Laserfiche WebLink
SAN J O A g U I N Environmental Health Department <br /> CC LJ N T Y------- <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> METAL FINISHING SOLUTIONS-STOCKTON 1 1325 EL PINAL DR, STOCKTON August 31, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> (4) If the source of the release was a leak to the environment from a component of a tank system without secondary <br /> containment,the owner/operator shall provide the component of the system from which the leak occurred with <br /> secondary containment that satisfies the requirements of section 66265.193 before it can be returned to service, <br /> unless the source of the leak is an aboveground portion of a tank system. If the source is an aboveground <br /> component that can be inspected visually,the component shall be repaired and may be returned to service without <br /> secondary containment as long as the requirements of subsection (g)of this section are satisfied. If a component is <br /> replaced to comply with the requirements of this subsection,that component shall satisfy the requirements for new <br /> tank systems or components in sections 66265.192 and 66265.193.Additionally, if a leak has occurred in any <br /> portion of a tank system component that is not readily accessible for visual inspection (e.g.,the bottom of an <br /> inground or onground tank), the entire component shall be provided with secondary containment in accordance with <br /> section 66265.193 prior to being returned to use. <br /> (g)Certification of major repairs. If the owner or operator has repaired a tank system in accordance with subsection <br /> (f)of this section, and the repair has been extensive(e.g., installation of an internal liner; repair of a ruptured <br /> primary containment or secondary containment vessel), the tank system shall not be returned to service unless the <br /> owner/operator has obtained a certification by an independent, qualified, professional engineer, registered in <br /> California, in accordance with section 66270.11(d),that the repaired system is capable of handling hazardous <br /> wastes without release for the intended life of the system. This certification shall be submitted to the Department <br /> within seven days after returning the tank system to use. <br /> CORRECTIVE ACTION: Immediately fix the leaking pump. Provide a corrective action statement and supporting <br /> documentation to the San Joaquin County Environmental Health Department(EHD)within 30 days. <br /> This is a Class II violation. <br /> 605 CCR 66262.34(f) Failed to completely label containers or portable tanks of hazardous waste. <br /> OBSERVATION: Hazardous waste containers were observed on-site with incomplete labeling. The containers <br /> were: <br /> -One white plastic 275 gallon tote of waste aluminum filters was observed east of the process line without <br /> hazardous properties on the label. <br /> REGULATION GUIDANCE: All hazardous waste containers shall be marked with the following information: the <br /> words"Hazardous Waste", name and address of generator, hazardous properties, physical state, composition <br /> (contents), accumulation start date <br /> CORRECTIVE ACTION: Immediately label the containers as required for hazardous waste. Provide a corrective <br /> action statement and supporting documentation to the San Joaquin County Environmental Health Department <br /> (EHD)within 30 days. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. A complete report was <br /> finished on September 3, 2020 and replaces the initial checklist. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> FA0024706 PR0543517 SCO01 08/31/2020 <br /> EHD 22-03 Rev.9/20/2019 Page 16 of 17 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />