My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3725
>
2300 - Underground Storage Tank Program
>
PR0231417
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/13/2024 11:07:00 AM
Creation date
9/1/2020 3:45:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231417
PE
2361
FACILITY_ID
FA0003780
FACILITY_NAME
TRACY SHELL
STREET_NUMBER
3725
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21217030
CURRENT_STATUS
01
SITE_LOCATION
3725 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> APPENDIX <br /> SAMPLE TEST DATA SHEETS <br /> Appendix C contains sample test data sheets that can be used when conducting testing and verification of spill, over- <br /> fill,leak detection and secondary containment equipment,shear valves and emergency stops at underground storage <br /> tank(UST)facilities. Electronic versions of the forms also are available at www.pei.org/rpl200. <br /> Appendix C(pages 46- 56)contains the following data sheets: <br /> • Appendix C-1: Tank Secondary Containment Integrity Testing Dry Test Method <br /> • Appendix C-2: Piping Secondary Containment Integrity Testing <br /> • Appendix C-3: Spill Bucket Integrity Testing Hydrostatic Test Method Single-and Double-Walled <br /> Vacuum Test Method <br /> • Appendix C-4: Containment Sump Integrity Testing Hydrostatic Testing Method <br /> • Appendix C-5: UST Overfill Equipment Inspection Automatic Shutoff Device and Ball Float Valve <br /> • Appendix C-6: Overfill Alarm Operation Inspection <br /> • Appendix C-7: Automatic Tank Gauge Operation Inspection <br /> • Appendix C-8: Liquid Sensor Functionality Testing <br /> • Appendix C-9: Mechanical and Electronic Line Leak Detectors Performance Tests <br /> • Appendix C-10: Shear Valve Operation Inspection <br /> • Appendix C-11: Emergency Stop Switch Operation Inspection <br /> I <br /> f <br /> RECD VE D <br /> MAY 02 2019 <br /> i <br /> ENVIRONMENTAL HEALTH <br /> DEPARTMENT <br /> M <br /> pei.org <br />