My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL PINAL
>
1325
>
2231-2238 – Tiered Permitting Program
>
PR0543720
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2021 11:39:23 AM
Creation date
9/1/2020 4:29:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0543720
PE
2231
FACILITY_ID
FA0024706
FACILITY_NAME
METAL FINISHING SOLUTIONS - STOCKTON CA
STREET_NUMBER
1325
STREET_NAME
EL PINAL
STREET_TYPE
DR
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
1325 EL PINAL DR STE 1
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
569
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A g U I N Environmental Health Department <br /> CC LJ N T Y------- <br /> Permit By Rule Treatment Facility Inspection Report <br /> Facility Name: Facility Address: Date: <br /> METAL FINISHING SOLUTIONS-STOCKTON 1 1325 EL PINAL DR, STOCKTON August 31, 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 204 CCR 67450.3(c)(9)(F)Failed to have a complete new hazardous waste tank system assessment. <br /> OBSERVATION: This hazardous waste treatment facility has hazardous waste tanks with incomplete tank <br /> assessments. <br /> -The PE certification statement is incomplete. Statement is missing'be"in"...to be the best of..." <br /> -Capacity of secondary containment, seismic calculations,wall thickness determination method, tank tightness test <br /> results, piping diameter and description of pumps are missing from the tank assessments for the 1500 gallon acid <br /> waste tank, 1500 gallon alkaline waste tank, 1000 gallon neutralization tank 1 and 1000 gallon neutralization tank 2. <br /> REGULATION GUIDANCE: Title 22 California Code of Regulations section 66265.192(a)-new tank systems <br /> Owners or operators of new tank systems or components shall ensure that the foundation, structural support, <br /> seams, connections, and pressure controls(if applicable)are adequately designed and that the tank system has <br /> sufficient structural strength, compatibility with the waste(s)to be transferred, stored or treated, and corrosion <br /> protection so that it will not collapse, rupture, or fail.The owner or operator shall obtain a written assessment <br /> reviewed and certified by an independent, qualified, professional engineer, registered in California in accordance <br /> with section 66270.11(d)attesting that the system has sufficient structural integrity, is acceptable for the <br /> transferring, storing and treating of hazardous waste, and that the tanks and containment system are suitably <br /> designed to achieve the requirements of this article. This assessment shall be obtained prior to placing the tank <br /> system in service, and shall be kept on file at the facility.This assessment shall also include, at a minimum,the <br /> following information: <br /> (1)design standard(s)according to which the tank(s)and ancillary equipment are or will be constructed; <br /> (2)hazardous characteristics of the waste(s)to be handled; <br /> (3)for new tank systems or components in which the external shell of a metal tank or any external metal component <br /> of the tank system is or will be in contact with the soil or with water, a determination by a corrosion expert of: <br /> (A)factors affecting the potential for corrosion, including but not limited to: <br /> 1. soil moisture content; <br /> 2. soil pH; <br /> 3. soil sulfides level; <br /> 4. soil resistivity; <br /> 5. structure to soil potential; <br /> 6. influence of nearby underground metal structures(e.g., piping); <br /> 7. stray electric current; and, <br /> 8. existing corrosion-protection measures(e.g., coating, cathodic protection), and <br /> (B)the type and degree of external corrosion protection that are needed to ensure the integrity of the tank system <br /> during the use of the tank system or component, consisting of one or more of the following: <br /> 1. corrosion-resistant materials of construction such as special alloys or fiberglass-reinforced plastic; <br /> 2. corrosion-resistant coating (such as epoxy or fiberglass)with cathodic protection (e.g., impressed current or <br /> sacrificial anodes); and <br /> 3. electrical isolation devices such as insulating joints and flanges; <br /> (4)for underground tank system components that are likely to be affected by vehicular traffic, a determination of <br /> design or operational measures that will protect the tank system against potential damage; and <br /> (5)design considerations to ensure that: <br /> (A)tank foundations will maintain the load of a full tank; <br /> (B)tank systems will be anchored to prevent flotation or dislodgement where the tank system is placed in a <br /> saturated zone, or is located within a seismic fault zone; and <br /> (C)tank systems will withstand the effects of frost heave. <br /> Title 22 California Code of Regulations section 66270.11 <br /> FA0024706 PR0543720 SCO01 08/31/2020 <br /> EHD 22-04 Rev.9/20/2019 Page 5 of 14 Permit By Rule Treatment Facility OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.