My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1325
>
2231-2238 – Tiered Permitting Program
>
PR0543720
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2021 11:39:23 AM
Creation date
9/1/2020 4:29:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0543720
PE
2231
FACILITY_ID
FA0024706
FACILITY_NAME
METAL FINISHING SOLUTIONS - STOCKTON CA
STREET_NUMBER
1325
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1325 EL PINAL DR STE 1
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
569
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J OAQ U I N Environmental Health Department <br /> COUNTY <br /> Iii <br /> Greotness grows here. <br /> Permit By Rule Treatment Facility Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> METAL FINISHING SOLUTIONS-STOCKTON CA (916)893-4731 August 31, 2020 <br /> Facility Address: CERS ID: <br /> 1325 EL PINAL DR, STOCKTON, CA 95205 10743571 <br /> Inspection Contact: Title: Phone: <br /> Corey Dehl General Manager (408)802-4977 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 12231 -HAZARDOUS WASTE PBR FACILITY <br /> Consent For: Consent Given By: <br /> ❑x Inspection ❑x Photos ❑x Samples I Corey Dehl, General Manager <br /> CCR=Title 22 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25201(a) Failed to obtain a permit to treat hazardous waste ❑V ❑R ❑COS <br /> 102 CCR 67450.2(b)(2) Failed to submit an onsite hazardous waste treatment notification ❑V ❑R ❑COS <br /> 103 CCR 67450.3(c)(2) Failed to submit an amended hazardous waste treatment notification ❑V ❑R ❑COS <br /> 104 CCR 67450.3(c)(1) Failed to submit an onsite annual hazardous waste treatment notification by January 1 ■V ❑R ❑COS <br /> 105 HSC 25404(e)(4) Failed to report program data electronically ❑V ❑R ❑COS <br /> 106 CCR 67450.13(a)(1) Failed to submit the closure cost estimate and certification of financial assurance ❑V ❑R ❑COS <br /> 107 CCR 67450.13(a)(2) Failed to annually adjust the closure cost estimate and certification of financial assurance ■V ❑R ❑COS <br /> 108 CCR 67450.13(a)(3) Failed to revise the closure cost estimate and certification of financial assurance ❑V ❑R ❑COS <br /> 109 CCR 67450.3,67450.7 Failed to conduct and submit a phase one environmental assessment within one year ■V ❑R ❑COS <br /> 110 CCR 66265.77(a), Failed to submit a written incident report ❑V ❑R ❑COS <br /> 66265.560) <br /> 111 CCR 67450.3(c)(10) Failed to submit an annual report when requested ❑V ❑R ❑COS <br /> 112 CCR 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report ❑V ❑R ❑COS <br /> 113 CCR 67450.2(b)(3) Failed to submit correct PBR information in CERS ❑V ❑R ❑COS <br /> 114 HSC 25404.1.2 Failed to submit a certification and written response within 30 days for minor violations ❑V ❑R ❑COS <br /> On Site Records <br /> 201 CCR 67450.3(C)(9)(F) Failed to obtain a hazardous waste tank system assessment certified by a PE ❑V ❑R ❑COS <br /> 202 CCR 66265.191 Failed to annually certify an existing hazardous waste tank system without secondary containment ❑V ❑R ❑COS <br /> 203 CCR 67450.3(c)(9)(F) Failed to have a complete existing hazardous waste tank system assessment ❑V ❑R ❑COS <br /> 204 CCR 67450.3(c)(9)(F) Failed to have a complete new hazardous waste tank system assessment ■V ❑R ❑COS <br /> 205 CCR 67450.3(c)(9)(F) Failed to reassess the hazardous waste tank system every five years or service life of the system ❑V ❑R ❑COS <br /> 206 CCR 67450.3(c)(8) Failed to maintain documents for operating a fixed treatment unit onsite ■V ❑R ❑COS <br /> 207 CCR 67450.11(d)(7)(E) Failed to maintain records for cyanide treatment on site for three years ❑V ❑R ❑COS <br /> 208 CCR 67450.11(d)(4)(D) Failed to provide training for cyanide treatment ❑V ❑R ❑COS <br /> 209 CCR 67450.3(c)(9)(F) Failed to obtain CUPA approval prior to the replacement of a functionally equivalent tank ❑V ❑R ❑COS <br /> 210 CCR 67450.3(c)(9)(F) Failed to comply with hazardous waste tank system operating requirements ❑V ❑R ❑COS <br /> 211 CCR 67450.3(c)(9)(F) Failed to meet secondary containment requirements for hazardous waste tank systems ❑V ❑R ❑COS <br /> 212 CCR 67450.3(c)(8-9) Failed to prepare a treatment system inspection program and maintain inspection logs ■V ❑R ❑COS <br /> 213 CCR 67450.3(c)(8-11) Failed to prepare a closure plan,notify the CUPA of closure or submit a closure certification ■V ❑R ❑COS <br /> FA0024706 PR0543720 SCO01 08/31/2020 <br /> EHD 22-04 Rev.9/20/2019 Page 1 of 3 Permit By Rule Treatment Facility OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.