Laserfiche WebLink
SAN ,dDAQ U I N Environmental Health Department <br /> C0uNTY <br /> Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SPEEDCO#944 1 1515 HOFF DR, RIPON August 28, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> oil filters were handled. Copies of bills of lading shall be kept for a period of three years. <br /> CORRECTIVE ACTION: Immediately drain all metal oil filters of free-flowing oil, store them in closed, rainproof <br /> containers, label the container with the words"drained used oil filters,"and mark the container with an accumulation <br /> start date. Immediately obtain all missing bill of lading recycling records that can be found. Dispose of all used oil <br /> filters stored on-site greater than one year. Used oil filters not stored, handled and disposed of according to this <br /> section are regulated as hazardous waste. Provide a corrective action statement, disposal records and supporting <br /> documentation to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by [DATE, 30 days from now] . <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> Documents provided during inspection: Return to compliance certification, hazardous waste minimum labeling <br /> requirements sheet, Daily tank inspections log, free cupa classes flier <br /> Waste streams found: used oil, used paper oil filters, used metal oil filters, soiled rags, <br /> The following minor violations were corrected on site: <br /> OBSERVATION: The contingency plan reviewed on-site is out-of-date. The out-of-date sections are: <br /> The Primary Emergency Coordinator is listed as Jose Montes, Jose no longer works for this company. Operator <br /> updated contact information to include his name. <br /> REGULATION GUIDANCE: <br /> The contingency plan shall be reviewed, and immediately amended, if necessary, whenever: <br /> (a)applicable regulations are revised; <br /> (b)the plan fails in an emergency; <br /> (c)the facility changes in its design, construction, operation, maintenance, or other circumstances in a way that <br /> materially increases the potential for fires, explosions, or releases of hazardous waste or hazardous waste <br /> constituents, or changes the response necessary in an emergency; <br /> (d)the list of emergency coordinators changes; or <br /> (e)the list of emergency equipment changes. <br /> FA0017929 PR0538579 SCO01 08/28/2020 <br /> EHD 22-02 Rev.8/11/2020 Page 12 of 13 Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />