87 product and 91 product lines in all UDCs. Any potential <br />release from the primary containment into the secondary containment in the 87 product and 91 product piping does <br />not flow into a UDC collection sump to detect a leak at the earliest opportunity. Immediately contact a properly <br />licensed, trained, and certified contractor to ensure that any releases in the 87 product and 91 product piping flows <br />into the nearest sump for a leak to be detected at the earliest possible opportunity. Ensure that all monitoring <br />equipment is maintained to detect a leak at the earliest opportunity. <br />This is a repeat violation, Class II. <br />FA0003164 PR0231405 SCO01 12/31/2018 <br />EHD 23-01 Rev, 09/28/2018 Page 6 of 7 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />